← concepts · the commons
cell-trap-hydrodynamic
30 moment(s) that assert this concept — showing 1–30 of 30
moderateTwo independent sources — corroborated, but not broadly
↣ how this spread over time →reuse terms across this evidence: 30 openly licensed
scholarly papers (3)
Maurice Couette · openie_prior_art · en
1Couette 1890 — Concentric Cylinder Viscometer and Couette Flow (Maurice Couette, 1890): Discloses the canonical shear-driven flow geometry. Anchors: (a) all shear-controlled microfluidic devices including blood-cell deformability assays; (b) on-chip rheometry; (c) shear-stress-controlled cell-culture chips (vascular shear); (d) Taylor-Couette mixing reactors at small scale; (e) any flow chamber that imposes a controlled shear via a moving boundary. Anticipates patent claims r
“Ann. Chim. Phys. Ser. 6, 21, 433 (1890)”
written · p. 1 · 1890-01-01 · open
L. P. Lee, Di Carlo (UC Berkeley) · openie_prior_art · en
2Microfluidic cell-trap array for single-cell analysis (L. P. Lee, Di Carlo (UC Berkeley), 2006): Disclosed high-density hydrodynamic cell trap array: PDMS chip with serial-arranged U-shaped cup traps, each capturing exactly one cell from flowing suspension by streamline-following. Anticipates: U-cup hydrodynamic single-cell trap as a primitive, addressable single-cell observation arrays, and the architectural pattern subsequently elaborated by Tay-group and others for time-re
“Anal. Chem. 2006, 78, 4925–4930”
written · p. 1 · 2006-01-01 · open
Klavs F. Jensen and Peter K. Sorger groups, MIT · openie_prior_art · en
3El-Ali 2006 cells on chips (Klavs F. Jensen and Peter K. Sorger groups, MIT, 2006-07-27): The canonical Nature-insight review of cell biology on microfluidic chips: single-cell hydrodynamic and other trapping, perfusion culture with controlled microenvironments, microfluidic concentration-gradient generators, dynamic-stimulus delivery, on-chip lysis, and integration with downstream nucleic-acid/protein assays for systems-biology-grade single-cell measurements. As a unified pr
“Nature 2006, 442, 403-411”
written · p. 1 · 2006-01-01 · open
Jun group, UCSD · openie_prior_art · en
4Mother machine: high-throughput single-bacterium tracking (Jun group, UCSD, 2010): The 'mother machine': arrays of dead-end channels each holding a single bacterium with daughter cells flushed downstream. Enables thousands of independent single-cell lineage observations in parallel. Anticipates: dead-end-channel single-bacterium trap array architecture, time-resolved bacterial physiology measurements at scale, and the broader category of microfluidic devices for systematic ba
“Curr. Biol. 2010, 20, 1099–1103”
written · p. 1 · 2010-01-01 · open
Andrew Karnis; Stanley G. Mason · openie_prior_art · en
5Karnis & Mason 1963 - Particle migration in Poiseuille flow (Andrew Karnis; Stanley G. Mason, 1963): Karnis-Mason 1963 systematically documents particle and drop migration in Poiseuille and shear flow, including wall-migration of deformable drops. Anticipates droplet-focusing microfluidic claims keyed on drop deformability, cell-sorting by deformability in inertial channels (Di Carlo deformability cytometry), and any 'cross-stream migration' patent for cells or droplets in la
“J. Colloid Sci. 18, 257 (1963)”
written · p. 1 · 1963-01-01 · open
Paul Langevin · openie_prior_art · en
6Langevin 1908 — Stochastic Equation for Brownian Motion (Paul Langevin, 1908): Langevin's stochastic differential equation underpins all numerical simulation of Brownian dynamics in microfluidic systems (single-particle tracking, electrokinetic transport at low ionic concentration, optical-tweezers calibration on chip). Anticipates patent claims to 'simulation-driven control of microfluidic particle trajectories' that rest on Langevin dynamics, particularly in the context of
“C. R. Acad. Sci. (Paris) 146, 530 (1908)”
written · p. 1 · 1908-01-01 · open
Mehmet Toner group, Massachusetts General Hospital / Harvard (with Haber, Maheswaran) · openie_prior_art · en
7Nagrath 2007 isolation of rare circulating tumour cells in cancer patients by microchip technology (CTC-chip) (Mehmet Toner group, Massachusetts General Hospital / Harvard (with Haber, Maheswaran), 2007-12-20): The founding circulating-tumor-cell microchip: a flow chamber packed with tens of thousands of antibody (anti-EpCAM)-functionalized microposts whose geometry and spacing are optimized so that cells in unprocessed whole blood collide with post surfaces frequently enough
“Nature 2007, 450, 1235-1239”
written · p. 1 · 2007-01-01 · open
Heinemann, Lee labs (ETH / Berkeley) · openie_prior_art · en
8Microfluidic bioreactor for individual yeast cells (Heinemann, Lee labs (ETH / Berkeley), 2011): Microfluidic device for whole-lifespan single-yeast-cell observation: cells trapped in posts that retain mother cells while flushing daughter cells, allowing 50+ cell-division observations without moving the trap. Anticipates: lifespan-tracking microfluidic single-cell traps, used widely in aging research and in synthetic-biology dynamics measurement.
