detection-impedance-cytometry

24 moment(s) that assert this concept — showing 1–24 of 24

moderateTwo independent sources — corroborated, but not broadly
↣ how this spread over time →

reuse terms across this evidence: 24 openly licensed

provenance — click a node to open its encoding unit
[1] Wallace[2] Hermann[3] Reto[4] Nathan[5] NASA[6] Aber[7] Anpac[8] Wallace[9] Wallace[10] Daktari[11] Hideo[12] Drew
showing 12 of 24 moments
scholarly papers (2)
Wallace H. Coulter (Coulter Electronics, later Beckman Coulter) · openie_prior_art · en
1Coulter Principle (1953 Patent) Public Domain Status Analysis (Wallace H. Coulter (Coulter Electronics, later Beckman Coulter), 1953-10-20): Defensive entry. Wallace Coulter's original 1953 patent US2656508 covers the basic Coulter principle: passing a particle suspension through a small aperture between two electrolyte chambers and measuring the transient impedance change as each particle passes. The patent was granted 1953-10-20 and expired 1971-10-20 under then-applicable
“US2656508A USPTO grant text”
written · p. 1 · 1953-01-01 · open
Hermann von Helmholtz · openie_prior_art · en
2Helmholtz 1879 — Electrical Double Layer and Electroosmosis (Hermann von Helmholtz, 1879): Discloses the electrical-double-layer concept that anchors all electrokinetic microfluidic phenomena: electroosmotic flow, electrophoresis, streaming potential, sedimentation potential, dielectrophoresis (in part). Predates Smoluchowski 1903's quantitative slip-velocity by 24 years. Anticipates broad patent claims to 'voltage-controlled flow', 'surface-charge-modulated transport', or 's
“Ann. Phys. Chem. 243, 337 (1879) doi:10.1002/andp.18792430702”
written · p. 1 · 1879-01-01 · open
Reto B. Schoch; Jongyoon Han; Philippe Renaud · openie_prior_art · en
3Schoch 2008 — Transport Phenomena in Nanofluidics (Rev. Mod. Phys.) (Reto B. Schoch; Jongyoon Han; Philippe Renaud, 2008-07): Schoch 2008 in Reviews of Modern Physics is THE canonical review of nanofluidic transport prior to 2008. Catalogs: ion-selectivity in overlapping double layers, ionic-current rectification (asymmetric nanopores), concentration-polarization induced by ion-selective interfaces, electroosmotic and electrophoretic transport in nanochannels, biomolecule sen
“Rev. Mod. Phys. 80, 839 (2008) doi:10.1103/RevModPhys.80.839”
written · p. 1 · 2008-01-01 · open
Nathan S. Swami group (Univ. Virginia) with Air Force Research Laboratory aptamer collaborators · openie_prior_art · en
4Yu Lab Aptamer-Functionalized Saliva Cortisol Microfluidic Sensor (Nathan S. Swami group (Univ. Virginia) with Air Force Research Laboratory aptamer collaborators, 2014): Discloses an aptamer-functionalized impedimetric microfluidic chip for cortisol detection in saliva, with AC electrokinetic sample focusing to overcome the low salivary cortisol concentration. Anticipates: aptamer-based salivary cortisol point-of-care chips; AC-electrokinetic preconcentration coupled to apta
“Sanghavi BJ et al. Biosens Bioelectron 2015 doi:10.1016/j.bios.2015.11.052”
written · p. 1 · 2014-01-01 · open
NASA Johnson Space Center / Oxford Nanopore Technologies / Houston Methodist · openie_prior_art · en
5ISS Biomolecule Sequencer (Oxford Nanopore MinION on ISS) (NASA Johnson Space Center / Oxford Nanopore Technologies / Houston Methodist, 2016): While the underlying MinION is already covered as 'oxford-nanopore-minion' in the corpus, the spaceflight variant is independent prior art for: (a) the qualification of biological-membrane nanopore arrays for the orbital radiation environment without measurable loss of yield (vs. ground controls), which anticipates patents claiming ra
