{
  "grounded_evidence_statements": [
    "Microfluidic Failure-Mode Guardrail (EWOD digital microfluidics cartridge fabrication): Failure [Dielectric breakdown]: shorts between droplet and electrode; droplet electrolyzes -> fix: thicker dielectric; lower operating voltage; verify defect-free deposition; Failure [Droplet pinning]: droplet does not move on electrode activation -> fix: verify hydrophobic coating intact; increase voltage; add surfactant trace to droplet; Failure [Bio-fouling]: droplet performance degrade (https://github.com/openIE-dev/free-microfluidics-project/blob/main/fab/recipes.jsonl#page=2)",
    "Inside Therapeutics LNP Microfluidic Cartridge (Inside Therapeutics SAS): Inside Therapeutics LNP Microfluidic Cartridge [Subsystems: lnp-microfluidic-mixer, fabrication-thermoplastic-injection-molding, disposable-cartridge-architecture; CPC: B01F 33/3017, A61K 9/127] (https://github.com/openIE-dev/free-microfluidics-project#page=1)",
    "SHUGA POC molecular diagnostic cartridge (2024 demonstration) (Various — Sabeti / Zhang Broad lineage): SHUGA POC molecular diagnostic cartridge (2024 demonstration) [Subsystems: architecture-stat-test-cartridge, thermal-isothermal-amplification, fabrication-thermoplastic-injection-molding; CPC: B01L 3/00, C12Q 1/68] (https://github.com/openIE-dev/free-microfluidics-project#page=1)",
    "Machine-learning-driven droplet generator design (Lashkaripour 2021/2024) (Densmore lab, Boston University, 2021): Disclosed DAFD (Design Automation of Fluid Dynamics): ML model trained on microfluidic experimental data predicts flow-focusing droplet generator geometry from desired droplet size and rate. Anticipates: ML-as-design-automation for microfluidic chip geometry, and the broader trend of replacing CFD simulation with trained models for microfluidic design. (https://github.com/openIE-dev/free-microfluidics-project#page=1)",
    "The future of microfluidic point-of-care diagnostic devices (Ren & Lee) (Ren, Wu (Hong Kong UST)): The future of microfluidic point-of-care diagnostic devices (Ren & Lee) (https://github.com/openIE-dev/free-microfluidics-project#page=1)"
  ],
  "negative_space_guardrails": [
    "[https://github.com/openIE-dev/free-microfluidics-project/blob/main/fab/recipes.jsonl#page=2] Microfluidic Failure-Mode Guardrail (EWOD digital microfluidics cartridge fabrication): Failure [Dielectric breakdown]: shorts between droplet and electrode; droplet electrolyzes -> fix: thicker dielectric; lower operating voltage; verify defect-free deposition; Failure [Droplet pinning]: droplet does not move on electrode activation -> fix: verify hydrophobic coating intact; increase voltage; add surfactant trace to droplet; Failure [Bio-fouling]: droplet performance degrade",
    "[https://github.com/openIE-dev/free-microfluidics-project#page=1] Boom guanidinium-silica nucleic acid extraction (Boom et al., University of Amsterdam, 1990): Disclosed guanidinium-silica nucleic acid extraction chemistry that, while not microfluidic on its own, became the dominant on-cartridge sample-prep chemistry across virtually every commercial molecular diagnostic cartridge (BioFire, Cepheid, Abbott, Roche, GenMark). Included in the corpus because cartridge architectural disclosures cannot be evaluated without recognizing this as the",
    "[https://github.com/openIE-dev/free-microfluidics-project#page=1] Plateau-Rayleigh instability (combined droplet-formation theory) (Joseph Plateau (1873); Lord Rayleigh (1879), 1879): Combined entry for the Plateau-Rayleigh instability, the foundational classical theory underlying every microfluidic droplet generator (T-junction, flow-focusing, co-flow, step-emulsification). Plateau 1873 (experimental anchor on existence of the instability) plus Rayleigh 1879 (analytical derivation of the most-unstable wavelength) together publish 'a liquid"
  ],
  "report": {
    "matched_count": 2,
    "matched_standards": [
      {
        "binding_posture": "MANDATORY_STATUTORY",
        "body_or_jurisdiction": "US FDA / ISO TC 210",
        "canonical_url": "https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-820",
        "domain": "biomedical",
        "match_score": 12.5,
        "quantitative_invariants": "Traceable Design Input -> Output -> Verification/Validation matrix; risk management per ISO 14971; analytical LoD/LoQ validation.",
        "standard_id": "FDA-21-CFR-820 / ISO-13485:2016",
        "title": "Medical Devices Quality Management System Regulation (QMSR) & Design Controls",
        "verification_checklist": [
          "Maintain immutable Design History File (DHF) with BLAKE3 artifact fixity",
          "Verify analytical sensitivity/specificity and biocompatibility (ISO 10993)",
          "Document software/firmware lifecycle per IEC 62304"
        ]
      },
      {
        "binding_posture": "CONFORMITY_STANDARD",
        "body_or_jurisdiction": "W3C WAI / ISO",
        "canonical_url": "https://www.w3.org/TR/WCAG22/",
        "domain": "accessibility",
        "match_score": 2.5,
        "quantitative_invariants": "Contrast >= 4.5:1; 100% labeled interactive controls; >= 24x24 CSS px target size; keyboard/screen-reader & AAC symbol parity.",
        "standard_id": "W3C-WCAG-2.2-AA / ISO-14289 (PDF/UA)",
        "title": "Web Content Accessibility Guidelines 2.2 Level AA & Cognitive Easy-Read / AAC Inclusion",
        "verification_checklist": [
          "Ensure zero unlabeled buttons/inputs across light DOM and Shadow DOM components",
          "Respect prefers-reduced-motion and provide non-audio captions/transcripts",
          "Offer plain-language Easy-Read (<= 15 words/sentence) + AAC concept projection"
        ]
      }
    ],
    "query": "microfluidic droplet diagnostic blood cartridge",
    "readiness_tier": "REGULATORY_GATE_TRIGGERED",
    "schema": "scholar.policy_standards.v1",
    "statutory_triggers": [
      "FDA-21-CFR-820 / ISO-13485:2016 (US FDA / ISO TC 210)"
    ],
    "total_catalogued_frameworks": 14
  }
}