{"anchor":"openie:work:free-microfluidics-fab-cad-instruments","by_predicate":{},"contesting_ideas":[],"elapsed_us":11954,"energy_joules":0.21517199999999997,"supporting_ideas":[{"idea_id":"588593b694ac9e37","inferred_predicate":"cito:cites","media_id":"mf_cad:3d-printed-reservoir-manifold","statement":"3D-printed reservoir manifold for academic chip mounting: Manifold body 50 mm × 50 mm × 20 mm with integrated reservoir wells (5 mL each), Luer-lock chip docking interface, and pneumatic input ports. Three reservoir wells for typical droplet-microfluidics applications (cells / beads / oil). Compatible with standard 1/16 inch PEEK tubing and disposable syringe interfaces.","t_start":1.0},{"idea_id":"7ede76f04ffe53fa","inferred_predicate":"cito:cites","media_id":"mf_cad:96-well-plate-format-chip-outline","statement":"96-well-plate-format chip outline (SBS / ANSI standard): ANSI/SLAS 1-2004 96-well plate footprint (127.76 × 85.48 mm) with optional integration of 96 wells at 9 mm pitch starting at A1=14.38, 11.24 mm; chip body machined to match plate dimensions for handling by liquid-handling robots","t_start":1.0},{"idea_id":"0ce4f742ee843174","inferred_predicate":"cito:cites","media_id":"mf_cad:agricultural-microbiome-cartridge","statement":"Agricultural microbiome sample-to-sequencing cartridge: Sample input (5 mL soil + buffer slurry) → bead-beating lysis chamber (2 mL with embedded beads) → silica column extraction (200 µL) → PCR amplification chamber (50 µL with embedded heater) → library prep chamber → output to MinION flow cell. Cartridge total dimensions 100 mm × 60 mm × 15 mm.","t_start":1.0},{"idea_id":"5658e3695ba479b8","inferred_predicate":"cito:cites","media_id":"mf_cad:akin-2018-single-cell-seq-chip-cad","statement":"Akin 2018 single-cell sequencing chip CAD: Drop-seq style: flow-focusing 75 µm orifice with 50 µm channels for cell encapsulation; bead inlet, oil inlet, cell inlet, collection serpentine 200 mm.","t_start":1.0},{"idea_id":"110021fd38062aee","inferred_predicate":"cito:cites","media_id":"mf_cad:aline-laminate-flow-cell-pointer","statement":"ALine laminate flow cell template pointer: Laminate flow cell catalog: typically 1-3 mm wide, 0.2-0.5 mm tall channels in PSA tape sandwich between rigid layers.","t_start":1.0},{"idea_id":"dec645f6acadc25b","inferred_predicate":"cito:cites","media_id":"mf_cad:anna-2003-flow-focusing-supplementary-cad","statement":"Anna 2003 flow-focusing droplet supplementary mask layout: Flow-focusing junction with 43.5 µm orifice, 197 µm wide outer channels, central inner channel 197 µm; depth 117 µm per Anna 2003 Fig. 1.","t_start":1.0},{"idea_id":"65d44ddaad82a7a9","inferred_predicate":"cito:cites","media_id":"mf_cad:bbb-on-chip-teer-reference","statement":"Blood-brain barrier-on-chip with TEER electrodes (Booth 2012 architecture): Two parallel 0.5 mm × 200 µm channels separated by polycarbonate track-etched membrane (0.4 µm pore). Top channel: blood/luminal side (brain endothelial cells). Bottom channel: brain/abluminal side (astrocytes). 4 TEER electrodes (2 per channel) at 5 mm spacing for impedance measurement.","t_start":1.0},{"idea_id":"8db51c140fd89dde","inferred_predicate":"cito:cites","media_id":"mf_cad:beaucage-3d-printed-microfluidic-library","statement":"Beaucage 3D-printed microfluidic library: Library of canonical features: T-junctions, flow-focusing, mixers, droplet collectors at 200-1000 µm channel widths; standardized 1/4-28 thread inlet ports.","t_start":1.0},{"idea_id":"9832f505fe2dbc98","inferred_predicate":"cito:cites","media_id":"mf_cad:beebe-2000-stop-flow-valve-cad","statement":"Beebe 2000 stimuli-responsive hydrogel valve geometry: Channel 1 mm wide × 200 µm deep; in-channel hydrogel valve posts 100 µm dia at