“Castro-Wallace SL et al., Sci Rep 7:18022 (2017)”
written · p. 1 · 2016-01-01 · open
Aber Instruments Ltd. (UK; partnered with Hamilton Bonaduz AG for Incyte) · openie_prior_art · en
6Aber Instruments Incyte (Hamilton Incyte) Capacitance Probe (Aber Instruments Ltd. (UK; partnered with Hamilton Bonaduz AG for Incyte)): Aber Instruments Incyte (Hamilton Incyte) Capacitance Probe [Subsystems: detection-impedance-cytometry, architecture-process-analytical-technology, interface-electrode-integration; CPC: G01N 27/22, C12M 41/00, C12Q 1/06]
“Aber Instruments Futura biomass monitor (predecessor) ~2000; Incyte single-use capacitance probe launched as joint Aber/Hamilton product ~2008; US patent US7,930,110B2 (Aber Instruments; biomass monitor based on dielectric spectroscopy); pr”
written · p. 1 · 2026-05-01 · open
Anpac Bio-Medical Science · openie_prior_art · en
7Anpac Biomedical CDA patent family (Anpac Bio-Medical Science): Anpac Biomedical CDA patent family [Subsystems: detection-electrochemical-on-chip, detection-impedance-cytometry; CPC: ]
“Anpac Bio-Medical Science (Lishui, Shanghai) IP estate (2008-present); CN/US/PCT filings”
written · p. 1 · 2026-05-01 · open
Wallace H. Coulter (assigned later to Coulter Electronics, now Beckman Coulter / Danaher) · openie_prior_art · en
8Wallace H. Coulter 1953 Impedance Particle/Cell Counting Patent (Coulter Principle) (Wallace H. Coulter (assigned later to Coulter Electronics, now Beckman Coulter / Danaher)): Wallace H. Coulter 1953 Impedance Particle/Cell Counting Patent (Coulter Principle) [Subsystems: pump-pressure-controlled-air-over-liquid, detection-impedance-cytometry, interface-electrode-integration, fabrication-glass-hf-etching; CPC: G01N 15/12, G01N 27/447]
“Coulter, W.H. US patent application filed 1949-10-20, US2656508A issued 1953-10-20, 'Means for counting particles suspended in a fluid'; Coulter, W.H. 'High speed automatic blood cell counter and cell size analyzer,' Proc. National Electron”
written · p. 1 · 1953-01-01 · open
Wallace H. Coulter (Coulter Electronics, later Beckman Coulter) · openie_prior_art · en
9Coulter Principle (1953 Patent) Public Domain Status Analysis (Wallace H. Coulter (Coulter Electronics, later Beckman Coulter)): Coulter Principle (1953 Patent) Public Domain Status Analysis [Subsystems: detection-impedance-cytometry; CPC: G01N 15/12]
“US2656508 (Wallace H. Coulter, granted 1953-10-20, expired 1971-10-20); existing entry coulter-1953-impedance-cell-counting-patent”
written · p. 1 · 1953-01-01 · open
Daktari Diagnostics Inc. (defunct ~2018) · openie_prior_art · en
10Daktari Diagnostics CD4 Counter (defunct) (Daktari Diagnostics Inc. (defunct ~2018)): Daktari Diagnostics CD4 Counter (defunct) [Subsystems: separation-affinity-capture, detection-impedance-cytometry, interface-blister-pack-reagent-storage, architecture-stat-test-cartridge; CPC: G01N 33/53, B01L 3/00]
“Cheng X et al., Lab on a Chip 7:170-178 (2007); Watkins NN et al., Sci Transl Med 5:214ra170 (2013); Daktari Diagnostics product literature; FDA 510(k) K130725”
written · p. 1 · 2026-05-01 · open
Hideo Kojima / Kojima Productions · openie_prior_art · en
11Death Stranding Bridge Baby (BB) pod and chiral-fluid life support (Hideo Kojima / Kojima Productions): Death Stranding Bridge Baby (BB) pod and chiral-fluid life support [Subsystems: architecture-on-chip-incubator, cell-organoid-perfusion, detection-impedance-cytometry, interface-luer-lock-port; CPC: ]
“Death Stranding (Kojima Productions/Sony 2019); Director's Cut (2021).”
