algo-spo2-estimation

12 moment(s) that assert this concept — showing 1–12 of 12

strong12 independent sources
↣ how this spread over time →

reuse terms across this evidence: 12 openly licensed

provenance — click a node to open its encoding unit
[1] John[2] Takuo[3] Sokwoo[4] Bragi[5] EA[6] Michele[7] ISO/IEC[8] Masimo[9] Yitzhak[10] Salar[11] John[12] Withings
showing 12 of 12 moments
scholarly papers (1)
John Allen (Freeman Hospital / Newcastle) · free_wearable_corpus · en
1[Free Wearable Corpus CC0-1.0 Prior Art · Allen (2007) — 'Photoplethysmography and its application in clinical physiological measurement' (2007-02-20, John Allen (Freeman Hospital / Newcastle), academic, other, IP: public-domain)] Canonical review collecting the state of PPG measurement and the physiological parameters derivable from a PPG signal as of 2007 — heart rate, HRV, respiratory rate, SpO2, blood-pressure surrogates, arterial-stiffness/aging indices, vasomotor assessment. Relevant to wearable claims that recite 'deriving [parameter X] from a photoplethysmography signal' for any X covered here: the derivation was a published, enabled technique by 2007, defeating novelty of the bare derivation and supplying § 103 motivation for the form-factor+PPG+algorithm combinations. The single most-cited anchor for PPG-derived-metric wearable patents. Disclosed wearable sensors & endpoints: sensor-ppg, algo-hr, algo-hrv, algo-respiratory-rate, algo-spo2-estimation, algo-pwv-bp-estimation, heart-rate, respiratory-rate, blood-oxygen, blood-pressure. CPC: A61B 5/02416, A61B 5/024, A61B 5/1455, A61B 5/021.
“Allen J. 'Photoplethysmography and its application in clinical physiological measurement.' Physiological Measurement 2007;28(3):R1-R39. doi:10.1088/0967-3334/28/3/R01. — Canonical review collecting the state of PPG measurement and the physiological parameters derivable from a PPG signal as of 2007 — heart rate, HRV, respiratory rate, SpO2, blood-pressure surrogates, arterial-s…”
written · p. 136 · 2007-02-20 · open
Takuo Aoyagi (Nihon Kohden) · free_wearable_corpus · en
2[Free Wearable Corpus CC0-1.0 Prior Art · Aoyagi (1974) — two-wavelength pulse oximetry principle (1974, Takuo Aoyagi (Nihon Kohden), private, other, IP: patented)] Discloses the pulsatile two-wavelength ratiometric method that underlies every non-invasive SpO2 device: comparing the AC/DC ratios of light absorbance at (typically) red ~660 nm and infrared ~940 nm through pulsatile tissue to compute arterial oxygen saturation. Any wearable claim reciting 'a first and second light source at distinct wavelengths and a photodetector configured to compute oxygen saturation from a ratio of pulsatile components' reads on this. § 102 prior art for the SpO2 principle from 1974; the wrist/ring/earbud form-factor variants are obvious combinations under [[obviousness-template]]. Disclosed wearable sensors & endpoints: sensor-spo2, sensor-ppg, sensor-multi-wavelength-ppg, algo-spo2-estimation, blood-oxygen, earlobe, finger. CPC: A61B 5/14551, A61B 5/1455, A61B 5/02416.
