← concepts · the commons
valve-capillary-stop
36 moment(s) that assert this concept — showing 1–36 of 36
moderateTwo independent sources — corroborated, but not broadly
↣ how this spread over time →reuse terms across this evidence: 36 openly licensed
scholarly papers (3)
Lorand Eoetvoes (1886); Wilfrid Noel Bond (1928 dimensionless form) · openie_prior_art · en
1Bond / Eoetvoes Number Bo = rho g L^2 / gamma (Lorand Eoetvoes (1886); Wilfrid Noel Bond (1928 dimensionless form), 1886): Bond number explains why microfluidics works at all: at L ~ 100 microns, Bo ~ 10^-3 for water, so gravity is irrelevant and surface tension dominates. This is THE physical foundation for the microfluidic regime; anchors every patent claim that recites 'gravity-independent operation', 'orientation-independent chip', or 'surface-tension-driven liquid handli
“Eoetvoes, R. Ann. Phys. 263, 448 (1886)”
written · p. 1 · 1886-01-01 · open
Daniel Bonn; Jens Eggers; Joseph Indekeu; Jacques Meunier; Etienne Rolley · openie_prior_art · en
2Bonn et al. 2009 - Wetting and spreading (Rev. Mod. Phys. 81, 739) (Daniel Bonn; Jens Eggers; Joseph Indekeu; Jacques Meunier; Etienne Rolley, 2009): Bonn et al. 2009 is the canonical Reviews of Modern Physics article on wetting and spreading. Anticipates dynamic-wetting microfluidic claims, contact-line-pinning-based valves, contact-angle-hysteresis-driven flow rectifiers. Any patent asserting novelty around 'novel wetting dynamics' in microfluidics is anticipated by this re
“Rev. Mod. Phys. 81, 739 (2009)”
written · p. 1 · 2009-01-01 · open
Pierre-Gilles de Gennes · openie_prior_art · en
3de Gennes 1985 - Wetting: statics and dynamics (Rev. Mod. Phys. 57, 827) (Pierre-Gilles de Gennes, 1985): de Gennes 1985 is the foundational modern review of wetting theory, predating Bonn 2009 by two decades. Documents contact-line motion at finite Ca, precursor films, contact-angle hysteresis, and partial-wetting equilibrium. Anticipates microfluidic claims on dynamic contact-line behavior, droplet-edge motion on patterned surfaces, and capillary-driven flow with viscous di
“Rev. Mod. Phys. 57, 827 (1985)”
written · p. 1 · 1985-01-01 · open
Pierre-Gilles de Gennes; Francoise Brochard-Wyart; David Quere · openie_prior_art · en
4de Gennes, Brochard-Wyart & Quere 2004 - Capillarity and Wetting Phenomena (Pierre-Gilles de Gennes; Francoise Brochard-Wyart; David Quere, 2004): The definitive modern textbook on capillarity and wetting, by three Nobel-class authors. Anticipates microfluidic claims involving contact-line dynamics in microchannels, wetting of patterned surfaces, droplet spreading and pinning, superhydrophobic-surface microfluidics, capillary-pumping designs, and electrowetting at the Young/L
“de Gennes, Brochard-Wyart, Quere 'Capillarity and Wetting Phenomena' Springer (2004)”
written · p. 1 · 2004-01-01 · open
Multiple academic groups (KAIST, Madou-derived centrifugal microfluidics community) · openie_prior_art · en
5Centrifugal Lab-on-a-Disc for Salivary Caries-Risk Biomarker Detection (Multiple academic groups (KAIST, Madou-derived centrifugal microfluidics community), 2018): Discloses a centrifugal lab-on-a-disc dedicated to caries-risk assessment from raw saliva, combining bacterial enumeration with biochemical assays on a single injection-molded disc. Builds on Madou centrifugal microfluidics architecture (entry: madou-2006-centrifugal-microfluidics). Anticipates: dental-chairside CD
“Park et al. Sens Act B 2018 doi:10.1016/j.snb.2018.04.114”
written · p. 1 · 2018-01-01 · open
Madou group, UC Irvine (and earlier Burstein/Tecan) · openie_prior_art · en
6Lab-on-a-CD: centrifugal microfluidics platform (Madou group, UC Irvine (and earlier Burstein/Tecan), 2006): Comprehensive review and synthesis of centrifugal microfluidics: pumping by spin-rate-controlled centrifugal force, valving by capillary-burst pressure thresholds, mixing by Coriolis-aided shaking, and assay sequencing by sequential burst-frequency design. Anticipates: lab-on-disc architecture, capillary-burst valves with threshold rotational frequencies, pumping-as-ro