written · p. 1 · 2026-05-01 · open
Drew Scientific (Erba Diagnostics) · openie_prior_art · en
12Drew Scientific HemaVet 950 / 1500 Veterinary Hematology Analyzer (Drew Scientific (Erba Diagnostics)): Drew Scientific HemaVet 950 / 1500 Veterinary Hematology Analyzer [Subsystems: pump-stepper-volumetric, detection-impedance-cytometry, fabrication-glass-hf-etching, architecture-multiplex-cartridge; CPC: G01N 15/12, G01N 33/49]
“Drew Scientific HemaVet 850/950 launch ~1996; HemaVet 1500 launch 2003; pivotal multi-species reference distribution publications by Provost, Vet Clin Pathol”
written · p. 1 · 2026-05-01 · open
Bungie / 343 Industries / Eric Nylund · openie_prior_art · en
13Halo MJOLNIR Smart-Link armor-to-medbay biotelemetry (Bungie / 343 Industries / Eric Nylund): Halo MJOLNIR Smart-Link armor-to-medbay biotelemetry [Subsystems: detection-electrochemical-on-chip, detection-impedance-cytometry; CPC: ]
“Halo: The Fall of Reach (Nylund 2001); Halo Encyclopedia (DK 2009); Halo 4 (343 Industries, 2012) on-screen Smart-Link HUD.”
written · p. 1 · 2026-05-01 · open
Hermann von Helmholtz · openie_prior_art · en
14Helmholtz 1879 — Electrical Double Layer and Electroosmosis (Hermann von Helmholtz): Helmholtz 1879 — Electrical Double Layer and Electroosmosis [Subsystems: pump-electroosmotic, separation-capillary-electrophoresis, detection-impedance-cytometry; CPC: B01L 3/502, G01N 27/447]
“Helmholtz, H. v. (1879). 'Studien ueber elektrische Grenzschichten.' Annalen der Physik und Chemie 243(7): 337-382. doi:10.1002/andp.18792430702”
written · p. 1 · 1879-01-01 · open
NASA Johnson Space Center / Oxford Nanopore Technologies / Houston Methodist · openie_prior_art · en
15ISS Biomolecule Sequencer (Oxford Nanopore MinION on ISS) (NASA Johnson Space Center / Oxford Nanopore Technologies / Houston Methodist): ISS Biomolecule Sequencer (Oxford Nanopore MinION on ISS) [Subsystems: detection-impedance-cytometry, interface-electrode-integration, architecture-stat-test-cartridge; CPC: C12Q 1/6869, G01N 33/487, B64G 1/14]
“Castro-Wallace SL et al., 'Nanopore DNA Sequencing and Genome Assembly on the International Space Station,' Scientific Reports 7:18022 (2017), doi:10.1038/s41598-017-18364-0; NASA ISS Biomolecule Sequencer mission press kit, August 2016”
written · p. 1 · 2026-05-01 · open
Izon Science Ltd. · openie_prior_art · en
16Izon Science qNano / qViro / Exoid - Tunable Resistive Pulse Sensing (Izon Science Ltd.): Izon Science qNano / qViro / Exoid - Tunable Resistive Pulse Sensing [Subsystems: detection-impedance-cytometry, separation-pinched-flow-fractionation; CPC: G01N 33/487, G01N 15/12]
“Izon Science qNano product launch, 2008; Exoid next-generation launch 2020.”
written · p. 1 · 2026-05-01 · open
OLS Bio (formerly Innovatis AG; Roche Diagnostics divestiture) · openie_prior_art · en
17OLS Bio CASY Cell Counter and Analyzer (formerly Innovatis CASY-TT) (OLS Bio (formerly Innovatis AG; Roche Diagnostics divestiture)): OLS Bio CASY Cell Counter and Analyzer (formerly Innovatis CASY-TT) [Subsystems: pump-pressure-controlled-air-over-liquid, detection-impedance-cytometry, fabrication-glass-hf-etching, interface-electrode-integration, architecture-stat-test-cartridge; CPC: G01N 15/12, G01N 33/483]
“Innovatis (Bielefeld, Germany) CASY launch 1991; CASY-TT (TwinTechnology) launch 2006; Innovatis acquired by Roche 2008; CASY product line now sold by OLS-Bio (since 2013); Pulsar Coulter-principle patent extension”
written · p. 1 · 2026-05-01 · open
Oxford Nanopore Technologies · openie_prior_art · en
18Oxford Nanopore R10.4.1 flow cell (Oxford Nanopore Technologies): Oxford Nanopore R10.4.1 flow cell [Subsystems: detection-impedance-cytometry, fabrication-silicon-drie, interface-pressure-manifold; CPC: G01N 33/487, C12Q 1/68]
“Oxford Nanopore Technologies R10.4.1 / Kit 14 release announcement at London Calling 2022, 2022-05-19. https://nanoporetech.com/.”