“Aoyagi T, et al. — the pulsatile two-wavelength (red/infrared) ratio method for non-invasive arterial oxygen saturation, presented at the 13th Annual Meeting of the Japan Society of Medical Electronics and Biological Engineering (1974); commercialized as the Nihon Kohden 'Ear Oximeter OLV-5100' (1975) and Minolta 'Oximet MET-1471' (1977). History documented in Severinghaus JW,…”
written · p. 137 · 1974-01-01 · open
Sokwoo Rhee / Boo-Ho Yang / Haruhiko Harry Asada (MIT d'Arbeloff Lab) · free_wearable_corpus · en
3[Free Wearable Corpus CC0-1.0 Prior Art · MIT wearable ring sensor (Rhee, Yang, Asada) — finger-ring PPG for ambulatory monitoring (2001-07, Sokwoo Rhee / Boo-Ho Yang / Haruhiko Harry Asada (MIT d'Arbeloff Lab), academic, ring, IP: patented)] Discloses a finger-ring-form-factor wearable PPG sensor with motion-artifact-resistant optical/mechanical design, low-power operation, on-body processing, and wireless telemetry of heart rate and SpO2 for ambulatory monitoring — i.e. the smart-ring physiological monitor, ~14 years before the commercial smart-ring wave. Directly anticipates ring-form claims combining 'a ring body', 'a PPG emitter/detector at the inner ring surface', 'motion-artifact compensation', and 'wireless transmission of derived vitals'. Anchor for the ring × PPG cross-cut; [[oura-ring-gen1-2015]] and similar products descend from it. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-accelerometer, algo-hr, algo-spo2-estimation, heart-rate, blood-oxygen, blood-volume-pulse, finger. CPC: A61B 5/02427, A61B 5/681, A61B 5/02416, A61B 5/6826.
“Rhee S, Yang B-H, Asada HH. 'Artifact-resistant power-efficient design of finger-ring plethysmographic sensors.' IEEE Transactions on Biomedical Engineering 2001;48(7):795-805 (and Asada HH, Shaltis P, Reisner A, Rhee S, Hutchinson RC. 'Mobile monitoring with wearable photoplethysmographic biosensors.' IEEE Engineering in Medicine and Biology Magazine 2003;22(3):28-40). — Disc…”
written · p. 138 · 2001-07-01 · open
Bragi GmbH · free_wearable_corpus · en
4[Free Wearable Corpus CC0-1.0 Prior Art · Bragi Dash (2014) — the first true 'hearable': in-ear PPG heart rate, accelerometer, storage and touch control inside wireless earbuds (2014-02-25, Bragi GmbH, private, earbud, IP: patented)] Discloses fully-wireless in-ear earbuds with a reflectance-PPG heart-rate and SpO2 sensor against the ear-canal wall, an accelerometer for head-gesture and step/activity tracking, onboard music storage, a bone-conduction microphone, and capacitive touch control — i.e. physiological sensing integrated into wireless earbuds. Anticipates hearable claims combining 'a wireless earbud housing', 'an in-ear PPG/SpO2 sensor', 'an accelerometer for activity or head gesture', and 'on-device media and controls' from 2014. Product-side anchor for the earbud × PPG cross-cut. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-spo2, sensor-accelerometer, sensor-microphone-bone, algo-hr, algo-spo2-estimation, algo-step-count, algo-activity-classification, heart-rate, blood-oxygen. CPC: A61B 5/02416, H04R 1/10, A61B 5/1118, A61B 5/14552.
“Bragi GmbH. 'The Dash' wireless smart earphones, crowdfunded February 2014 (shipped 2016) — fully wireless in-ear earbuds with a reflectance-PPG heart-rate sensor and oxygen-saturation estimation against the ear-canal wall, a 3-axis accelerometer (head-gesture and step/activity tracking), 4 GB onboard music storage, bone-conduction microphone, and capacitive touch control. — D…”
written · p. 191 · 2014-02-25 · open
EA Redwood Shores (Visceral Games) / Electronic Arts · free_wearable_corpus · en
5[Free Wearable Corpus CC0-1.0 Prior Art · Dead Space — 'RIG' (suit with body-mounted health display and projected holographic UI) (2008-10-13, EA Redwood Shores (Visceral Games) / Electronic Arts, fictional, garment, IP: fictional)] Discloses a worn suit with (a) a body-mounted (spinal) physiological-status display readable by third parties, (b) oxygen-level monitoring, and (c) a holographic interface projected in the wearer's view. Relevant to wearable-with-externally-visible-status-display claims combining 'a body-worn garment', 'a sensor measuring a physiological parameter (e.g. SpO2 or general health state)', and 'a display on the garment surface presenting that parameter to onlookers', and to body-projected holographic-UI claims. § 103 motivation as of 2008. Cf. [[logans-run-lifeclock]] (body-worn color status display), [[mass-effect-omni-tool]] (projected UI). Disclosed wearable sensors & endpoints: algo-spo2-estimation, health-status, blood-oxygen, spine, back, whole-body. CPC: A41D 1/00, A61B 5/1455, G09F 9/00, G06F 3/01.
