algo-arrhythmia-classification
9 moment(s) that assert this concept — showing 1–9 of 9
strong9 independent sources
↣ how this spread over time →reuse terms across this evidence: 9 openly licensed
scholarly papers (1)
AliveCor, Inc. (David Albert) · free_wearable_corpus · en
1[Free Wearable Corpus CC0-1.0 Prior Art · AliveCor Heart Monitor / KardiaMobile (2012) — smartphone-coupled single-lead ECG (2012-12, AliveCor, Inc. (David Albert), private, other, IP: patented)] Discloses a portable two-dry-electrode single-lead ECG recorder that the user contacts with the fingers (or chest) and that streams the trace to a smartphone for automated atrial-fibrillation detection — and, in the 2017 Kardia Band variant, the same dry-electrode single-lead ECG integrated into a wrist strap. Anticipates consumer single-lead-ECG and wrist-strap-ECG AF-detection claims from 2012/2017 — predating the Apple Watch Series 4 ECG (2018). Product-side anchor for the consumer-ECG cross-cut. Disclosed wearable sensors & endpoints: sensor-ecg, algo-afib-detection, algo-arrhythmia-classification, algo-hr, electrocardiogram, atrial-fibrillation, fingertip, chest, wrist. CPC: A61B 5/318, A61B 5/333, A61B 5/282, A61B 5/352.
“AliveCor, Inc. 'AliveCor Heart Monitor' (later 'KardiaMobile'), FDA-cleared December 2012 — a card-sized two-electrode module that records a single-lead ECG via dry electrodes touched by the fingers (or pressed to the chest) and streams it to a smartphone app for AF detection. (The 'Kardia Band' wrist-strap ECG accessory for Apple Watch followed in 2017, FDA cleared.) — Disclo…”
written · p. 162 · 2012-12-01 · open
Apple Inc. · free_wearable_corpus · en
2[Free Wearable Corpus CC0-1.0 Prior Art · Apple Watch Series 4 (2018) — wrist single-lead ECG and PPG-based irregular-rhythm notification (2018-09-12, Apple Inc., private, watch, IP: patented)] Discloses a wristworn device that records a single-lead ECG between a watch-back electrode and a crown electrode touched by the contralateral hand, classifies the rhythm (AF vs. sinus) on-device, and separately runs a PPG-based background algorithm flagging possible atrial fibrillation. Anticipates wristworn-ECG and watch-AF-detection claims postdating September 2018; the underlying single-lead ECG and PPG-rhythm-screening techniques are much older ([[einthoven-1903-string-galvanometer-ecg]], [[holter-1961-ambulatory-ecg]], [[allen-2007-ppg-review]], [[ieee-11073-10406-basic-ecg-2011]]). Product-side anchor for the watch × ECG and watch × PPG × AF-detection cross-cuts. Disclosed wearable sensors & endpoints: sensor-ecg, sensor-ppg, algo-afib-detection, algo-arrhythmia-classification, algo-hr, electrocardiogram, atrial-fibrillation, heart-rate, wrist, fingertip. CPC: A61B 5/318, A61B 5/333, A61B 5/352, A61B 5/02416.
“Apple Inc. 'Apple Watch Series 4', announced 12 September 2018 (ECG app and irregular rhythm notification feature enabled later in 2018) — a wristworn device taking a single-lead (Lead I) ECG between a back-crystal electrode and a Digital Crown electrode touched by the opposite hand, with on-device AF/sinus classification, plus a PPG-based irregular-rhythm (possible-AF) notifi…”
written · p. 161 · 2018-09-12 · open
U.S. Food and Drug Administration (CDRH); requester Apple Inc. · free_wearable_corpus · en
3[Free Wearable Corpus CC0-1.0 Prior Art · FDA De Novo DEN180044 (2018) — over-the-counter electrocardiograph software for use in detecting atrial fibrillation (Apple Watch ECG app) (2018-09-11, U.S. Food and Drug Administration (CDRH); requester Apple Inc., regulatory, watch, IP: regulatory-filing)] A public, dated FDA decision describing — and creating the device class for — over-the-counter single-lead ECG software on a consumer wrist-worn device with on-device AFib-vs-sinus classification. As a government disclosure it establishes, as of 11 September 2018, the public availability of the device described: a wristworn Lead-I ECG with consumer-facing rhythm classification. Useful prior art for later claims to that combination; the De Novo decision summary also enumerates the clinical validation and the bench/algorithm characteristics, which are themselves citable. Pairs with the product entry [[apple-watch-series4-ecg-2018]] and the standard [[ieee-11073-10406-basic-ecg-2011]]. Disclosed wearable sensors & endpoints: sensor-ecg, algo-afib-detection, algo-arrhythmia-classification, electrocardiogram, atrial-fibrillation, wrist, fingertip. CPC: A61B 5/318, A61B 5/352, A61B 5/333, G16H 50/20.
