gyro sensor

also known as sensing-gyroscope · sensor-gyroscope

15 moment(s) that assert this concept — showing 1–15 of 15

strong13 independent sourcescross-modal
↣ how this spread over time →

reuse terms across this evidence: 12 openly licensed · 3 undeclared

provenance — click a node to open its encoding unit
[1] Multi-vendor[2] Apple[3] Empatica[4] ProtoCentral[5] Brett[6] Microsoft[7] Mojo[8] Thalmic[9] Shyamal[10] Ernest[11] Salar[12] Ultrahuman
showing 12 of 15 moments
scholarly papers (2)
Multi-vendor MEMS lineage; Analog Devices (US) + Bosch (Germany) + InvenSense (U · free_humanoid_corpus · en
1[Free Humanoid Corpus CC0-1.0 Prior Art · MEMS IMU foundational lineage (gyroscope + accelerometer) (1991-01, Multi-vendor MEMS lineage; Analog Devices (US) + Bosch (Germany) + InvenSense (US, acquired by TDK 2017) + ST Microelectronics (Switzerland/Italy), private, end-effector-tactile, IP: trade-secret)] The MEMS IMU foundational lineage (Analog Devices 1991 + Bosch 1995 + InvenSense MPU-6050 2010 + modern multi-vendor 9-axis IMU) is the canonical robotic-grade IMU prior art. 34-year-deep public-disclosure prior art. The IMU stack running in essentially every robot + drone + smartphone. Direct shielding for any commercial humanoid claim using IMU sensing. Disclosed subs
“Analog Devices ADXL50 first commercial MEMS accelerometer 1991. Bosch MEMS gyroscope SMG020 1995+. **Foundational MEMS IMU lineage**: Analog Devices ADXL series + InvenSense MPU-6050 (2010, founded 2003) + ST Microelectronics LSM-series + Bosch BMI/BMM-series. The MEMS IMU revolution drove the smartphone + drone + robot consumer-IMU era. ”
written · p. 578 · 1991-01-01 · open
Apple Inc. · free_wearable_corpus · en
2[Free Wearable Corpus CC0-1.0 Prior Art · Apple Watch (1st generation, 2015) — wrist green-PPG heart rate and activity (2015-04-24, Apple Inc., private, watch, IP: patented)] Discloses a wristworn device with a dorsal-wrist green-LED photoplethysmography heart-rate sensor (with IR for low-perfusion conditions), inertial sensors, and continuous HR/activity tracking. Anticipates wristworn-PPG-HR claims to the extent they postdate April 2015; combined with the much earlier PPG principle ([[hertzman-1937-photoplethysmography]]) and wrist form factor, the combination is in any case obvious under [[obviousness-template]]. Product-side anchor for the watch × PPG cross-cut. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-multi-wavelength-ppg, sensor-accelerometer, sensor-gyroscope, algo-hr, algo-step-count, algo-calorie-estimation, algo-activity-classification, heart-rate, activity. CPC: A61B 5/02416, A61B 5/681, A61B 5/1118, G04G 21/04.
“Apple Inc. 'Apple Watch', announced September 2014, available 24 April 2015 — a wrist-worn device with a green/infrared photoplethysmography heart-rate sensor against the dorsal wrist, accelerometer and gyroscope, and activity/exercise tracking. — Discloses a wristworn device with a dorsal-wrist green-LED photoplethysmography heart-rate sensor (with IR for low-perfusion condit…”
written · p. 160 · 2015-04-24 · open
Empatica Inc. (Rosalind Picard, Matteo Lai, et al.) · free_wearable_corpus · en
3[Free Wearable Corpus CC0-1.0 Prior Art · Empatica Embrace2 (2018) — first FDA-cleared seizure-monitoring smartwatch (accelerometer + electrodermal activity) (2018-01-31, Empatica Inc. (Rosalind Picard, Matteo Lai, et al.), private, watch, IP: patented)] Discloses a wristworn device that detects probable generalized tonic-clonic seizures by combining a motion (accelerometer/gyroscope) signature with an electrodermal-activity (sympathetic-surge) signature in an on-device classifier, and alerts caregivers — i.e. multimodal wrist-based seizure detection, distinct from the EEG-based approach. Anticipates wrist-seizure-detection claims combining 'a wrist-worn accelerometer and an electrodermal-activity sensor' and 'a classifier flagging a seizure from their combined signal' from 2018. Product-side anchor for the wrist × seizure-detection cross-cut; complementary to the EEG route in [[zanetti-aminifar-atienza-eglass-2025]] and [[chb-mit-scalp-eeg-database-2009]]. Disclosed wearable sensors & endpoints: sensor-accelerometer, sensor-gyroscope, sensor-gsr, sensor-skin-temperature, algo-seizure-detection, algo-stress-index, algo-activity-classification, seizure-event, electrodermal-activity, skin-temperature. CPC: A61B 5/4094, A61B 5/0531, A61B 5/1117, A61B 5/01.