“Annu. Rev. Biomed. Eng. 2006, 8, 601–628”
written · p. 1 · 2006-01-01 · open
Oh, Ahn (SUNY Buffalo / Cincinnati) · openie_prior_art · en
7Thermoresponsive hydrogel microvalves (Oh, Ahn (SUNY Buffalo / Cincinnati), 2006): Comprehensive review of microvalves enumerating active (pneumatic, thermal, electrostatic, electromagnetic, piezoelectric, electrochemical, electrowetting) and passive (check, capillary-burst, hydrophobic) categories. Methodologically essential as the unified reference for microvalve prior art across the entire field; useful for invalidity contention against any patent claiming a 'novel microva
“J. Micromech. Microeng. 2006, 16, R13–R39”
written · p. 1 · 2006-01-01 · open
David Quere · openie_prior_art · en
8Quere 2008 - Wetting and roughness (Annu. Rev. Mater. Res. 38, 71) (David Quere, 2008): Quere 2008 is the canonical review of wetting on rough/structured surfaces, covering the Wenzel (homogeneous wetting) and Cassie-Baxter (composite air-pocket wetting) states and the pinning transitions between them. Anticipates microfluidic claims involving superhydrophobic-textured channels for slip enhancement, liquid-infused surfaces (SLIPS analog) for fouling resistance, directional dr
“Annu. Rev. Mater. Res. 38, 71 (2008)”
written · p. 1 · 2008-01-01 · open
Thomas Young · openie_prior_art · en
9Young 1805 — An Essay on the Cohesion of Fluids (Thomas Young, 1805-12-20): Discloses the fundamental force balance at the three-phase (solid-liquid-vapor) contact line and defines the equilibrium contact angle in terms of the three interfacial tensions. This Young equation is the load-bearing relation for: (a) capillary-driven priming of microfluidic channels (paper microfluidics, lateral-flow assays, capillary stop valves); (b) all surface-treatment patents that claim a con
“Phil. Trans. R. Soc. 95, 65-87 (1805)”
written · p. 1 · 1805-01-01 · open
Thomas Young; Pierre-Simon Laplace · openie_prior_art · en
10Young-Laplace Equation (combined 1805-1806) (Thomas Young; Pierre-Simon Laplace, 1806): Combined Young-Laplace equation is the single most invoked classical result in microfluidic device design: every droplet generator, every capillary-driven assay, every paper-microfluidic device, and every surface-energy patterned channel inherits its quantitative behavior from this equation. As a unified prior-art anchor, the combined equation invalidates broad patents claiming 'surface-te
“Phil. Trans. R. Soc. 95, 65-87 (1805)”
written · p. 1 · 1806-01-01 · open
Abaxis (Zoetis) · openie_prior_art · en
11Abaxis VetScan VS2 veterinary clinical chemistry analyzer (Abaxis (Zoetis)): Abaxis VetScan VS2 veterinary clinical chemistry analyzer [Subsystems: pump-centrifugal-rotational, valve-capillary-stop, fabrication-thermoplastic-injection-molding; CPC: B01L 3/00, G01N 35/00]
“Abaxis (acquired by Zoetis 2018) VetScan VS2 system; same disc-format as Piccolo Xpress for veterinary use.”
written · p. 1 · 2026-05-01 · open
Abaxis (acquired by Zoetis, then Abbott) · openie_prior_art · en
12Abbott Piccolo Xpress / Abaxis disc-format clinical chemistry analyzer (Abaxis (acquired by Zoetis, then Abbott)): Abbott Piccolo Xpress / Abaxis disc-format clinical chemistry analyzer [Subsystems: pump-centrifugal-rotational, valve-capillary-stop, fabrication-thermoplastic-injection-molding; CPC: B01L 3/00, G01N 35/00]
“Abbott Piccolo Xpress (originally Abaxis). https://www.abbott.com”
written · p. 1 · 2026-05-01 · open
Aquesys Inc. / Allergan / AbbVie · openie_prior_art · en
13XEN Gel Stent (Allergan / AbbVie) (Aquesys Inc. / Allergan / AbbVie): XEN Gel Stent (Allergan / AbbVie) [Subsystems: valve-capillary-stop; CPC: A61F 9/00781]
“Sheybani A et al. Fluid dynamics of a novel micro-fistula implant for the surgical treatment of glaucoma. Invest Ophthalmol Vis Sci 2015; FDA clearance 2016.”
