{"anchor":"openalex:W4406156164","by_predicate":{},"contesting_ideas":[],"elapsed_us":763,"energy_joules":0.013734,"supporting_ideas":[{"idea_id":"498ba42da61104e8","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"Pulsatility electrical impedance tomography can detect and monitor acute pulmonary embolism in real time by analyzing pulsatile signals of pulmonary blood flow.","t_start":1.0},{"idea_id":"c29796efb9f83e4c","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"Acute pulmonary embolism induces significant reduction in pulmonary perfusion area and perfusion indicators such as amplitude and SARC.","t_start":1.0},{"idea_id":"79391f8cab40677d","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"Ventilation/perfusion mismatch and dead space percentage show high sensitivity to changes caused by acute pulmonary embolism.","t_start":1.0},{"idea_id":"9b106d23a2e722e8","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"The EIT imaging method based on blood flow pulsation can reflect real-time changes in pulmonary blood flow before and after acute pulmonary embolism.","t_start":2.0},{"idea_id":"3948ccd455d3e700","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"The EIT method shows high consistency with other diagnostic methods in detecting acute pulmonary embolism.","t_start":2.0},{"idea_id":"26f773b77536016e","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"EIT enables non-invasive real-time monitoring of pulmonary perfusion changes in patients with acute pulmonary embolism.","t_start":2.0},{"idea_id":"0a78be28d3daecac","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"The EC-100 pro High-performance EIT system has a maximum acquisition speed of 100 fps and data acquisition accuracy better than 0.01‰ within the frequency range of 10 kHz to 250 kHz.","t_start":3.0},{"idea_id":"e4fc710f08856eaa","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"EIT data were acquired using an opposing excitation and adjacent measurement mode with 16 electrodes, a frame rate of 40 fps, an excitation current amplitude of 1.25 mA, and a frequency of 50 kHz.","t_start":3.0},{"idea_id":"35fc1de598d9e208","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"Animals were anesthetized with a combination of propofol, zoletil® 50, and xylazine, followed by maintenance with isoflurane gas at a respiratory rate of 14 breaths per minute, tidal volume of 250 ml, and ventilation rate of 3.5 L min⁻¹.","t_start":3.0},{"idea_id":"3bd2b71625eb2a00","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"A central venous catheter and a Swan-Ganz catheter were inserted into the left external jugular vein and pulmonary artery, respectively, to monitor pressure waveforms and ensure the balloon remained contracted.","t_start":3.0},{"idea_id":"fa85b2a0f3599ff0","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"The EIT electrode tape with 16 electrodes was positioned between the third and fourth ribs of the pig in an equally spaced manner and secured with self-adhesive bandages.","t_start":3.0},{"idea_id":"70d47836054127bc","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"The study assumes no differences in lung electrode positioning, metabolic ability of 10% NaCl, or degree of pulmonary embolism across all experimental animals.","t_start":3.0},{"idea_id":"855835b8de83c648","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"In the first stage, EIT data were collected for 30 minutes in the normal state (pre-embolism), followed by a brief end-expiratory pause and injection of 5 ml of 10% NaCl solution to observe impedance changes for 10 to 15 seconds.","t_start":3.0},{"idea_id":"fc14437bf67678d9","inferred_predicate":"cito:cites","media_id":"W4406156164","statement":"In the second stage, EIT data were collected for 30 minutes in the state of acute pulmonary embolism (post-embolism), achieved by inflating the aerostat gasbag until the pulmonary artery pressure waveform became undetectable.","t_start":3.0}],"total_edges":0,"work":"openalex:W4406156164"}