“Empatica Inc. 'Embrace2' smartwatch, FDA-cleared January 2018 — a wrist-worn device with a 3-axis accelerometer/gyroscope, an electrodermal-activity (EDA) sensor, and a peripheral skin-temperature sensor, running an on-device classifier that detects probable generalized tonic-clonic seizures from the combined motion + EDA signature and alerts caregivers; the first FDA-cleared…”
written · p. 197 · 2018-01-31 · open
ProtoCentral Electronics · free_wearable_corpus · en
4[Free Wearable Corpus CC0-1.0 Prior Art · HealthyPi Move (ProtoCentral, 2026) — open-source medical-grade smartwatch (2024, ProtoCentral Electronics, open, watch, IP: open-permissive)] Discloses, as fully open-source hardware and firmware (CC and MIT-style licensing across components), a wrist-worn smartwatch with the full consumer-medical sensor stack: single-lead ECG between back-of-watch electrode and a finger-touch electrode; multi-wavelength reflectance PPG with SpO2 and BP-trending; EDA/GSR; skin temperature; 6-axis IMU; on-device Zephyr-RTOS application; AMOLED display; all-local data storage via cross-platform Flutter app. Anticipates wrist-multi-sensor-watch claims from 2024-2026 to the extent they recite combinations of these elements; as `open` prior art it is unencumbered and any patent claim reciting these combinations must distinguish over HealthyPi Move's specific implementation. The product-side anchor for the 'open watch with the full sensor stack' cross-cut. Disclosed wearable sensors & endpoints: sensor-ecg, sensor-ppg, sensor-spo2, sensor-multi-wavelength-ppg, sensor-gsr, sensor-accelerometer, sensor-gyroscope, sensor-skin-temperature, algo-hr, algo-hrv. CPC: A61B 5/0006, A61B 5/02416, A61B 5/318, A61B 5/14552, G04G 21/04.
“ProtoCentral Electronics (Bengaluru, India). 'HealthyPi Move' fully open-source AMOLED smartwatch — Crowd Supply campaign launched 2024, units shipping 15 May 2026. Sensors: single-lead ECG, dual-site PPG (wrist + finger), SpO2, blood-pressure trending, EDA/GSR, heart rate, HRV, respiration rate (derived), body temperature, 6-axis IMU. Compute: Nordic nRF5340 (dual ARM Cortex-…”
written · p. 228 · 2024-01-01 · open
Brett Leonard / Allied Vision / New Line Cinema · free_wearable_corpus · en
5[Free Wearable Corpus CC0-1.0 Prior Art · The Lawnmower Man — VR rig (gyro chair, headset, full-body cybersuit) (1992-03-06, Brett Leonard / Allied Vision / New Line Cinema, fictional, garment, IP: fictional)] Reference-only. An early integrated VR rig — head-mounted display plus a full-body motion-capturing, sensation-conveying suit — a thin antecedent for full-body VR-suit-plus-HMD claims. Contributes to the garment cross-cut; predates [[ready-player-one-haptic-suit]] (2011) and [[sao-nervegear]] (2009). Disclosed wearable sensors & endpoints: sensor-accelerometer, sensor-gyroscope, whole-body. CPC: G06F 3/01, A41D 1/00, G02B 27/01.
