{"anchor":"openalex:W2909708173","by_predicate":{},"contesting_ideas":[],"elapsed_us":530,"energy_joules":0.00954,"supporting_ideas":[{"idea_id":"42779ca14dd1a038","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Electron cryomicroscopy maps contain both amplitude and phase information, eliminating the phase problem present in X-ray crystallography.","t_start":1.0},{"idea_id":"63b78be0eef92a33","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"High-resolution cryo-EM maps show detailed protein features such as secondary structures and amino acid side chains, but signal strength decreases at the resolution limit.","t_start":1.0},{"idea_id":"10df5addb310885c","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Map visualization can be improved by viewing multiple isosurfaces at different multiples of the standard deviation from the mean to reflect the reliability of features.","t_start":1.0},{"idea_id":"d682750bf178d6eb","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Contrast loss in cryo-EM maps at high resolution can be modeled by a Gaussian fall-off described by a temperature factor or B factor.","t_start":1.0},{"idea_id":"c537a1c1cda5bca8","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Map sharpening enhances high-resolution features relative to low-resolution ones by applying an inverse temperature factor, though it may amplify noise.","t_start":1.0},{"idea_id":"46b169ef00b04577","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Local map sharpening adjusts map amplitudes based on local model-derived amplitudes to improve uniformity across the map at a given contour threshold.","t_start":1.0},{"idea_id":"3d9d367c563f1d1b","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Macromolecules in solution can adopt different conformations, leading to map blurring and non-uniform resolution.","t_start":1.0},{"idea_id":"6135b37b30399cbb","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Confidence maps calculated from electron potential maps using false discovery rate control allow objective assessment of map feature significance compared to background noise.","t_start":2.0},{"idea_id":"75d3bba1622ed347","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"The false discovery rate (FDR) thresholding procedure detects weak structural features in electron density maps that are closer to noise levels than traditional contouring methods.","t_start":2.0},{"idea_id":"3c1d20d579c88024","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Background noise in electron density maps is estimated from regions outside the molecular envelope.","t_start":2.0},{"idea_id":"f04962a5e75cf324","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Confidence maps provide a uniform display of weak density features at a single threshold, reducing the need for multi-sigma level map analysis.","t_start":2.0},{"idea_id":"186d76fe4739f09d","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Confidence maps are computationally efficient, require no prior atomic model, and can be used to interpret electron potential maps in a complementary way.","t_start":2.0},{"idea_id":"ecb26047dbcb1e5c","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Confidence maps are applicable to lower-resolution maps generated by subtomogram averaging.","t_start":2.0},{"idea_id":"cec76ea6b6e13b5f","inferred_predicate":"cito:cites","media_id":"W2909708173","statement":"Objective procedures for evaluating map features, such as confidence maps, will remain relevant in structural biology as imaging techniques advance.","t_start":2.0}],"total_edges":0,"work":"openalex:W2909708173"}