“Proc. Natl. Acad. Sci. USA 2012, 109, 4916–4920”
written · p. 1 · 2011-01-01 · open
Voldman, Jaenisch labs (MIT / Whitehead) · openie_prior_art · en
9Microfluidic cell-pairing trap arrays for cell fusion (Voldman, Jaenisch labs (MIT / Whitehead), 2009): Disclosed weir-trap cell-pairing arrays: paired wells with hydrodynamic capture geometry that traps exactly two cells per well in defined order. Anticipates: addressable cell-pairing on chip for fusion / cytotoxicity / interaction studies, and the broader category of hydrodynamic-trap arrays for deterministic single-cell positioning. Distinct architectural primitive from dr
“Nat. Methods 2009, 6, 147–152”
written · p. 1 · 2009-01-01 · open
Beckman Coulter (Danaher) · openie_prior_art · en
10Beckman Vi-CELL XR Cell Viability Trypan Blue Cuvette (Beckman Coulter (Danaher)): Beckman Vi-CELL XR Cell Viability Trypan Blue Cuvette [Subsystems: pump-peristaltic-on-chip, detection-label-free-imaging, cell-trap-hydrodynamic, architecture-stat-test-cartridge; CPC: G01N 15/14, G01N 33/483]
“Beckman Coulter Vi-CELL XR launch 2003; product datasheet; pharmaceutical bioprocess QC adoption (USP <90>)”
written · p. 1 · 2026-05-01 · open
Cellix Ltd. · openie_prior_art · en
11Cellix VenaPlus Microfluidic Multi-Channel Bioplate (Cellix Ltd.): Cellix VenaPlus Microfluidic Multi-Channel Bioplate [Subsystems: fabrication-thermoplastic-injection-molding, cell-trap-hydrodynamic, interface-pressure-manifold; CPC: B01L 3/5085, C12M 23/12]
“Cellix Ltd. product datasheet 'VenaPlus 8'; cellixltd.com; ECVAM-validated white papers”
written · p. 1 · 2026-05-01 · open
Akane Shimizu / Kodansha / David Production · openie_prior_art · en
12Cells at Work! anthropomorphized platelet wound-clot deployment (Akane Shimizu / Kodansha / David Production): Cells at Work! anthropomorphized platelet wound-clot deployment [Subsystems: cell-trap-hydrodynamic, separation-affinity-capture, detection-label-free-imaging; CPC: A61L 24/00, B01L 3/00, A61B 5/00]
“Shimizu, A. Hataraku Saibou (Cells at Work!) manga, serialized in Monthly Shonen Sirius (Kodansha) from 2015-01-26; anime adaptation by David Production, broadcast 2018-07-08 onward. The platelet wound-clot team scenes (manga chapter 1, ani”
written · p. 1 · 2026-05-01 · open
Akane Shimizu / David Production · openie_prior_art · en
13Cells at Work! erythrocyte oxygen-delivery route through alveolar capillary bed (Akane Shimizu / David Production): Cells at Work! erythrocyte oxygen-delivery route through alveolar capillary bed [Subsystems: cell-trap-hydrodynamic, separation-membrane-filtration-on-chip, detection-label-free-imaging; CPC: B01D 53/22, B01L 3/00, A61M 1/16]
“Cells at Work! (David Production / 2018-07-08) episode 1 'Pneumococcus'; the red blood cell AE3803s delivery route through the alveolar capillary bed is depicted with explicit single-file capillary flow, gas-exchange across alveolar wall, a”
written · p. 1 · 2026-05-01 · open
Maurice Couette · openie_prior_art · en