“The Lawnmower Man (New Line Cinema), released 6 March 1992; a virtual-reality rig comprising a motorized gyroscopic chair, a head-mounted display, and a full-body 'cybersuit' that tracks the wearer's movements and conveys virtual sensations. — Reference-only. An early integrated VR rig — head-mounted display plus a full-body motion-capturing, sensation-conveying suit — a thin…”
written · p. 122 · 1992-03-06 · open
Microsoft Corp. · free_wearable_corpus · en
6[Free Wearable Corpus CC0-1.0 Prior Art · Microsoft Band (2014) — ten-sensor wristband (optical HR, GPS, GSR, UV, skin temp, barometer, ambient light, capacitive, microphone, IMU) (2014-10-30, Microsoft Corp., private, watch, IP: patented)] Discloses a single wristband integrating an unusually broad sensor suite — reflectance-PPG HR, IMU, GPS, skin temperature, UV exposure, galvanic skin response (electrodermal activity), barometer, ambient light, capacitive wear-detection, and a microphone — feeding HR, activity, sleep, UV dose, and stress-index estimations. Prior art for multi-sensor-wristband claims reciting combinations of these sensors (notably wrist GSR/EDA + PPG + skin temperature for stress) from October 2014. Product-side anchor for the multi-sensor wristband cross-cut. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-accelerometer, sensor-gyroscope, sensor-skin-temperature, sensor-uv, sensor-gsr, sensor-barometer, sensor-photodiode-ambient, sensor-microphone-air, algo-hr. CPC: A61B 5/02438, A61B 5/0531, A61B 5/01, A61B 5/1118.
“Microsoft Corp. 'Microsoft Band', released 30 October 2014 — a wristband integrating ten sensors: an optical (PPG) heart-rate sensor, a 3-axis accelerometer/gyroscope, GPS, an ambient-light sensor, a skin-temperature sensor, a UV sensor, a capacitive (wear-detection) sensor, a galvanic-skin-response sensor, a microphone, and a barometer (added in Band 2). — Discloses a single…”
written · p. 190 · 2014-10-30 · open
Mojo Vision, Inc. · free_wearable_corpus · en
7[Free Wearable Corpus CC0-1.0 Prior Art · Mojo Vision Mojo Lens (2022) — wearable AR contact lens with embedded microLED display (2022-06, Mojo Vision, Inc., private, contact-lens, IP: patented)] Discloses a contact lens with an embedded microLED display in the central visual field, on-lens processing, gaze tracking via inertial/magnetic sensors, wireless RF link, and a wirelessly charged on-lens battery — i.e. an AR display contact lens worn on the cornea. Anticipates AR-contact-lens claims combining 'a contact lens', 'an embedded near-eye microdisplay', 'on-lens processing and motion sensors for gaze', and 'a wireless link' from 2022. Product-side anchor for the contact-lens × visual-display cross-cut; cf. [[rainbows-end-ar-contact-lens]] (the 2006 fictional anticipation). Disclosed wearable sensors & endpoints: sensor-accelerometer, sensor-gyroscope, sensor-magnetometer, algo-eye-gaze-tracking, cornea, sclera. CPC: G02C 7/04, G02B 27/01, G06F 3/01, A61B 3/113.
“Mojo Vision, Inc. 'Mojo Lens', publicly demonstrated June 2022 — a scleral contact lens with an embedded ~14k-PPI microLED display in the wearer's central field of view, an ARM Cortex processor, eye-tracking via motion sensors, a magnetometer for gaze direction, a microwave radio for offload, and a wirelessly charged battery; rendering an AR information overlay on the cornea.…”
written · p. 224 · 2022-06-01 · open
Thalmic Labs Inc. (later North) · free_wearable_corpus · en
8[Free Wearable Corpus CC0-1.0 Prior Art · Thalmic Labs Myo armband (2014) — consumer surface-EMG gesture-control armband (2013-02-25, Thalmic Labs Inc. (later North), private, armband, IP: patented)] Discloses a forearm-worn band with an array of eight surface-EMG electrodes plus a 9-axis IMU that recognizes hand/finger gestures from forearm-muscle EMG combined with arm motion/orientation and transmits them wirelessly as a control input. A consumer realization of the myoelectric pattern-recognition approach ([[englehart-hudgins-2003-myoelectric-control]]); anticipates EMG-gesture-armband claims combining 'a band of surface-EMG electrodes worn around the forearm', 'an inertial sensor', and 'a classifier mapping the combined signal to a hand gesture / control command' from 2014. Product-side anchor for the armband × EMG cross-cut (the only `armband` form-factor entry besides [[mass-effect-omni-tool]] and [[fallout-pip-boy]]). Disclosed wearable sensors & endpoints: sensor-emg, sensor-accelerometer, sensor-gyroscope, sensor-magnetometer, algo-hand-gesture-emg, algo-keystroke-emg, electromyogram, gesture-class, arm-orientation, forearm. CPC: A61B 5/389, G06F 3/015, G06F 3/017, A61B 5/1118.