pH-controlled junction.","t_start":1.0},{"idea_id":"799b078334baa243","inferred_predicate":"cito:cites","media_id":"mf_cad:bento-lab-capillary-tray","statement":"Bento Lab capillary electrophoresis tray: 8-well comb, 1 mm well spacing, 70 mm separation length, 5 mm gel depth; UV imaging window 70 × 50 mm.","t_start":1.0},{"idea_id":"de68bef5afced2ed","inferred_predicate":"cito:cites","media_id":"mf_cad:bento-lab-mk2-pcb-cartridge","statement":"Bento Lab Mk2 PCB schematic + cartridge geometry: 0.2 mL standard PCR tube tray (8 × wells), 1.5 mL microfuge tube rotor (6 × slots), and capillary gel-electrophoresis tray with embedded UV LED window.","t_start":1.0},{"idea_id":"1ce82586b02d8978","inferred_predicate":"cito:cites","media_id":"mf_cad:bhattacharjee-2016-3d-printed-microfluidic-toolkit","statement":"Bhattacharjee 2016 3D-printed microfluidic toolkit (Folch lab): Toolkit of modular components: T-junctions, mixers, valves, pumps; channel widths 200-500 µm, 200 µm depth, modular Lego-like ports.","t_start":1.0},{"idea_id":"9085c108fafa509e","inferred_predicate":"cito:cites","media_id":"mf_cad:black-hole-lab-foundry-chip-designs","statement":"Black Hole Lab Foundry chip designs (open since 2018): Range includes droplet generators (T, FF), mixers (HBM), and gradient generators; channel widths 50-200 µm.","t_start":1.0},{"idea_id":"163f2648590a533c","inferred_predicate":"cito:cites","media_id":"mf_cad:bluetooth-poc-cartridge-reference","statement":"Bluetooth POC cartridge reference (Cue/Lucira-class): Sample-application port (200 µL) → mixing chamber with lyophilized reagents → metering chamber → detection chamber (50 µL) with embedded electrodes (electrochemical) or excitation/emission window (fluorescent). Cartridge dimensions 80 mm × 30 mm × 8 mm, designed to mate with open-bluetooth-wearable-poc-reader instrument.","t_start":1.0},{"idea_id":"799e03cc648eeab0","inferred_predicate":"cito:cites","media_id":"mf_cad:bongopump-chip-mount-cad","statement":"BongoPump chip mount CAD: Chip clamp 90 × 30 mm accepts standard 75 × 25 mm slide; integrated luer-to-1/16\" adapters at 4 corners.","t_start":1.0},{"idea_id":"7f9f574abc613f85","inferred_predicate":"cito:cites","media_id":"mf_cad:booth-kim-2012-bbb-on-chip-cad","statement":"Booth/Kim 2012 BBB-on-chip geometry: Two-channel co-culture: top channel (lumen, endothelial) 2 × 0.2 mm × 0.2 mm deep; bottom channel (abluminal, astrocyte) 2 × 0.2 mm × 0.2 mm deep; PC membrane (0.4 µm pore) sandwich.","t_start":1.0},{"idea_id":"03cbbfaa6a9555ca","inferred_predicate":"cito:cites","media_id":"mf_cad:centrifugal-disc-reference-cd","statement":"Centrifugal lab-on-disc reference (CD-format): 120 mm diameter PMMA disc with 4 parallel assay paths radiating from central sample-application well at 5 mm radius. Each path: sample chamber → metering chamber → reagent chamber 1 (burst at 12 Hz) → mixing chamber → reagent chamber 2 (burst at 20 Hz) → detection cell at 35 mm radius. Channel widths 200–500 µm, depths 100–300 µm.","t_start":1.0},{"idea_id":"e9d5cc1d600c9ff7","inferred_predicate":"cito:cites","media_id":"mf_cad:coulter-counter-constriction-chip","statement":"Coulter counter constriction chip (impedance cell counting): Funnel-shaped flow channel narrowing to 30 µm × 30 µm × 100 µm constriction with two flanking platinum electrodes spanning the constriction; entrance channel widens to 200 µm; exit channel widens to 500 µm for downstream collection. Cells passing through constriction modulate impedance between electrodes.","t_start":1.0},{"idea_id":"766121da8ec2e1df","inferred_predicate":"cito:cites","media_id":"mf_cad:dielectrophoresis-cell-sorter-chip","statement":"Dielectrophoresis cell sorter chip (Pohl-DEP architecture): 200 µm × 50 µm flow channel