“Dead Space (EA Redwood Shores / Electronic Arts, released 13 October 2008); the 'Resource Integration Gear' suit with a segmented LED strip on the wearer's back/spine displaying current health (visible to others), oxygen monitoring, a holographic inventory/menu projected in front of the wearer, and a 'stasis' module. — Discloses a worn suit with (a) a body-mounted (spinal) phy…”
written · p. 132 · 2008-10-13 · open
Michele Magno et al. (ETH Zürich and collaborators) · free_wearable_corpus · en
6[Free Wearable Corpus CC0-1.0 Prior Art · H-Watch (Magno et al., 2024) — open-source ARM Cortex-M4F + ML + NB-IoT + energy-harvesting research smartwatch (2024, Michele Magno et al. (ETH Zürich and collaborators), academic, watch, IP: public-domain)] Discloses a fully open-source research smartwatch combining multi-sensor vitals (PPG/SpO2/temperature/IMU), on-device ML inference, NB-IoT direct cellular connectivity (no phone required), and integrated energy harvesting to extend battery life — published with full hardware design and firmware. Prior art for symptom-monitoring smartwatch claims reciting any of those elements from 2024. Establishes that the cellular-connected open-hardware ML-enabled smartwatch is a published research design. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-spo2, sensor-skin-temperature, sensor-accelerometer, algo-hr, algo-spo2-estimation, algo-respiratory-rate, algo-activity-classification, heart-rate, blood-oxygen. CPC: A61B 5/0006, A61B 5/02416, G16H 50/20, H04W 4/80.
“Magno M, et al. 'H-Watch: A Multi-Sensor Smart Wearable for COVID-19 Symptom Monitoring with ML and Energy Harvesting.' arXiv:2407.21501 (2024). Fully open-source smartwatch hardware + firmware for symptom monitoring: ARM Cortex-M4F MCU, on-device ML inference, NB-IoT cellular connectivity, integrated energy harvesting + battery. https://arxiv.org/abs/2407.21501 — Discloses a…”
written · p. 237 · 2024-01-01 · open
ISO/IEC (TC 121/SC 3 and IEC SC 62D) · free_wearable_corpus · en
7[Free Wearable Corpus CC0-1.0 Prior Art · ISO 80601-2-61 — particular requirements for basic safety and essential performance of pulse oximeter equipment (2011/2017) (2011-08-15, ISO/IEC (TC 121/SC 3 and IEC SC 62D), standards, other, IP: standards)] Publicly-adopted standard defining pulse oximeter equipment (a device estimating SpO2 and pulse rate from light at two or more wavelengths through perfused tissue) and the accuracy/validation requirements for it. Prior art for wearable-SpO2 claims to the extent they recite the multi-wavelength pulsatile method or the SpO2-and-pulse-rate output described here; the equipment definition and method have been a published standard since 2011 (building on the [[aoyagi-1974-two-wavelength-pulse-oximetry]] principle). Disclosed wearable sensors & endpoints: sensor-spo2, sensor-ppg, sensor-multi-wavelength-ppg, algo-spo2-estimation, blood-oxygen, pulse-rate. CPC: A61B 5/1455, A61B 5/14551, A61B 5/02416.
