sensor-cuffless-bp-ptt
4 moment(s) that assert this concept — showing 1–4 of 4
strong4 independent sources
↣ how this spread over time →reuse terms across this evidence: 4 openly licensed
scholarly papers (1)
Aktiia SA · free_wearable_corpus · en
1[Free Wearable Corpus CC0-1.0 Prior Art · Aktiia bracelet (2021) — optical-PPG-based continuous cuffless blood-pressure monitoring bracelet (2021-01, Aktiia SA, private, bracelet, IP: patented)] Discloses a slim wristband that, after a one-time cuff initialization (and periodic re-calibration), automatically estimates systolic and diastolic blood pressure multiple times per day and night purely from the wrist optical-PPG pulse waveform — i.e. continuous, fully cuffless, calibration-initialized wrist BP monitoring. Anticipates continuous-cuffless-wrist-BP claims from 2021; the PPG-pulse-feature-to-BP mapping rests on the much older PTT/PWV-BP and pulse-contour literature ([[geddes-1981-pulse-transit-time-bp]], [[mukkamala-2015-ptt-cuffless-bp-review]]). Product-side anchor for the bracelet × cuffless-BP cross-cut. Disclosed wearable sensors & endpoints: sensor-ppg, sensor-cuffless-bp-ptt, sensor-accelerometer, algo-pwv-bp-estimation, algo-hr, blood-pressure, heart-rate, wrist. CPC: A61B 5/02125, A61B 5/021, A61B 5/02416, A61B 5/681.
“Aktiia SA. 'Aktiia bracelet' (later 'Hilo'), CE-marked and launched in Europe January 2021 — a slim wristband with optical photoplethysmography that, after a one-time initialization against a conventional cuff (and periodic re-calibration), estimates systolic and diastolic blood pressure several times a day automatically, day and night, from the wrist PPG pulse waveform. — Dis…”
written · p. 195 · 2021-01-01 · open
Leslie A. Geddes et al. (Purdue) · free_wearable_corpus · en
2[Free Wearable Corpus CC0-1.0 Prior Art · Geddes et al. (1981) — pulse transit time as an indicator of arterial blood pressure (1981-01, Leslie A. Geddes et al. (Purdue), academic, other, IP: public-domain)] Establishes that pulse transit time — the delay between a proximal timing reference (e.g. the ECG R-wave) and the arrival of the pulse at a distal site (e.g. a finger PPG) — varies inversely with arterial blood pressure, and can therefore be used to estimate BP without a cuff. Any cuffless-BP wearable claim reciting 'estimating blood pressure from a pulse transit time (or pulse arrival time / pulse wave velocity) derived from two physiological signals' reads on Geddes 1981. Earliest anchor for the PTT-cuffless-BP cross-cut; [[mukkamala-2015-ptt-cuffless-bp-review]] is the modern survey. Disclosed wearable sensors & endpoints: sensor-ecg, sensor-ppg, sensor-cuffless-bp-ptt, algo-pwv-bp-estimation, blood-pressure. CPC: A61B 5/02125, A61B 5/02108, A61B 5/021.
“Geddes LA, Voelz MH, Babbs CF, Bourland JD, Tacker WA. 'Pulse transit time as an indicator of arterial blood pressure.' Psychophysiology 1981;18(1):71-74. — Establishes that pulse transit time — the delay between a proximal timing reference (e.g. the ECG R-wave) and the arrival of the pulse at a distal site (e.g. a finger PPG) — varies inversely with arterial blood pressure, a…”
written · p. 174 · 1981-01-01 · open
Ramakrishna Mukkamala et al. · free_wearable_corpus · en
3[Free Wearable Corpus CC0-1.0 Prior Art · Mukkamala et al. (2015) — 'Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice' (2015-08, Ramakrishna Mukkamala et al., academic, other, IP: public-domain)] Canonical 2015 review of cuffless blood-pressure estimation by pulse transit time / pulse arrival time / pulse wave velocity: the physiological models, the practical sensor configurations (ECG+PPG, dual PPG, ballistocardiogram+PPG), the calibration strategies, and the accuracy limitations. Prior art for cuffless-BP wearable claims reciting any of the configurations or calibration approaches surveyed here — they were collected, modeled, and published by 2015. Combined with watch/ring/patch form-factor disclosures, makes wearable PTT-based BP an obvious combination under [[obviousness-template]]. Disclosed wearable sensors & endpoints: sensor-ecg, sensor-ppg, sensor-cuffless-bp-ptt, sensor-cuffless-bp-tonometry, algo-pwv-bp-estimation, blood-pressure, arterial-stiffness. CPC: A61B 5/02125, A61B 5/021, A61B 5/0285.
“Mukkamala R, Hahn J-O, Inan OT, Mestha LK, Kim C-S, Töreyin H, Kyal S. 'Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.' IEEE Transactions on Biomedical Engineering 2015;62(8):1879-1901. — Canonical 2015 review of cuffless blood-pressure estimation by pulse transit time / pulse arrival time / pulse wave velocity: the physiological model…”
written · p. 175 · 2015-08-01 · open
Samsung Electronics Co., Ltd. · free_wearable_corpus · en
4[Free Wearable Corpus CC0-1.0 Prior Art · Samsung Galaxy Watch3 / Samsung Health Monitor (2020) — wrist single-lead ECG and optical-PPG cuffless blood pressure (2020-08, Samsung Electronics Co., Ltd., private, watch, IP: patented)] Discloses a wristworn device that takes a single-lead ECG with on-device AF classification and, separately, estimates blood pressure from the wrist optical-PPG pulse waveform after calibration against a periodic conventional cuff measurement (a calibrated-cuffless approach). Anticipates wrist-cuffless-BP claims reciting 'estimating blood pressure from a wrist photoplethysmography signal calibrated by a reference cuff reading' from 2020 — the underlying PTT/PWV-BP technique is much older ([[geddes-1981-pulse-transit-time-bp]], [[mukkamala-2015-ptt-cuffless-bp-review]]). Product-side anchor for the watch × cuffless-BP cross-cut. Disclosed wearable sensors & endpoints: sensor-ecg, sensor-ppg, sensor-cuffless-bp-ptt, algo-afib-detection, algo-arrhythmia-classification, algo-pwv-bp-estimation, algo-hr, electrocardiogram, atrial-fibrillation, blood-pressure. CPC: A61B 5/318, A61B 5/02125, A61B 5/021, A61B 5/352.
“Samsung Electronics. 'Samsung Health Monitor' app on Galaxy Watch3 / Watch Active2, 2020 — wrist single-lead ECG (between a back-crystal electrode and a side-button electrode touched by the opposite hand, with AF/sinus classification) and a cuffless blood-pressure feature using the optical (PPG) pulse-wave signal calibrated against a periodic conventional cuff reading. (Cleare…”
written · p. 193 · 2020-08-01 · open