“U.S. FDA, De Novo Classification Request DEN180044 (Apple Inc., 'ECG App'), granted 11 September 2018 — decision summary at accessdata.fda.gov/cdrh_docs/reviews/DEN180044.pdf; established a new FDA device classification for over-the-counter electrocardiograph software intended to acquire, store, transfer and display a single-lead (Lead I) ECG and to provide a rhythm classifica…”
written · p. 202 · 2018-09-11 · open
U.S. Food and Drug Administration (CDRH); submitter iRhythm Technologies, Inc. · free_wearable_corpus · en
4[Free Wearable Corpus CC0-1.0 Prior Art · FDA 510(k) K113862 (~2011) — iRhythm Zio Patch, long-term single-lead adhesive ECG monitor (2011-12, U.S. Food and Drug Administration (CDRH); submitter iRhythm Technologies, Inc., regulatory, patch, IP: regulatory-filing)] A public, dated FDA record of a single-use adhesive chest patch that records one channel of ECG continuously for up to ~14 days for later arrhythmia analysis — the modern 'ECG patch' realization of ambulatory ECG ([[holter-1961-ambulatory-ecg]]). Establishes as of ~2011 the public availability of an adhesive long-wear single-lead ECG patch with downstream automated arrhythmia analysis; and, as a 510(k), it cites a predicate chain back to earlier ambulatory-ECG devices — that chain is itself prior art. Prior art for ECG-patch claims; product-side and regulatory anchor for the patch × ECG cross-cut. Cf. [[apple-watch-series4-ecg-2018]] (the wrist single-lead route). Disclosed wearable sensors & endpoints: sensor-ecg, algo-arrhythmia-classification, algo-afib-detection, electrocardiogram, arrhythmia, chest. CPC: A61B 5/333, A61B 5/282, A61B 5/0006, A61B 5/259.
“U.S. FDA, 510(k) Premarket Notification K113862 (iRhythm Technologies, Inc., 'Zio Patch') — record at accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K113862; a single-use adhesive chest patch recording a single channel of ECG continuously for up to ~14 days for later analysis, cleared as substantially equivalent to predicate ambulatory-ECG (Holter-class) devices. (Fol…”
written · p. 204 · 2011-12-01 · open
Norman J. Holter · free_wearable_corpus · en
5[Free Wearable Corpus CC0-1.0 Prior Art · Holter (1961) — continuous ambulatory electrocardiography (the Holter monitor) (1961-04-21, Norman J. Holter, academic, garment, IP: public-domain)] Establishes continuous, ambulatory, body-worn recording of the ECG over hours to days while the subject is active, for later analysis — the foundational 'wearable continuous ECG monitor'. Any claim reciting 'a body-worn device configured to continuously record an electrocardiographic signal of the wearer over an extended period for subsequent arrhythmia analysis' reads on Holter 1961. Anchor for the ambulatory-ECG / ECG-patch cross-cut; [[zio-patch-irhythm-2009]] and Apple Watch's ECG history both build on it. Disclosed wearable sensors & endpoints: sensor-ecg, algo-arrhythmia-classification, electrocardiogram, chest. CPC: A61B 5/333, A61B 5/282, A61B 5/0006.
“Holter NJ. 'New method for heart studies: continuous electrocardiography of active subjects over long periods is now practical.' Science 1961;134(3486):1214-1220. — Establishes continuous, ambulatory, body-worn recording of the ECG over hours to days while the subject is active, for later analysis — the foundational 'wearable continuous ECG monitor'. Any claim reciting 'a body…”
written · p. 140 · 1961-04-21 · open
IEEE / ISO/IEEE 11073 Personal Health Devices Working Group · free_wearable_corpus · en
6[Free Wearable Corpus CC0-1.0 Prior Art · IEEE Std 11073-10406-2011 — personal health device communication: basic electrocardiograph (1- to 3-lead ECG) (2011-12-30, IEEE / ISO/IEEE 11073 Personal Health Devices Working Group, standards, other, IP: standards)] A publicly-adopted standard defining the device model and data exchange for a personal/consumer 1-to-3-lead electrocardiograph — including reporting of the ECG waveform, derived heart rate, and rhythm/event annotations from a body-worn or handheld single-lead ECG device. Prior art for consumer-single-lead-ECG-wearable claims reciting the device model, lead configuration, or data fields standardized here (public from 2011, predating the Apple Watch / AliveCor consumer-ECG patent wave's later filings). Disclosed wearable sensors & endpoints: sensor-ecg, algo-hr, algo-arrhythmia-classification, electrocardiogram, heart-rate. CPC: A61B 5/318, A61B 5/333, G16H 40/63.