with 5 pairs of opposing-electrode arrays (each 50 µm × 200 µm) along channel length. Cell suspension flows through, with AC field at multiple frequencies applied to electrode pairs to selectively trap or deflect cells based on dielectric properties. Side outlet for trapped cell collection.","t_start":1.0},{"idea_id":"b979a91d68c49a4d","inferred_predicate":"cito:cites","media_id":"mf_cad:dld-deterministic-lateral-displacement-array","statement":"DLD (deterministic lateral displacement) reference array, 5 µm cutoff: Hexagonal post array with 10 µm post diameter, 6 µm gap, 1/10 row shift fraction over 50 mm length; cutoff diameter ~5 µm; 8-row design giving 4× lateral displacement of large particles","t_start":1.0},{"idea_id":"b0119e12b3c3597f","inferred_predicate":"cito:cites","media_id":"mf_cad:dolomite-mitos-chip-cad-partial","statement":"Dolomite Mitos chip range CAD (partial-open): Mitos chip footprint 22.5 × 22.5 × 4 mm; 100 µm × 100 µm channels; standard 4-port FluidicConnect interface.","t_start":1.0},{"idea_id":"c077d5f8f8df5488","inferred_predicate":"cito:cites","media_id":"mf_cad:drop-seq-co-encapsulation-chip","statement":"Drop-seq co-encapsulation chip (Macosko 2015 architecture): Three input channels: cell suspension (50 µm × 100 µm), bead suspension (50 µm × 100 µm), oil with surfactant (3 × 100 µm × 100 µm). Channels co-flow into 100 µm × 100 µm flow-focusing junction with 75 µm orifice for monodisperse droplet generation. Downstream serpentine collection channel.","t_start":1.0},{"idea_id":"2acea6b0ab7753a7","inferred_predicate":"cito:cites","media_id":"mf_cad:droplet-picoinjector-side-channel","statement":"Droplet picoinjector with side-channel reagent delivery: 50 µm × 25 µm pre-formed droplet channel intersected by 10 µm × 25 µm reagent injection orifice with electrocoalescence electrodes; downstream serpentine for mixing","t_start":1.0},{"idea_id":"da88534e0594a24e","inferred_predicate":"cito:cites","media_id":"mf_cad:effenhauser-1993-ce-chip-mask","statement":"Effenhauser 1993 CE chip mask: Double-T injector with 30 µm wide × 10 µm deep separation channel, 80 mm separation length, 4 reservoirs.","t_start":1.0},{"idea_id":"5d7106e857663b6e","inferred_predicate":"cito:cites","media_id":"mf_cad:esi-emitter-glass-chip","statement":"Glass chip with integrated ESI emitter (Ramsey reference): Separation channel 60 mm × 50 µm × 10 µm with cross-injector at upstream end; downstream emitter outlet fed into pulled-glass ESI tip (5 µm OD) bonded in alignment slot","t_start":1.0},{"idea_id":"9027c17e2bd8189a","inferred_predicate":"cito:cites","media_id":"mf_cad:ewod-electrode-array-reference-80","statement":"EWOD electrode array reference (80-electrode, 1.5 mm pitch): 80 individually addressable square electrodes at 1.5 mm × 1.5 mm pitch arranged in 8 × 10 array; reservoir electrodes (3 mm × 3 mm) at four corners; gap between electrodes 50 µm; total active area 12 mm × 15 mm. Top plate is unpatterned ITO common ground.","t_start":1.0},{"idea_id":"5a38947f8ed29aa4","inferred_predicate":"cito:cites","media_id":"mf_cad:exosome-separation-dld-chip","statement":"Exosome separation DLD chip (sub-200 nm cutoff): Hexagonal post array with 500 nm post diameter, 100 nm gap, 1/20 row shift fraction over 20 mm length. Cutoff diameter ~80 nm (within exosome size range, 30–150 nm). Sample inlet, buffer-sheath inlet, and four size-fractionated outlets for size-based exosome enrichment from biological fluids.","t_start":1.0},{"idea_id":"6bb26d940b0aea6d","inferred_predicate":"cito:cites","media_id":"mf_cad:fluidic-not-gate-bubble-logic","statement":"Fluidic NOT gate (bubble-logic primitive): T-junction with asymmetric channel widths (100 µm and 50 µm branches) following Prakash 2007 design: