Encoding unit — one grounded idea

1 The endplate potential amplitude is normalized to a resting membrane potential of -75 mV using the equation VNOR = [VOBS × (-75)] / RMP.
“EPP amplitudes were normalized to a membrane potential of -75 mV using the following equation VNOR = [VOBS x (-75)]/RMP, where VNOR indicates the corrected amplitude, VOBS the recorded amplitude and RMP the recorded resting membrane potential [19–21].”
written · p. 3 · 2013-09-05 · nl · Mariana C. Rocha · Early Changes of Neuromuscular Transmission in the SOD1(G93A) Mice Model of ALS …
id: daed94e3745965d1

from the paper Early Changes of Neuromuscular Transmission in the SOD1(G93A) Mice Model of ALS Start Long before Motor Symptoms Onset (2013)

concepts in this idea