written · p. 1 · 2026-05-01 · open
AIM Biotech Pte. Ltd. (MIT Kamm / NUS spinout, Singapore) · openie_prior_art · en
14AIM Biotech idenTx 3D Cell-Culture Microfluidic Chip (AIM Biotech Pte. Ltd. (MIT Kamm / NUS spinout, Singapore)): AIM Biotech idenTx 3D Cell-Culture Microfluidic Chip [Subsystems: architecture-organ-on-chip-vasculature, valve-capillary-stop, cell-organoid-perfusion; CPC: C12M 23/16, C12M 29/10]
“Shin Y, Han S, Jeon JS, Yamamoto K, Zervantonakis IK, Sudo R, Kamm RD, Chung S. Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels. Nat Protoc 2012; AIM Biotech founded 2012 from MIT Roger Kam”
written · p. 1 · 2026-05-01 · open
ASML Holding N.V. · openie_prior_art · en
15ASML TWINSCAN immersion lithography water-handling hood (ASML Holding N.V.): ASML TWINSCAN immersion lithography water-handling hood [Subsystems: valve-capillary-stop, pump-pressure-controlled-air-over-liquid, interface-pressure-manifold, thermal-on-chip-resistive-heater, surface-superhydrophobic-patterning; CPC: G03F 7/70341, G03F 7/2041, B01L 3/00, B08B 3/04]
“US20040263808A1 / US7193232B2 Lithographic apparatus and device manufacturing method (ASML, immersion lithography liquid supply system); see also Owa & Nagasaka, Immersion lithography: its potential performance and issues, SPIE 2003.”
written · p. 1 · 2026-05-01 · open
Lorand Eoetvoes (1886); Wilfrid Noel Bond (1928 dimensionless form) · openie_prior_art · en
16Bond / Eoetvoes Number Bo = rho g L^2 / gamma (Lorand Eoetvoes (1886); Wilfrid Noel Bond (1928 dimensionless form)): Bond / Eoetvoes Number Bo = rho g L^2 / gamma [Subsystems: pump-capillary-passive, valve-capillary-stop; CPC: B01L 3/502]
“Eoetvoes, R. (1886). 'Ueber den Zusammenhang der Oberflaechenspannung der Fluessigkeiten mit ihrem Molekularvolumen.' Annalen der Physik 263(3): 448-459. doi:10.1002/andp.18862630309. Bond, W. N. (1928). Proc. Phys. Soc. 41, 1.”
written · p. 1 · 2026-05-01 · open
Daniel Bonn; Jens Eggers; Joseph Indekeu; Jacques Meunier; Etienne Rolley · openie_prior_art · en
17Bonn et al. 2009 - Wetting and spreading (Rev. Mod. Phys. 81, 739) (Daniel Bonn; Jens Eggers; Joseph Indekeu; Jacques Meunier; Etienne Rolley): Bonn et al. 2009 - Wetting and spreading (Rev. Mod. Phys. 81, 739) [Subsystems: surface-hydrophilic-treatment, surface-superhydrophobic-patterning, valve-capillary-stop, pump-capillary-passive; CPC: B01L 3/502]
“Bonn, D., Eggers, J., Indekeu, J., Meunier, J., Rolley, E. (2009). 'Wetting and spreading.' Rev. Mod. Phys. 81(2): 739-805. doi:10.1103/RevModPhys.81.739”
written · p. 1 · 2009-01-01 · open
Robert Bosch GmbH (LSU/LSF), NGK Spark Plug / NTK, Denso, Continental · openie_prior_art · en
18Zirconia ceramic lambda / NOx automotive exhaust sensor (Bosch LSU, NGK / NTK class) (Robert Bosch GmbH (LSU/LSF), NGK Spark Plug / NTK, Denso, Continental): Zirconia ceramic lambda / NOx automotive exhaust sensor (Bosch LSU, NGK / NTK class) [Subsystems: detection-electrochemical-on-chip, valve-capillary-stop, thermal-on-chip-resistive-heater, interface-electrode-integration, architecture-process-analytical-technology; CPC: G01N 27/4071, G01N 27/4075, G01N 27/419, G01N 33/00
“US5616825A Exhaust gas sensor and a process for producing the same (NGK Spark Plug); see also US5288374A (Bosch) limiting-current oxygen sensor and Riegel, Neumann & Wiedenmann, Exhaust gas sensors for automotive emission control, Solid Sta”
written · p. 1 · 2026-05-01 · open
Capitainer AB (KTH Royal Institute of Technology spinout, Niclas Roxhed group) · openie_prior_art · en
19Capitainer qDBS Quantitative Dried Blood Spot Microfluidic Card (Capitainer AB (KTH Royal Institute of Technology spinout, Niclas Roxhed group)): Capitainer qDBS Quantitative Dried Blood Spot Microfluidic Card [Subsystems: pump-capillary-passive, valve-capillary-stop, architecture-stat-test-cartridge; CPC: A61B 5/15]
“Lenk G, Sandkvist S, Pohanka A, Stemme G, Beck O, Roxhed N. A disposable sampling device to collect volume-measured DBS directly from a fingerprick onto DBS paper. Bioanalysis 2015; Capitainer AB founded 2014 (KTH spinout).”
