Cross-Sectional SEM Metrology and Process Identification Benchmark for Bosch Deep Reactive-Ion Etching (DRIE) Recipe Transfer
🟢 Green Signal · Good Epistemic StandingCD₅ Disruption
+0.0000 · FWCI 0.00 · Root Independence 1.00 · Full Shepard Citator →Bryutkin, Andrey, Savinson, Benjamin
2026 · doi:10.5281/zenodo.24394216
Cross-sectional scanning electron microscope (SEM) metrology benchmark for process identification and cross-tool recipe transfer in deep reactive-ion etching (DRIE). Deep reactive-ion etching (DRIE) via the pulsed Bosch process (time-multiplexed alternating cycles of C4F8 fluorocarbon passivation and SF6 chemical/ion-assisted etching) is the primary fabrication technology for high-aspect-ratio silicon microstructures in micro-electro-mechanical systems (MEMS), through-silicon vias (TSV), and micro-optics. When transferring an established production recipe to an uncharacterized reactor (receiving tool), tool-to-tool hardware differences—including chamber seasoning, gas showerhead conductances, inductively coupled plasma (ICP) RF impedance matching, platen electrostatic chucking, and pumping speed—prevent direct recipe copying. Uncalibrated transfer produces severe profile deviations including sidewall bow, scallop roughness, footing, and loss of critical dimensions. This benchmark provides thirteen self-contained datasets representing distinct plasma etch reactors (1 public reference tool example, plus 12 receiving tool transfer cases case_00 through case_11). Each dataset contains: (1) cleaved silicon test structure cross-sections (calibration_sems) across 8–24 calibration runs under varied DC sheath self-bias voltages (30–110 V), chamber pressures (1–6 Pa), block timings, and layout contexts (0.4–1.0 um opening widths, 0.02–0.60 open area fractions); (2) cumulative etch cycles elapsed before wafer cleaving (1 to 24 cycles); (3) target production SEM micrographs (target_sems) etched on the qualified source tool across three production layouts; (4) nominal operating conditions and tolerance window half-widths; and (5) an undistorted reference frame (reference_sem) with lithographic alignment fiducials for electron-beam scan calibration. Micrographs are provided as 12-bit detector count arrays (384 x 256 pixels at 10.0 nm/pixel pitch) incorporating physical scan distortions (sub-pixel drift, magnification shift, scan shear) and secondary electron detector shot noise. Files included: bosch-drie-sem-benchmark.zip (complete dataset and documentation archive); README.md (comprehensive benchmark guide and quick-start loader); PHYSICS.md (plasma-surface reaction kinetics, Knudsen diffusion, and sheath dynamics); data_dictionary.csv (array shapes, physical units, and variable definitions); CITATION.cff (citation metadata); MD5SUMS.txt and SHA256SUMS.txt (cryptographic checksums). References:[1] F. Laermer, A. Schilp, US Patent 5,501,893 (1996).[2] H. Jansen et al., J. Micromech. Microeng. 5(2), 115–120 (1995). DOI: 10.1088/0960-1317/5/2/015.[3] A. A. Ayon et al., J. Electrochem. Soc. 146(1), 339–349 (1999). DOI: 10.1149/1.1391611.[4] B. Wu, A. Kumar, S. Pamarthy, J. Appl. Phys. 108(5), 051101 (2010). DOI: 10.1063/1.3474652.[5] J. W. Coburn, H. F. Winters, J. Appl. Phys. 50(5), 3189–3196 (1979). DOI: 10.1063/1.326355.[6] M. A. Blauw et al., J. Vac. Sci. Technol. B 18(6), 3453–3461 (2000). DOI: 10.1116/1.1319694.[7] C. K. Kang et al., J. Vac. Sci. Technol. B 19(4), 1388–1394 (2001). DOI: 10.1116/1.1387082.[8] M. J. de Boer et al., J. Microelectromech. Syst. 11(4), 385–401 (2002). DOI: 10.1109/JMEMS.2002.800939.[9] R. Dussart et al., J. Micromech. Microeng. 24(7), 073001 (2014). DOI: 10.1088/0960-1317/24/7/073001.[10] K. S. Chen et al., J. Microelectromech. Syst. 11(3), 264–275 (2002). DOI: 10.1109/JMEMS.2002.1007405.
cite & interoperate (Zotero / Alma / WorldCat ready)
Bryutkin, Andrey, Savinson, Benjamin. (2026). Cross-Sectional SEM Metrology and Process Identification Benchmark for Bosch Deep Reactive-Ion Etching (DRIE) Recipe Transfer. https://doi.org/10.5281/zenodo.24394216
@article{datacite105281zenodo2439,
title = {Cross-Sectional SEM Metrology and Process Identification Benchmark for Bosch Deep Reactive-Ion Etching (DRIE) Recipe Transfer},
author = {Bryutkin, Andrey and Savinson, Benjamin},
year = {2026},
doi = {10.5281/zenodo.24394216}
}
JSON · BibTeX · BibLaTeX · RIS (EndNote) · CSL-JSON · MARC21 XML · BIBFRAME 2.0 · citations JSON · CITO argument graph · IIIF v3 manifest · embed card