{"anchor":"openalex:W1511075954","by_predicate":{},"contesting_ideas":[],"elapsed_us":809,"energy_joules":0.014562,"supporting_ideas":[{"idea_id":"2ea1426c6673d8ae","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Cold spray is a solid state coating process that deposits powder particles at supersonic velocities below the melting point of the material.","t_start":1.0},{"idea_id":"22e296b50baeaf51","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"The basic principle of cold spray involves accelerating powder particles using a high-velocity gas jet to enable plastic deformation upon impact and formation of bonded splats.","t_start":1.0},{"idea_id":"2946731a8009809e","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Cold spray avoids high-temperature oxidation, evaporation, melting, crystallization, and residual stresses compared to traditional thermal spray methods.","t_start":1.0},{"idea_id":"4ecb134dd6cf55c0","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Cold spray technology has been known for over three decades but has not yet become a viable industrial process.","t_start":1.0},{"idea_id":"61226f1b3cd2f359","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Commercialization of cold spray requires increased efforts and funding from public and private sources.","t_start":1.0},{"idea_id":"38448cfe068f5c32","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Cold spray is one of several named approaches within the broader thermal spray family, including Cold Gas Dynamic Spraying, HVPC, and SPD.","t_start":1.0},{"idea_id":"585a22baefe949f6","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"The cold spray beam has a narrow footprint of approximately 5 mm diameter due to a small nozzle size of 10–15 mm² and a spray distance of 5–25 mm, resulting in a high-density particle beam and precise control over deposition area.","t_start":2.0},{"idea_id":"690296eeab7d0da3","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Cold spray coatings are produced with compressive stresses, similar to micro shot peening, leading to dense and ultra-thick (5–50 mm) coatings without adhesion failure.","t_start":2.0},{"idea_id":"a4fef081d98c6201","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Cold spray coatings formed at low temperature are free of oxides and inclusions and exhibit a wrought-like microstructure.","t_start":2.0},{"idea_id":"0bc309939a6ea0c9","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Cold spray systems can be designed as portable/manual or robotic/fixed configurations.","t_start":2.0},{"idea_id":"07ff738a78c5e7e2","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"The primary gases used in cold spray systems include helium, nitrogen, a mixture of helium and nitrogen, and dry air (79% N₂ - 21% O₂).","t_start":2.0},{"idea_id":"68fa50b205500b82","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"The main components of a cold spray system include a powder feeder, a compressed gas source, a gas heater, a supersonic nozzle (Delaval nozzle), a spraying chamber with motion system, and a parameter monitoring and control system.","t_start":2.0},{"idea_id":"0366477f667beb3a","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Low Pressure Cold Spray (LPCS) uses gas at 5–10 bar pressure, preheated up to 550°C, and employs radial injection of powder downstream of the nozzle throat via Venturi effect.","t_start":3.0},{"idea_id":"8ea16642de36e819","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"In Low Pressure Cold Spray (LPCS), the powder feed is drawn into the nozzle by the Venturi effect when the cross-sectional area ratio (Ai/A*) satisfies Ai/A*≥1.3Po+0.8, where Po is the inlet gas pressure.","t_start":3.0},{"idea_id":"6bc35934e1e79540","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Low Pressure Cold Spray (LPCS) systems offer improved operational safety, portability, flexibility in automation, and reduced spraying cost compared to High Pressure Cold Spray (HPCS), but have deposition efficiency typically below 50%.","t_start":3.0},{"idea_id":"bd33779d87443f91","inferred_predicate":"cito:extends","media_id":"W1511075954","statement":"In Low Pressure Cold Spray (LPCS), powder particles do not pass through the nozzle throat, resulting in wear occurring only in the supersonic portion of the nozzle and extending the nozzle service life.","t_start":3.0},{"idea_id":"659ebbe228b5d6fe","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Cold spray coating involves solid particles impacting a surface with sufficient kinetic energy to induce mechanical and/or metallurgical bonding.","t_start":3.0},{"idea_id":"3c8905ab703d201a","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"High-pressure cold spray systems achieve higher spray efficiency than low-pressure systems, with up to 90% compared to 50%.","t_start":3.0},{"idea_id":"3a8104c1365c7dab","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"In cold spray coating, particle temperature remains below the initial gas preheat temperature due to short dwell time during spray.","t_start":3.0},{"idea_id":"44ff433b034d596e","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"The concept of using particle impact energy for solid-state deposition was first observed in a 1902 patent by Thurston.","t_start":3.0},{"idea_id":"2180dcdf01ec15e3","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"Schoop's 1915 thermal spray process involved molten metal droplets and did not recognize the role of impact energy in solid-state deposition.","t_start":3.0},{"idea_id":"226f8891e0c21d47","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"High Pressure Cold Spray (HPCS) uses gas at 25–30 bar pressure, preheated up to 1000°C, and employs axial injection of powder upstream of the converging section of the nozzle.","t_start":4.0},{"idea_id":"624694a29d20f535","inferred_predicate":"cito:cites","media_id":"W1511075954","statement":"In High Pressure Cold Spray (HPCS), solid particles are accelerated to 600–1200 m/s and impact the substrate upon deposition.","t_start":4.0}],"total_edges":0,"work":"openalex:W1511075954"}