“ISO 80601-2-61:2011 (revised 2017). 'Medical electrical equipment — Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment.' ISO, 2011. — Publicly-adopted standard defining pulse oximeter equipment (a device estimating SpO2 and pulse rate from light at two or more wavelengths through perfused tissue) and the accuracy/validatio…”
written · p. 155 · 2011-08-15 · open
Masimo Corp. · free_wearable_corpus · en
8[Free Wearable Corpus CC0-1.0 Prior Art · Masimo W1 (2022) — first FDA-cleared continuous wrist medical-grade pulse oximetry watch (2022-05, Masimo Corp., private, watch, IP: patented)] Discloses a wrist-worn device performing continuous medical-grade pulse oximetry — SpO2, PR, perfusion index, PVi, RR-from-PPG, HRV — using established signal-extraction methods, distinguished from consumer spot-check SpO2 by continuous operation and clearance for medical use. Anticipates wrist-continuous-medical-SpO2 claims from 2022; the underlying two-wavelength SpO2 method is much older ([[aoyagi-1974-two-wavelength-pulse-oximetry]], [[mendelson-ochs-1988-reflectance-pulse-oximetry]], [[iso-80601-2-61-pulse-oximeter-equipment-2011]]). Product-side anchor for the watch × continuous-SpO2 cross-cut. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-spo2, sensor-multi-wavelength-ppg, sensor-accelerometer, algo-spo2-estimation, algo-hr, algo-hrv, algo-respiratory-rate, blood-oxygen, heart-rate. CPC: A61B 5/14552, A61B 5/02416, A61B 5/1455, A61B 5/746.
“Masimo Corp. 'Masimo W1' health-tracking watch, announced May 2022 — a wrist-worn device performing continuous medical-grade pulse oximetry (SpO2), pulse rate, perfusion index (PI), pleth variability index (PVi), respiratory rate from the PPG, and HRV, using Masimo's SET/rainbow signal-extraction algorithms. (FDA cleared as a continuous-monitoring medical device.) — Discloses…”
written · p. 215 · 2022-05-01 · open
Yitzhak Mendelson / Burt D. Ochs · free_wearable_corpus · en
9[Free Wearable Corpus CC0-1.0 Prior Art · Mendelson & Ochs (1988) — reflectance-mode pulse oximetry / skin-reflectance PPG (1988-10, Yitzhak Mendelson / Burt D. Ochs, academic, other, IP: public-domain)] Establishes pulse oximetry by reflectance (light source and detector on the same side of the tissue) rather than transmission — the geometry every wrist, forehead, ring, chest, and earbud PPG/SpO2 wearable uses, since those sites cannot be transilluminated. Any wearable-SpO2 claim reciting 'a reflectance photoplethysmography sensor' or 'a light source and photodetector arranged on a common surface against the skin' reads on Mendelson & Ochs 1988. Anchor for the reflectance-PPG/SpO2 cross-cut on non-fingertip sites. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-spo2, sensor-multi-wavelength-ppg, algo-spo2-estimation, algo-hr, blood-oxygen, heart-rate. CPC: A61B 5/14552, A61B 5/02427, A61B 5/1455.
“Mendelson Y, Ochs BD. 'Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography.' IEEE Transactions on Biomedical Engineering 1988;35(10):798-805. — Establishes pulse oximetry by reflectance (light source and detector on the same side of the tissue) rather than transmission — the geometry every wrist, forehead, ring, chest, and earbud PPG/SpO2 wearable uses,…”
written · p. 171 · 1988-10-01 · open
Salar Motlaqolahi · free_wearable_corpus · en
10[Free Wearable Corpus CC0-1.0 Prior Art · Open-Watch (Salar Motlaqolahi, 2021) — fully documented open STM32 smartwatch (BSc thesis) (2021, Salar Motlaqolahi, open, watch, IP: open-permissive)] Discloses, as an MIT-licensed open-hardware smartwatch with full PCB design files (4-layer, PCBWay-sponsored fabrication) and firmware published, a wrist-worn device with reflectance PPG + SpO2 + 6-axis IMU + MCU + display. Demonstrates that the entire smartwatch design — schematic, layout, firmware — can be reproduced from undergraduate-thesis-level public work, defeating any claim that the integrated smartwatch is novel as a combination. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-spo2, sensor-accelerometer, sensor-gyroscope, algo-hr, algo-spo2-estimation, algo-step-count, heart-rate, blood-oxygen, wrist. CPC: A61B 5/02416, A61B 5/14552, A61B 5/1118, G04G 21/04.
