{"anchor":"openalex:W2117338104","by_predicate":{},"contesting_ideas":[],"elapsed_us":469,"energy_joules":0.008442,"supporting_ideas":[{"idea_id":"c55ff65e0b6163c3","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"Weissenberg camera images record only full reflections that pass through the entire Ewald sphere, allowing visual intensity comparison using a scale of increasing intensities.","t_start":1.0},{"idea_id":"5cbd4128aa2db1ff","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"Precession photography provides undistorted views of reciprocal space, simplifying reflection indexing and enabling systematic three-dimensional diffraction data collection.","t_start":1.0},{"idea_id":"9a62c58c1e1edaf6","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"Layer line screens in Weissenberg and precession photography waste crystal life by blocking most reflections without recording them.","t_start":1.0},{"idea_id":"2cd068722871093e","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"Partial reflections at the start or end of oscillation ranges are initially discarded, but this becomes wasteful for large unit cells requiring small oscillation angles.","t_start":1.0},{"idea_id":"4ac57cd86fc624ca","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"Partial reflection intensities can be corrected using calculated partiality factors (p) to estimate full intensity (Iobs/p), requiring precise knowledge of crystal orientation, cell dimensions, and mosaic spread.","t_start":1.0},{"idea_id":"91463b080acf39e7","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"Post refinement is a procedure that scales data using full reflections and then corrects all recorded data for partiality to produce a complete, accurate dataset.","t_start":1.0},{"idea_id":"b68cb6bca1fecbfd","inferred_predicate":"cito:extends","media_id":"W2117338104","statement":"Freezing crystals extends radiation-sensitive crystal lifetime, enabling complete three-dimensional data collection and inclusion of partially recorded reflections.","t_start":1.0},{"idea_id":"e1e50a39019be04d","inferred_predicate":"cito:obtainsDataFrom","media_id":"W2117338104","statement":"Merging data from different crystals averages out differences in absorption characteristics due to varying crystal shapes and vitreous ice environments.","t_start":2.0},{"idea_id":"793d05d65258d87c","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"Serial femtosecond crystallography (SFX) uses ultrafast X-ray pulses to capture diffraction patterns from microcrystals before they are destroyed by radiation damage, resulting in a series of partially observed reflections.","t_start":2.0},{"idea_id":"e60a9810e0a3f8ee","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"The Monte Carlo method for SFX data scaling involves averaging hundreds of observations of the same reflection, each with different degrees of partiality, but is considered inefficient and dependent on chance.","t_start":2.0},{"idea_id":"8fe8eefbd7061c8b","inferred_predicate":"cito:obtainsDataFrom","media_id":"W2117338104","statement":"Synchrotron X-ray data typically provide cleaner diffraction patterns with higher resolution than data from home X-ray sources, enabling better structure determination.","t_start":2.0},{"idea_id":"b7b7714ff2ac848c","inferred_predicate":"cito:cites","media_id":"W2117338104","statement":"The Rmerge values reported in the Gati et al. (2014) study are unusually high and likely result from insufficient data collection, as each reflection was observed only about 12 times, insufficient for reliable scaling.","t_start":2.0}],"total_edges":0,"work":"openalex:W2117338104"}