“Thalmic Labs Inc. 'Myo gesture control armband', announced February 2013, shipped 2014 — a forearm-worn band of eight medical-grade stainless-steel surface-EMG electrode segments plus a 9-axis IMU, recognizing hand and finger gestures from the forearm-muscle electrical activity and arm orientation/motion, and transmitting them over Bluetooth as input to computers/devices. — Di…”
written · p. 201 · 2013-02-25 · open
Shyamal Patel / Hyung Park / Paolo Bonato et al. · free_wearable_corpus · en
9[Free Wearable Corpus CC0-1.0 Prior Art · Patel et al. (2012) — 'A review of wearable sensors and systems with application in rehabilitation' (2012-04-20, Shyamal Patel / Hyung Park / Paolo Bonato et al., academic, other, IP: public-domain)] Reviews, as of 2012, wearable inertial/EMG/pressure sensor systems for movement and physiological monitoring in rehabilitation and chronic-disease management — gait analysis, activity and posture classification, fall detection, tremor and bradykinesia quantification (Parkinson's), with the sensor placements (foot/insole, shank, thigh, trunk, wrist, forearm) and algorithms. Prior art for wearable movement-disorder and gait-monitoring claims reciting any of the placements/analytics surveyed; collected and published by 2012. General anchor for the gait / tremor / activity cross-cuts. Disclosed wearable sensors & endpoints: sensor-accelerometer, sensor-gyroscope, sensor-emg, sensor-ecg, sensor-ppg, sensor-pressure-skin, algo-gait-analysis, algo-activity-classification, algo-fall-detection, algo-tremor-detection. CPC: A61B 5/1124, A61B 5/1101, A61B 5/4082, A61B 5/1117.
“Patel S, Park H, Bonato P, Chan L, Rodgers M. 'A review of wearable sensors and systems with application in rehabilitation.' Journal of NeuroEngineering and Rehabilitation 2012;9:21. — Reviews, as of 2012, wearable inertial/EMG/pressure sensor systems for movement and physiological monitoring in rehabilitation and chronic-disease management — gait analysis, activity and postur…”
written · p. 187 · 2012-04-20 · open
Ernest Cline · free_wearable_corpus · en
10[Free Wearable Corpus CC0-1.0 Prior Art · Ready Player One full-body haptic suit and visor (2011-08-16, Ernest Cline, fictional, garment, IP: fictional)] Discloses an integrated VR rig: a near-eye display visor plus a full-body garment with distributed haptic actuators and distributed motion sensors, providing whole-body force/tactile feedback registered to a virtual environment and capturing the wearer's posture and gestures. Relevant to haptic-garment claims combining 'a body-worn garment', 'an array of haptic actuators at multiple body sites', 'motion sensors capturing body pose', and 'coupling to a head-mounted display'. § 103 motivation that the full-body haptic VR suit was an articulated objective by 2011. Disclosed wearable sensors & endpoints: sensor-accelerometer, sensor-gyroscope, haptic-eccentric, haptic-piezo. CPC: G06F 3/01, A41D 1/00, G02B 27/01.