“Motlaqolahi S. 'Open-Watch' — fully open-source smartwatch released as BSc thesis output (MIT license). Hardware: STM32 ARM Cortex-M MCU, MPU6050 6-axis IMU, MAX30102 reflectance PPG + SpO2, 4-layer PCB sponsored by PCBWay, full schematics + Gerbers + firmware published. https://github.com/SMotlaq/open-watch — Discloses, as an MIT-licensed open-hardware smartwatch with full PC…”
written · p. 231 · 2021-01-01 · open
John G. Webster (ed.) · free_wearable_corpus · en
11[Free Wearable Corpus CC0-1.0 Prior Art · Webster (ed.) (1997) — 'Design of Pulse Oximeters' (1997, John G. Webster (ed.), academic, other, IP: public-domain)] The standard engineering reference on pulse oximeter design as of 1997 — LED selection and drive, photodiode front-ends, the ratio-of-ratios calibration, motion-artifact handling, low-perfusion behavior, calibration-curve construction. Prior art for wearable-SpO2 claims to the extent they recite implementation details (wavelength choice, AC/DC ratio computation, calibration-curve mapping, artifact rejection) covered here; these were textbook-level public knowledge by 1997. Disclosed wearable sensors & endpoints: sensor-spo2, sensor-ppg, algo-spo2-estimation, algo-hr, blood-oxygen, heart-rate. CPC: A61B 5/1455, A61B 5/14551, A61B 5/02416.
“Webster JG (ed). 'Design of Pulse Oximeters.' Series in Medical Physics and Biomedical Engineering, IOP Publishing / Institute of Physics, 1997. ISBN 0-7503-0467-7. — The standard engineering reference on pulse oximeter design as of 1997 — LED selection and drive, photodiode front-ends, the ratio-of-ratios calibration, motion-artifact handling, low-perfusion behavior, calibrat…”
written · p. 172 · 1997-01-01 · open
Withings SA · free_wearable_corpus · en
12[Free Wearable Corpus CC0-1.0 Prior Art · Withings ScanWatch (2020) — hybrid analog watch with PPG, SpO2 pulse oximetry, single-lead ECG, and accelerometer (2020-01-05, Withings SA, private, watch, IP: patented)] Discloses a wristwatch combining reflectance-PPG heart rate, pulse-oximetry SpO2, a single-lead ECG with AF detection, accelerometry, and an altimeter, with sleep-apnea screening (from the SpO2/respiration signals) — multiple regulated cardiorespiratory measurements in one consumer watch. Anticipates multi-modal medical-smartwatch claims reciting combinations of wrist PPG-HR + wrist SpO2 + single-lead ECG from 2020. Product-side anchor for the watch × {PPG, SpO2, ECG} multi-sensor cross-cut. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-spo2, sensor-ecg, sensor-accelerometer, sensor-barometer, algo-hr, algo-spo2-estimation, algo-afib-detection, algo-arrhythmia-classification, algo-sleep-staging. CPC: A61B 5/02416, A61B 5/14552, A61B 5/318, A61B 5/4818.
“Withings (Nokia/Withings). 'ScanWatch', announced January 2020 (CE-marked 2020; FDA cleared 2022) — a hybrid analog wristwatch integrating a reflectance-PPG sensor (heart rate, irregular-rhythm screening), an SpO2 (pulse-oximetry) measurement, a single-lead ECG (back electrode plus a bezel electrode touched by the opposite hand, with AF detection), a 3-axis accelerometer, and…”
written · p. 196 · 2020-01-05 · open