← concepts · the commons
sensor-ph
3 moment(s) that assert this concept — showing 1–3 of 3
strong3 independent sources
↣ how this spread over time →reuse terms across this evidence: 3 openly licensed
scholarly papers (1)
Amay J. Bandodkar / Joseph Wang (UC San Diego) · free_wearable_corpus · en
1[Free Wearable Corpus CC0-1.0 Prior Art · Bandodkar & Wang (2014) — 'Non-invasive wearable electrochemical sensors: a review' (2014-07, Amay J. Bandodkar / Joseph Wang (UC San Diego), academic, other, IP: public-domain)] Surveys, as of 2014, wearable non-invasive electrochemical biosensors across body fluids and form factors — temporary-tattoo electrodes on the skin (sweat lactate, Na+, ammonium, pH), textile-integrated sensors, mouthguard (saliva) sensors, contact-lens (tear glucose) sensors, and the transdermal/interstitial route — including the sampling, transduction, and on-body electronics issues. Prior art for wearable-electrochemical-sensing claims reciting any of the analyte/form-factor combinations collected here; the approaches were published by 2014. General anchor for the electrochemical wearable cross-cuts. Disclosed wearable sensors & endpoints: sensor-lactate, sensor-electrolyte, sensor-ph, sensor-glucose-cgm, sensor-alcohol-transdermal, sensor-uric-acid, sensor-cortisol, algo-electrolyte-trend, algo-hydration-status, sweat-analytes. CPC: A61B 5/1468, A61B 5/14546, A61B 5/14507, G01N 27/327.
“Bandodkar AJ, Wang J. 'Non-invasive wearable electrochemical sensors: a review.' Trends in Biotechnology 2014;32(7):363-371. — Surveys, as of 2014, wearable non-invasive electrochemical biosensors across body fluids and form factors — temporary-tattoo electrodes on the skin (sweat lactate, Na+, ammonium, pH), textile-integrated sensors, mouthguard (saliva) sensors, contact-len…”
written · p. 179 · 2014-07-01 · open
Wei Gao et al. / Ali Javey group (UC Berkeley) · free_wearable_corpus · en
2[Free Wearable Corpus CC0-1.0 Prior Art · Gao et al. (Javey group) (2016) — fully integrated wearable sensor array for multiplexed in-situ perspiration analysis (2016-01-28, Wei Gao et al. / Ali Javey group (UC Berkeley), academic, headband, IP: public-domain)] Discloses a fully integrated wearable (wristband / headband) with an array of electrochemical sensors measuring multiple sweat analytes simultaneously (glucose, lactate, Na+, K+) plus skin temperature for real-time signal compensation, with on-board signal conditioning, microcontroller, and wireless transmission to a phone — i.e. a complete in-situ sweat biochemistry monitor. Any wearable claim reciting 'a band-form device with an array of two or more electrochemical sweat-analyte sensors plus a temperature sensor for compensation, with integrated electronics and wireless output' reads on Gao/Javey 2016. Anchor for the sweat-electrochemical-sensing cross-cuts on the real side; [[bandodkar-wang-2014-wearable-electrochemical-sensors-review]] is the contemporaneous review. Disclosed wearable sensors & endpoints: sensor-lactate, sensor-glucose-cgm, sensor-electrolyte, sensor-ph, sensor-skin-temperature, sensor-microfluidic-sweat-collection, algo-electrolyte-trend, algo-hydration-status, sweat-glucose, sweat-lactate. CPC: A61B 5/14546, A61B 5/1468, A61B 5/4266, G01N 27/327.
“Gao W, Emaminejad S, Nyein HYY, Challa S, Chen K, Peck A, et al. (Javey A). 'Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis.' Nature 2016;529(7587):509-514. — Discloses a fully integrated wearable (wristband / headband) with an array of electrochemical sensors measuring multiple sweat analytes simultaneously (glucose, lactate, Na+, K+) pl…”
written · p. 178 · 2016-01-28 · open
Ahyeon Koh et al. / John A. Rogers group (Northwestern) · free_wearable_corpus · en
3[Free Wearable Corpus CC0-1.0 Prior Art · Koh et al. (Rogers group) (2016) — soft wearable microfluidic device for sweat capture, storage, and colorimetric sensing (2016-11-23, Ahyeon Koh et al. / John A. Rogers group (Northwestern), academic, patch, IP: public-domain)] Discloses a soft, skin-mounted microfluidic 'sticker' that wicks sweat from the skin into a network of microchannels and reservoirs, measures sweat rate and total sweat loss, and performs colorimetric assays (pH, chloride, lactate, glucose) read out by eye or smartphone camera. Any wearable claim reciting 'a skin-mounted patch with microfluidic channels collecting perspiration' combined with 'rate measurement' and/or 'colorimetric or electrochemical analysis of constituents' reads on Koh/Rogers 2016. Anchor for the patch × microfluidic-sweat-collection cross-cut on the real side; [[dune-stillsuit]] (1965) is the fictional antecedent. Disclosed wearable sensors & endpoints: sensor-microfluidic-sweat-collection, sensor-sweat-rate, sensor-ph, sensor-lactate, sensor-electrolyte, sensor-glucose-cgm, algo-hydration-status, algo-electrolyte-trend, sweat-rate, sweat-pH. CPC: A61B 10/0064, A61B 5/4266, B01L 3/502707, A61B 5/1486.
“Koh A, Kang D, Xue Y, Lee S, Pielak RM, Kim J, et al. (Rogers JA). 'A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat.' Science Translational Medicine 2016;8(366):366ra165. — Discloses a soft, skin-mounted microfluidic 'sticker' that wicks sweat from the skin into a network of microchannels and reservoirs, measures sweat rate and…”
written · p. 177 · 2016-11-23 · open