“Cline, Ernest. Ready Player One. Crown Publishers, 2011 — a head-mounted VR visor plus a full-body haptic-feedback suit (with haptic gloves and boots) that renders touch sensations across the wearer's body and tracks body motion for immersive virtual presence. — Discloses an integrated VR rig: a near-eye display visor plus a full-body garment with distributed haptic actuators…”
written · p. 29 · 2011-08-16 · open
Salar Motlaqolahi · free_wearable_corpus · en
11[Free Wearable Corpus CC0-1.0 Prior Art · Open-Watch (Salar Motlaqolahi, 2021) — fully documented open STM32 smartwatch (BSc thesis) (2021, Salar Motlaqolahi, open, watch, IP: open-permissive)] Discloses, as an MIT-licensed open-hardware smartwatch with full PCB design files (4-layer, PCBWay-sponsored fabrication) and firmware published, a wrist-worn device with reflectance PPG + SpO2 + 6-axis IMU + MCU + display. Demonstrates that the entire smartwatch design — schematic, layout, firmware — can be reproduced from undergraduate-thesis-level public work, defeating any claim that the integrated smartwatch is novel as a combination. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-spo2, sensor-accelerometer, sensor-gyroscope, algo-hr, algo-spo2-estimation, algo-step-count, heart-rate, blood-oxygen, wrist. CPC: A61B 5/02416, A61B 5/14552, A61B 5/1118, G04G 21/04.
“Motlaqolahi S. 'Open-Watch' — fully open-source smartwatch released as BSc thesis output (MIT license). Hardware: STM32 ARM Cortex-M MCU, MPU6050 6-axis IMU, MAX30102 reflectance PPG + SpO2, 4-layer PCB sponsored by PCBWay, full schematics + Gerbers + firmware published. https://github.com/SMotlaq/open-watch — Discloses, as an MIT-licensed open-hardware smartwatch with full PC…”
written · p. 231 · 2021-01-01 · open
Ultrahuman Healthcare Pvt. Ltd. · free_wearable_corpus · en
12[Free Wearable Corpus CC0-1.0 Prior Art · Ultrahuman Ring AIR (2023) — smart ring with metabolic-focus tracking (PPG, skin temperature, IMU) (2023, Ultrahuman Healthcare Pvt. Ltd., private, ring, IP: patented)] Discloses a smart ring with IR PPG, skin-temperature, and a 6-axis IMU, deriving HR/HRV, sleep, and activity, packaged with a metabolic-health platform (CGM-linked). Product-side reference in the ring × PPG cross-cut alongside [[oura-ring-gen1-2015]] and [[samsung-galaxy-ring-2024]]. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-skin-temperature, sensor-accelerometer, sensor-gyroscope, algo-hr, algo-hrv, algo-sleep-staging, algo-respiratory-rate, heart-rate, heart-rate-variability. CPC: A61B 5/02427, A61B 5/01, A61B 5/4812, A61B 5/681.
“Ultrahuman Healthcare Pvt. Ltd. 'Ultrahuman Ring AIR', launched 2023 — a titanium smart ring with infrared photoplethysmography, IR skin-temperature, and a 6-axis IMU, deriving HR, HRV, skin temperature, sleep staging, activity, and metabolic-health framing (paired with the company's CGM-based metabolism platform). — Discloses a smart ring with IR PPG, skin-temperature, and a…”
written · p. 219 · 2023-01-01 · open
James Lambert · youtube · en
13The Oculus DK1 headset uses an accelerometer, magnetometer, and gyro sensor to determine orientation, and combining these sensors provides sufficient data to estimate headset orientation in real time.
“it has an accelerometer a magnom and a gyro and each provides some useful information and when combined can determine the orientation of the headset at any given time so for instance the accelerometer can tell which direction gravity is pointing the magnetometer can determine which direction Earth's magnetic field is pointing and since two vectors that aren't parallel are enough”
spoken · 219s · 2024-03-07
James Lambert · youtube · en
14The gravity vector lags behind actual orientation due to filtering, which is corrected using gyro sensor data.
“this also has the unfortunate side effect of making the gravity Vector lag pretty far behind its actual orientation this is where the gyro sensor data comes in”
spoken · 281s · 2024-03-07
James Lambert · youtube · en
15Gyro data is used to rotate the gravity vector obtained from the accelerometer, preventing significant lag.
“I use this information to rotate the gravity Vector obtained by the accelerometer this prevents the gravity Vector from lagging behind too much”
spoken · 290s · 2024-03-07