bubble-bias through narrow branch implements logical inversion. Typical implementations include AND/OR/NOT/SR-latch primitives in cascade.","t_start":1.0},{"idea_id":"4dd3f2103e74eb68","inferred_predicate":"cito:cites","media_id":"mf_cad:fluigent-chip-designs-partial-open","statement":"Fluigent open chip designs (partial): Standard Fluigent footprint 24 × 60 mm with 8-port interface compatible with Fluiwell holder.","t_start":1.0},{"idea_id":"7ff1cb6791b895d7","inferred_predicate":"cito:cites","media_id":"mf_cad:glass-capillary-electrophoresis-cross-injector","statement":"Glass CE chip with cross-injector (Harrison reference): cross-injector geometry with 60 mm separation channel and 5 mm short-arm injection cross; 4 reservoir wells","t_start":1.0},{"idea_id":"7c693b7d7345bbc0","inferred_predicate":"cito:cites","media_id":"mf_cad:gut-on-chip-dual-channel-reference","statement":"Gut-on-chip dual-channel reference (Kim 2012 architecture): Two parallel 1 mm × 150 µm channels separated by porous PDMS membrane. Top channel: gut epithelial side (Caco-2 + microbiome). Bottom channel: vascular side. Side vacuum channels apply 10% cyclic strain at 0.15 Hz to mimic intestinal peristalsis.","t_start":1.0},{"idea_id":"d04db06008b59a39","inferred_predicate":"cito:cites","media_id":"mf_cad:herringbone-mixer-reference-mrna-lnp","statement":"Staggered herringbone mixer chip for mRNA-LNP synthesis: Y-junction inlet for two streams (aqueous + ethanol/lipid) at 200 µm × 75 µm cross-section, merging into 200 µm × 100 µm main flow channel with 25 µm-deep staggered herringbone grooves at 45°. Mixer length 30 mm with 6-cycle alternating herringbone groups. Single outlet for collected LNP product.","t_start":1.0},{"idea_id":"6e9f82cc1bcf2662","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-concordia-montreal-2019-chip","statement":"iGEM Concordia-Montreal 2019 microfluidic chip CAD: Flow-focusing droplet generator with 25 µm orifice, 50 µm × 50 µm channels; serpentine collection 200 mm long.","t_start":1.0},{"idea_id":"096abae42ff30289","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-duesseldorf-2018-chip","statement":"iGEM Düsseldorf 2018 microfluidic chip CAD: Plant-cell assay chamber 4 × 4 × 0.1 mm with 8 perfusion micro-inlets (50 µm each).","t_start":1.0},{"idea_id":"20a1f0db9f1a259e","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-epfl-2019-crispr-cartridge","statement":"iGEM EPFL 2019 CRISPR cartridge CAD: Sample inlet 5 mm dia, 4 reagent reservoirs (50 µL each), serpentine reaction channel 1 mm × 0.2 mm × 80 mm long, lateral flow detection window 5 × 25 mm.","t_start":1.0},{"idea_id":"f3b366808bc533ae","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-eth-zurich-2018-microfluidic-chip","statement":"iGEM ETH Zurich 2018 microfluidic chip CAD: Multi-channel sample-mixing chip with 6 parallel reaction chambers (1 × 1 × 0.1 mm each), shared inlet and waste manifolds.","t_start":1.0},{"idea_id":"dfa040bb1011a944","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-heidelberg-2017-synbio-chip","statement":"iGEM Heidelberg 2017 synthetic biology chip CAD: Parallel reaction chambers (8 chambers, 2 × 2 × 0.05 mm) with shared inlet manifold and pneumatic Quake valves; 100 µm flow channels.","t_start":1.0},{"idea_id":"a0c9de1e36dc2354","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-hkust-2020-crispr-cas13-chip","statement":"iGEM HKUST 2020 CRISPR-Cas13 chip CAD: Single-pot reaction chamber 50 µL, fed via 1 mm channels from sample inlet; fluorescence readout window.","t_start":1.0},{"idea_id":"d807f671be599ac2","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-imperial-2014-aqua-bot-chip","statement":"iGEM Imperial College 2014 Aqua_Bot chip CAD: Single-channel sample