Encoding unit — one grounded idea

1 A 3D non-linear stick model of the LNG terminal is developed in ANSYS to evaluate the seismic response of structural components through non-linear analysis.
“Section 5 presents a 3D non-linear stick model of the LNG terminal, fully developed in the ANSYS environment (ANSYS, 2015). This FE global model allows for evaluation of the seismic response of structural components of the plant by means of a non-linear analysis presented in Section 6.”
written · p. 3 · 2017-10-16 · zh · Oreste S. Bursi · Probabilistic seismic analysis of an LNG subplant
id: 3700e6e32f3292c9

from the paper Probabilistic seismic analysis of an LNG subplant (2017)