written · p. 1 · 2026-05-01 · open
Pierre-Gilles de Gennes · openie_prior_art · en
20de Gennes 1985 - Wetting: statics and dynamics (Rev. Mod. Phys. 57, 827) (Pierre-Gilles de Gennes): de Gennes 1985 - Wetting: statics and dynamics (Rev. Mod. Phys. 57, 827) [Subsystems: surface-hydrophilic-treatment, surface-superhydrophobic-patterning, valve-capillary-stop, pump-capillary-passive, valve-electrowetting; CPC: B01L 3/502]
“de Gennes, P.-G. (1985). 'Wetting: statics and dynamics.' Rev. Mod. Phys. 57(3): 827-863. doi:10.1103/RevModPhys.57.827”
written · p. 1 · 1985-01-01 · open
Pierre-Gilles de Gennes; Francoise Brochard-Wyart; David Quere · openie_prior_art · en
21de Gennes, Brochard-Wyart & Quere 2004 - Capillarity and Wetting Phenomena (Pierre-Gilles de Gennes; Francoise Brochard-Wyart; David Quere): de Gennes, Brochard-Wyart & Quere 2004 - Capillarity and Wetting Phenomena [Subsystems: surface-hydrophilic-treatment, surface-superhydrophobic-patterning, valve-capillary-stop, pump-capillary-passive, valve-electrowetting; CPC: B01L 3/502, B01L 3/5027]
“de Gennes, P.-G., Brochard-Wyart, F., Quere, D. (2004). 'Capillarity and Wetting Phenomena: Drops, Bubbles, Pearls, Waves.' Springer-Verlag, New York. ISBN 978-0-387-00592-1.”
written · p. 1 · 2004-01-01 · open
Glaukos Corporation · openie_prior_art · en
22Glaukos iStent Trabecular Micro-Bypass Stent (Glaukos Corporation): Glaukos iStent Trabecular Micro-Bypass Stent [Subsystems: interface-o-ring-seal, valve-capillary-stop; CPC: A61F 9/00781, A61F 9/00772]
“Spiegel D, Kobuch K. Trabecular meshwork bypass tube shunt: initial case series. Adv Ther 2007; Glaukos FDA PMA P080030 (2012).”
written · p. 1 · 2026-05-01 · open
Gyros AB (Sweden) · openie_prior_art · en
23Gyros Bioaffy CD immunoassay platform (Gyros AB (Sweden)): Gyros Bioaffy CD immunoassay platform [Subsystems: pump-centrifugal-rotational, valve-capillary-stop, valve-burst-frangible, separation-affinity-capture, fabrication-thermoplastic-injection-molding; CPC: B01L 3/00, G01N 33/53]
“Gyros (now Gyros Protein Technologies) Bioaffy / Gyrolab system. https://www.gyrosproteintechnologies.com”
written · p. 1 · 2026-05-01 · open
Ivantis Inc. (acquired by Alcon) · openie_prior_art · en
24Hydrus Microstent (Ivantis / Alcon) (Ivantis Inc. (acquired by Alcon)): Hydrus Microstent (Ivantis / Alcon) [Subsystems: valve-capillary-stop; CPC: A61F 9/00781]
“Camras LJ et al. A novel Schlemms canal scaffold. Invest Ophthalmol Vis Sci 2012; FDA PMA P170034 (2018).”