written · p. 1 · 2026-05-01 · open
Sartorius AG · openie_prior_art · en
19Sartorius BioPAT Process Analytical Technology Suite (Sartorius AG): Sartorius BioPAT Process Analytical Technology Suite [Subsystems: detection-impedance-cytometry, detection-raman-on-chip, detection-electrochemical-on-chip, architecture-process-analytical-technology; CPC: G05B 19/418, C12M 41/00, G01N 21/65]
“Sartorius BioPAT product line introduced ~2010 with BioPAT MFCS SCADA; BioPAT ViaMass capacitance launched 2018; Sartorius product literature 2010-2023”
written · p. 1 · 2026-05-01 · open
Reto B. Schoch; Jongyoon Han; Philippe Renaud · openie_prior_art · en
20Schoch 2008 — Transport Phenomena in Nanofluidics (Rev. Mod. Phys.) (Reto B. Schoch; Jongyoon Han; Philippe Renaud): Schoch 2008 — Transport Phenomena in Nanofluidics (Rev. Mod. Phys.) [Subsystems: separation-capillary-electrophoresis, detection-impedance-cytometry; CPC: B01L 3/502, G01N 27/447, B82Y 30/00]
“Schoch, R. B., Han, J., Renaud, P. (2008). 'Transport phenomena in nanofluidics.' Reviews of Modern Physics 80(3): 839-883. doi:10.1103/RevModPhys.80.839”
written · p. 1 · 2008-01-01 · open
Spectradyne LLC · openie_prior_art · en
21Spectradyne nCS1 / nCS2 - Microfluidic resistive pulse sensing (Spectradyne LLC): Spectradyne nCS1 / nCS2 - Microfluidic resistive pulse sensing [Subsystems: separation-pinched-flow-fractionation, detection-impedance-cytometry, detection-fluorescence-on-chip; CPC: G01N 15/12, G01N 33/487]
“Spectradyne nCS1 product launch, 2015.”
written · p. 1 · 2026-05-01 · open
Gene Roddenberry / Desilu · openie_prior_art · en
22Star Trek TOS Enterprise sickbay biobed (Gene Roddenberry / Desilu): Star Trek TOS Enterprise sickbay biobed [Subsystems: detection-impedance-cytometry; CPC: ]
“Star Trek (NBC 1966-1969); pilot 'The Cage' (1965) shows early biobed; 'The Enemy Within' (1966) shows full biobed in service.”
written · p. 1 · 2026-05-01 · open
Sysmex Corporation · openie_prior_art · en
23Sysmex XN-series hematology analyzer patent family (Sysmex Corporation): Sysmex XN-series hematology analyzer patent family [Subsystems: detection-fluorescence-on-chip, detection-impedance-cytometry, separation-affinity-capture; CPC: ]
“Sysmex XN-series product launch (Sysmex Corp 2011); JP/US/EP filings via espacenet (assignee: Sysmex)”
written · p. 1 · 2026-05-01 · open
Nathan S. Swami group (Univ. Virginia) with Air Force Research Laboratory aptamer collaborators · openie_prior_art · en
24Yu Lab Aptamer-Functionalized Saliva Cortisol Microfluidic Sensor (Nathan S. Swami group (Univ. Virginia) with Air Force Research Laboratory aptamer collaborators): Yu Lab Aptamer-Functionalized Saliva Cortisol Microfluidic Sensor [Subsystems: detection-impedance-cytometry, detection-electrochemical-on-chip, separation-dielectrophoresis, surface-functionalization-thiol-gold; CPC: G01N 27/447, G01N 33/74]
“Sanghavi BJ, Moore JA, Chávez JL, Hagen JA, Kelley-Loughnane N, Chou C-F, Swami NS, Biosens. Bioelectron. 78:244-252 (2014); doi:10.1016/j.bios.2015.11.052”
written · p. 1 · 2026-05-01 · open