“IEEE Std 11073-10406-2011. 'Health informatics — Personal health device communication — Part 10406: Device specialization — Basic electrocardiograph (ECG) (1- to 3-lead ECG).' IEEE, 2011. — A publicly-adopted standard defining the device model and data exchange for a personal/consumer 1-to-3-lead electrocardiograph — including reporting of the ECG waveform, derived heart rate,…”
written · p. 154 · 2011-12-30 · open
Alexandros Pantelopoulos / Nikolaos G. Bourbakis · free_wearable_corpus · en
7[Free Wearable Corpus CC0-1.0 Prior Art · Pantelopoulos & Bourbakis (2010) — survey on wearable sensor-based systems for health monitoring and prognosis (2010-01, Alexandros Pantelopoulos / Nikolaos G. Bourbakis, academic, other, IP: public-domain)] Surveys, as of 2010, the architecture and components of wearable health-monitoring systems — sensors (ECG, PPG, SpO2, accelerometry, temperature, respiration), garment- and patch- and watch-based form factors, on-body processing, wireless body-area networking, and the analytics (arrhythmia, fall, activity, deterioration prediction). Prior art establishing that the general 'multi-sensor wearable + body-area network + cloud analytics' system architecture and its building blocks were collected and published by 2010 — useful against later claims to the bare system architecture. General anchor. Disclosed wearable sensors & endpoints: sensor-ecg, sensor-ppg, sensor-spo2, sensor-accelerometer, sensor-skin-temperature, sensor-respiration-impedance, algo-hr, algo-arrhythmia-classification, algo-spo2-estimation, algo-fall-detection. CPC: A61B 5/0006, A61B 5/00, G16H 40/67, H04W 84/18.
“Pantelopoulos A, Bourbakis NG. 'A survey on wearable sensor-based systems for health monitoring and prognosis.' IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) 2010;40(1):1-12. — Surveys, as of 2010, the architecture and components of wearable health-monitoring systems — sensors (ECG, PPG, SpO2, accelerometry, temperature, respiration), ga…”
written · p. 186 · 2010-01-01 · open
Polar Electro Oy · free_wearable_corpus · en
8[Free Wearable Corpus CC0-1.0 Prior Art · Polar H10 (2017) — research-grade chest-strap ECG heart-rate sensor (2017-01, Polar Electro Oy, private, garment, IP: patented)] Discloses a chest strap with two dry electrodes deriving single-lead ECG, with on-strap R-R-interval computation, multi-protocol broadcast (BLE + ANT+ + the 5 kHz GymLink legacy band), and accelerometer-assisted noise rejection. Anticipates chest-strap-ECG claims combining 'dry textile/elastic chest electrodes', 'on-strap derivation of R-R intervals and HR', and 'multi-protocol simultaneous wireless broadcast' from 2017. Product-side anchor for the garment/patch × ECG strap cross-cut; refines [[polar-sport-tester-pe2000-1982]]. Disclosed wearable sensors & endpoints: sensor-ecg, sensor-accelerometer, algo-hr, algo-hrv, algo-arrhythmia-classification, heart-rate, heart-rate-variability, r-r-interval, chest, sternum. CPC: A61B 5/0006, A61B 5/318, A61B 5/02438, H04W 4/80.
“Polar Electro Oy. 'Polar H10' chest heart-rate sensor, released 2017 — a chest strap with two dry electrodes deriving a single-lead ECG, computing R-R intervals and heart rate, with onboard 1-session memory, dual-broadcast (BLE + ANT+ + 5 kHz GymLink), an accelerometer (relative orientation), and well-documented R-R-interval accuracy (often used as a gold-standard reference fo…”
written · p. 212 · 2017-01-01 · open
Samsung Electronics Co., Ltd. · free_wearable_corpus · en
9[Free Wearable Corpus CC0-1.0 Prior Art · Samsung Galaxy Watch3 / Samsung Health Monitor (2020) — wrist single-lead ECG and optical-PPG cuffless blood pressure (2020-08, Samsung Electronics Co., Ltd., private, watch, IP: patented)] Discloses a wristworn device that takes a single-lead ECG with on-device AF classification and, separately, estimates blood pressure from the wrist optical-PPG pulse waveform after calibration against a periodic conventional cuff measurement (a calibrated-cuffless approach). Anticipates wrist-cuffless-BP claims reciting 'estimating blood pressure from a wrist photoplethysmography signal calibrated by a reference cuff reading' from 2020 — the underlying PTT/PWV-BP technique is much older ([[geddes-1981-pulse-transit-time-bp]], [[mukkamala-2015-ptt-cuffless-bp-review]]). Product-side anchor for the watch × cuffless-BP cross-cut. Disclosed wearable sensors & endpoints: sensor-ecg, sensor-ppg, sensor-cuffless-bp-ptt, algo-afib-detection, algo-arrhythmia-classification, algo-pwv-bp-estimation, algo-hr, electrocardiogram, atrial-fibrillation, blood-pressure. CPC: A61B 5/318, A61B 5/02125, A61B 5/021, A61B 5/352.
“Samsung Electronics. 'Samsung Health Monitor' app on Galaxy Watch3 / Watch Active2, 2020 — wrist single-lead ECG (between a back-crystal electrode and a side-button electrode touched by the opposite hand, with AF/sinus classification) and a cuffless blood-pressure feature using the optical (PPG) pulse-wave signal calibrated against a periodic conventional cuff reading. (Cleare…”
written · p. 193 · 2020-08-01 · open