chamber 5 × 5 × 0.05 mm with biosensor membrane region 2 × 2 mm; serpentine waste channel.","t_start":1.0},{"idea_id":"d819b4ce662d63d8","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-manchester-2018-chip","statement":"iGEM Manchester 2018 microfluidic chip CAD: Single-cell isolation chip with array of hydrodynamic traps (10 µm trap, 25 µm bypass) on 100 µm × 50 µm main channel; 100 traps total.","t_start":1.0},{"idea_id":"c080d7f24c95e6ac","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-marburg-2019-chip","statement":"iGEM Marburg 2019 microfluidic chip CAD: Vibrio natriegens cultivation chip with single 5 × 5 × 0.025 mm chamber and 50 µm feed/waste channels.","t_start":1.0},{"idea_id":"ea3e9caef6507463","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-sorbonne-2018-chip","statement":"iGEM Sorbonne 2018 microfluidic chip CAD: Two-layer co-culture chip: top channel 1 × 1 × 0.05 mm, bottom channel 1 × 1 × 0.05 mm, separated by 10 µm-pore PET membrane (5 × 5 mm window).","t_start":1.0},{"idea_id":"a4b8dbc02e482caf","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-stockholm-2020-chip","statement":"iGEM Stockholm 2020 microfluidic chip CAD: Diagnostic chip for COVID-19-related biomarker readout, 6 parallel detection chambers (3 mm dia × 0.5 mm deep), shared sample inlet, 0.5 mm channels.","t_start":1.0},{"idea_id":"27432b4e3e4b1131","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-toronto-2019-petase-chip","statement":"iGEM Toronto 2019 PETase chip CAD: Reactor channel 2 mm × 0.1 mm × 50 mm with integrated packed-bed region 10 mm; inlet/outlet 1.5 mm Luer ports.","t_start":1.0},{"idea_id":"b438998c5af449c7","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-tsinghua-2017-chip","statement":"iGEM Tsinghua 2017 microfluidic chip CAD: Heavy-metal water assay chip: serpentine pre-mixer 0.5 × 0.5 × 50 mm into 4 parallel detection wells (4 mm dia × 0.5 mm deep).","t_start":1.0},{"idea_id":"0db57a8024750cbc","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-tu-delft-2014-paper-microfluidic-chip","statement":"iGEM TU Delft 2014 paper microfluidic chip CAD: 8 detection zones radially around central sample inlet, each 5 mm diameter; channel widths 1 mm; total chip 40 mm diameter.","t_start":1.0},{"idea_id":"319cbb38d0a682b6","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-tu-delft-2018-chip","statement":"iGEM TU Delft 2018 microfluidic chip CAD: Continuous-culture chemostat with 4 parallel growth chambers (1 × 1 × 0.05 mm) and integrated mixer; 100 µm feed channels.","t_start":1.0},{"idea_id":"235e77a2e7f28fae","inferred_predicate":"cito:cites","media_id":"mf_cad:igem-wageningen-ur-2019-paper-detection-chip","statement":"iGEM Wageningen-UR 2019 paper detection chip CAD: 4 detection zones, each 4 mm diameter, fed from central sample inlet via 1 mm channels; chip 30 × 30 mm.","t_start":1.0},{"idea_id":"94c9a5dd75e97e6f","inferred_predicate":"cito:cites","media_id":"mf_cad:ihc-slide-flow-chamber","statement":"IHC / pathology slide flow chamber reference: 25 mm × 75 mm × 200 µm flow chamber sized to a standard pathology slide footprint (3 inch × 1 inch). Reagent inlet port + 4 reagent wells along chamber periphery for sequential reagent introduction. Shared waste outlet at chamber exit.","t_start":1.0},{"idea_id":"225de84451280406","inferred_predicate":"cito:cites","media_id":"mf_cad:inertial-spiral-cell-focuser","statement":"Inertial spiral cell focuser reference: Archimedean spiral with 8 turns, 100 µm × 100 µm channel cross-section, inner radius 5 mm, outer radius 25 mm; sample inlet plus single sheath inlet; 4-bifurcation outlet for size-based collection","t_start":1.0}],"total_edges":0,"work":"openie:work:free-microfluidics-fab-cad-instruments"}