written · p. 1 · 2026-05-01 · open
Multiple academic groups (KAIST, Madou-derived centrifugal microfluidics community) · openie_prior_art · en
25Centrifugal Lab-on-a-Disc for Salivary Caries-Risk Biomarker Detection (Multiple academic groups (KAIST, Madou-derived centrifugal microfluidics community)): Centrifugal Lab-on-a-Disc for Salivary Caries-Risk Biomarker Detection [Subsystems: pump-centrifugal-rotational, valve-burst-frangible, valve-capillary-stop, architecture-multiplex-cartridge; CPC: B01L 3/5027, G01N 33/487]
“Park J et al., Sensors and Actuators B: Chemical 268:218-226 (2018); doi:10.1016/j.snb.2018.04.114”
written · p. 1 · 2026-05-01 · open
Madou group, UC Irvine (and earlier Burstein/Tecan) · openie_prior_art · en
26Lab-on-a-CD: centrifugal microfluidics platform (Madou group, UC Irvine (and earlier Burstein/Tecan)): Lab-on-a-CD: centrifugal microfluidics platform [Subsystems: pump-centrifugal-rotational, valve-burst-frangible, valve-capillary-stop, fabrication-thermoplastic-injection-molding; CPC: B01L 3/00, G01N 35/00]
“Madou, M.; Zoval, J.; Jia, G.; Kido, H.; Kim, J.; Kim, N. Lab on a CD. Annu. Rev. Biomed. Eng. 2006, 8, 601–628. DOI: 10.1146/annurev.bioeng.8.061505.095758”
written · p. 1 · 2026-05-01 · open
MIMETAS BV (Leiden University / Paul Vulto, Thomas Hankemeier) · openie_prior_art · en
27MIMETAS OrganoPlate 3-Lane / OrganoPlate Graft Microfluidic Plate (MIMETAS BV (Leiden University / Paul Vulto, Thomas Hankemeier)): MIMETAS OrganoPlate 3-Lane / OrganoPlate Graft Microfluidic Plate [Subsystems: architecture-organ-on-chip-vasculature, valve-capillary-stop, cell-organoid-perfusion, fabrication-thermoplastic-injection-molding; CPC: C12M 23/12, C12M 23/16, C12M 29/10]
“Trietsch SJ, Israels GD, Joore J, Hankemeier T, Vulto P. Microfluidic titer plate for stratified 3D cell culture. Lab Chip 2013; MIMETAS BV founded 2013 from Leiden University.”
written · p. 1 · 2026-05-01 · open
Oh, Ahn (SUNY Buffalo / Cincinnati) · openie_prior_art · en
28Thermoresponsive hydrogel microvalves (Oh, Ahn (SUNY Buffalo / Cincinnati)): Thermoresponsive hydrogel microvalves [Subsystems: valve-thermal-paraffin, valve-burst-frangible, valve-capillary-stop; CPC: F16K 99/00]
“Oh, K. W.; Ahn, C. H. A review of microvalves. J. Micromech. Microeng. 2006, 16, R13–R39. DOI: 10.1088/0960-1317/16/5/R01”
written · p. 1 · 2026-05-01 · open
3M (Organic Vapor Monitor), SKC Inc. (UMEx/575 series), Assay Technology, Gradko, Radiello (Sigma-Aldrich) · openie_prior_art · en
29Passive-diffusion organic-vapor dosimeter badge (SKC / Assay Technology / 3M class) (3M (Organic Vapor Monitor), SKC Inc. (UMEx/575 series), Assay Technology, Gradko, Radiello (Sigma-Aldrich)): Passive-diffusion organic-vapor dosimeter badge (SKC / Assay Technology / 3M class) [Subsystems: valve-capillary-stop, surface-functionalization-silane, interface-o-ring-seal, architecture-stat-test-cartridge; CPC: G01N 1/2214, G01N 33/0009, G01N 1/22, A61B 5/097]
“US3992156A Diffusional dosimeter (Donald W. Underhill / 3M-style passive diffusion sampler), 1976; see also Palmes & Gunnison, Personal monitoring device for gaseous contaminants, Am. Ind. Hyg. Assoc. J. 34, 78 (1973).”
