lateral force

also known as lateral forces

7 moment(s) that assert this concept — showing 1–7 of 7

strong4 independent sources
↣ how this spread over time →
provenance — click a node to open its encoding unit
[1] Christoph[2] James[3] NS[4] The[5] The[6] The[7] The
showing 7 of 7 moments
Christoph Laimer · youtube · en-US
1The threaded rods in the motor design clamp the Stater Mount pieces together and provide reinforcement against lateral forces on the shaft.
“the four threaded rods not only clamp the two pieces of the Stater Mount together but they also serve as a reinforcement for lateral forces executed to the shaft”
spoken · 285s · 2017-05-03
James Bruton · youtube · en-US
2All four motors must operate simultaneously to provide lateral stability and rotational balance
“the balls all four Motors going sideways”
spoken · 413s · 2025-01-21
NS Builders · youtube · en-US
3Lateral forces in high-wind zones with large glass walls necessitate engineering review beyond standard prescriptive design.
“you have a lot of glass in tall walls like that's not prescriptive single-family home design”
spoken · 431s · 2023-02-01
The B1M · youtube · en
4A skyscraper with a height-to-width ratio of 9.5 to 1 exceeds China's seismic code limit and was designed to resist lateral forces despite being highly susceptible to them
“golden Finance 117 was to be topped with a three-story diamond shaped atrium which would have been home to the world's highest observation deck, pool, restaurant and sky bar; the building was to be habitable up to its highest point, and its height-to-width ratio of 9.5 to 1 exceeded the limit set by China's seismic code”
spoken · 70s · 2023-11-12
The B1M · youtube · en
5A building with a 197 hotel floors and 128 commercial floors above ground is designed to resist lateral forces through a perimeter frame of tapering mega columns, mega braces, and transfer trusses supported by a full-height reinforced concrete core
“golden Finance 117 was designed with a perimeter frame consisting of tapering mega columns, mega braces and transfer trusses all supported by and tied back to a full height reinforced concrete core creating a near immovable structure”
spoken · 608s · 2023-11-12
The B1M · youtube · en
6Golden Finance 117 was designed to resist lateral forces and had a height-to-width ratio of 9.5 to 1, exceeding China's seismic code requirements.
“exceeding the limit set by China's seismic code the building should have been highly susceptible to lateral forces but it was designed to resist them”
spoken · 708s · 2023-11-12
The B1M · youtube · en
7Golden Finance 117 was designed with a perimeter frame and reinforced concrete core to resist lateral forces.
“Golden Finance 117 was designed with a perimeter frame consisting of tapering Mega columns Mega braces and transfer trusses all supported by and tied back to a full height reinforced concrete core”
spoken · 723s · 2023-11-12