written · p. 1 · 2026-05-01 · open
David Quere · openie_prior_art · en
30Quere 2008 - Wetting and roughness (Annu. Rev. Mater. Res. 38, 71) (David Quere): Quere 2008 - Wetting and roughness (Annu. Rev. Mater. Res. 38, 71) [Subsystems: surface-superhydrophobic-patterning, surface-hydrophilic-treatment, valve-capillary-stop; CPC: B01L 3/502, B01L 3/5027]
“Quere, D. (2008). 'Wetting and roughness.' Annu. Rev. Mater. Res. 38: 71-99. doi:10.1146/annurev.matsci.38.060407.132434”
written · p. 1 · 2008-01-01 · open
InnFocus Inc. (Santen Pharmaceutical) · openie_prior_art · en
31PreserFlo MicroShunt (Santen / InnFocus) (InnFocus Inc. (Santen Pharmaceutical)): PreserFlo MicroShunt (Santen / InnFocus) [Subsystems: valve-capillary-stop; CPC: A61F 9/00781]
“Pinchuk L et al. The use of poly(styrene-block-isobutylene-block-styrene) as a microshunt to treat glaucoma. Regen Biomater 2016.”
written · p. 1 · 2026-05-01 · open
Sherlock Biosciences Inc. · openie_prior_art · en
32Sherlock Biosciences SHERLOCK Cartridge (Sherlock Biosciences Inc.): Sherlock Biosciences SHERLOCK Cartridge [Subsystems: pump-capillary-passive, valve-burst-frangible, valve-capillary-stop, thermal-isothermal-amplification, interface-blister-pack-reagent-storage, detection-fluorescence-on-chip; CPC: C12Q 1/6883, B01L 3/502]
“Sherlock Biosciences press release 2024-04 SHERLOCK STI; FDA Breakthrough Designation 2023-12-14; US10266887B2 (Cas13a-based detection)”
written · p. 1 · 2026-05-01 · open
Burstein Technology (acquired by Tecan) · openie_prior_art · en
33Burstein/Tecan LabCD original disc-format platform (Burstein Technology (acquired by Tecan)): Burstein/Tecan LabCD original disc-format platform [Subsystems: pump-centrifugal-rotational, valve-capillary-stop, fabrication-thermoplastic-injection-molding; CPC: B01L 3/00, G01N 35/00]
“Burstein Technology / Tecan LabCD platform. https://www.tecan.com (LabCD acquired and integrated)”
written · p. 1 · 2026-05-01 · open
Thomas Young · openie_prior_art · en
34Young 1805 — An Essay on the Cohesion of Fluids (Thomas Young): Young 1805 — An Essay on the Cohesion of Fluids [Subsystems: surface-hydrophilic-treatment, surface-superhydrophobic-patterning, valve-capillary-stop, pump-capillary-passive; CPC: B01L 3/00, B01L 3/502, G01N 13/00]
“Young, T. (1805). 'An essay on the cohesion of fluids.' Philosophical Transactions of the Royal Society of London 95: 65-87. doi:10.1098/rstl.1805.0005”
written · p. 1 · 1805-01-01 · open
Thomas Young; Pierre-Simon Laplace · openie_prior_art · en
35Young-Laplace Equation (combined 1805-1806) (Thomas Young; Pierre-Simon Laplace): Young-Laplace Equation (combined 1805-1806) [Subsystems: pump-capillary-passive, valve-capillary-stop, droplet-t-junction-generation, droplet-flow-focusing-generation, droplet-step-emulsification; CPC: B01L 3/00, B01L 3/502, B01F 33/30]
“Young, T. Phil. Trans. R. Soc. 95, 65-87 (1805); Laplace, P. S. Mecanique Celeste, Supplement to Book X (1806). Combined as DeltaP = gamma(1/R1 + 1/R2) with boundary condition cos(theta) at three-phase line.”
written · p. 1 · 1805-01-01 · open
OpenIE Microfluidics Commons · openie_microfluidics_cad · en
36Centrifugal lab-on-disc reference (CD-format): 120 mm diameter PMMA disc with 4 parallel assay paths radiating from central sample-application well at 5 mm radius. Each path: sample chamber → metering chamber → reagent chamber 1 (burst at 12 Hz) → mixing chamber → reagent chamber 2 (burst at 20 Hz) → detection cell at 35 mm radius. Channel widths 200–500 µm, depths 100–300 µm.
“120 mm diameter PMMA disc with 4 parallel assay paths radiating from central sample-application well at 5 mm radius. Each path: sample chamber → metering chamber → reagent chamber 1 (burst at 12 Hz) → mixing chamber → reagent chamber 2 (bur”
written · p. 1 · 2026-05-09 · open