14Couette 1890 — Concentric Cylinder Viscometer and Couette Flow (Maurice Couette): Couette 1890 — Concentric Cylinder Viscometer and Couette Flow [Subsystems: mixer-active-acoustic, cell-trap-hydrodynamic; CPC: G01N 11/14, C12M 23/16]
“Couette, M. (1890). 'Etudes sur le frottement des liquides.' Annales de Chimie et de Physique Series 6, 21: 433-510; abridged Couette, M. (1890). J. Phys. Theor. Appl. 9(1): 414-417. doi:10.1051/jphystap:018900090041401”
written · p. 1 · 1890-01-01 · open
L. P. Lee, Di Carlo (UC Berkeley) · openie_prior_art · en
15Microfluidic cell-trap array for single-cell analysis (L. P. Lee, Di Carlo (UC Berkeley)): Microfluidic cell-trap array for single-cell analysis [Subsystems: cell-trap-hydrodynamic, fabrication-pdms-soft-lithography; CPC: B01L 3/00, C12M 1/00]
“Di Carlo, D.; Aghdam, N.; Lee, L. P. Single-cell enzyme concentrations, kinetics, and inhibition analysis using high-density hydrodynamic cell isolation arrays. Anal. Chem. 2006, 78, 4925–4930. DOI: 10.1021/ac060541s”
written · p. 1 · 2026-05-01 · open
Klavs F. Jensen and Peter K. Sorger groups, MIT · openie_prior_art · en
16El-Ali 2006 cells on chips (Klavs F. Jensen and Peter K. Sorger groups, MIT): El-Ali 2006 cells on chips [Subsystems: fabrication-pdms-soft-lithography, cell-trap-hydrodynamic, cell-organoid-perfusion, cell-poration-mechanical-shear, mixer-passive-interleaved-streams, detection-fluorescence-on-chip; CPC: B01L 3/00, C12M 1/00, C12M 3/00, G01N 33/50]
“El-Ali, J.; Sorger, P. K.; Jensen, K. F. Cells on chips. Nature 2006, 442, 403-411. DOI: 10.1038/nature05063”
written · p. 1 · 2006-01-01 · open
Jun group, UCSD · openie_prior_art · en
17Mother machine: high-throughput single-bacterium tracking (Jun group, UCSD): Mother machine: high-throughput single-bacterium tracking [Subsystems: cell-trap-hydrodynamic, fabrication-pdms-soft-lithography; CPC: B01L 3/00, C12M 1/00]
“Wang, P.; Robert, L.; Pelletier, J.; Dang, W. L.; Taddei, F.; Wright, A.; Jun, S. Robust growth of Escherichia coli. Curr. Biol. 2010, 20, 1099–1103. DOI: 10.1016/j.cub.2010.04.045”
written · p. 1 · 2026-05-01 · open
FLIR Systems (via ICx Technologies / BioVigilant); related fielded units include the US JBPDS triggers · openie_prior_art · en
18FLIR IBAC bioaerosol identifier and particulate-collector unit (FLIR Systems (via ICx Technologies / BioVigilant); related fielded units include the US JBPDS triggers): FLIR IBAC bioaerosol identifier and particulate-collector unit [Subsystems: detection-fluorescence-on-chip, separation-inertial-focusing, cell-trap-hydrodynamic, detection-impedance-cytometry, architecture-stat-test-cartridge; CPC: G01N 15/1434, G01N 21/64, G01N 1/2202, G01N 33/483]
“US20040159799A1 / US7126687B2 Method and instrument for detecting biological agents in aerosol (Hairston/Ho-style UV laser-induced fluorescence; ICx BioVigilant / FLIR lineage); see also Ho, Future of biological aerosol detection, Anal. Chi”
written · p. 1 · 2026-05-01 · open
Fluidigm Corp. (now Standard BioTools) · openie_prior_art · en
19Fluidigm C1 single-cell auto prep system (Fluidigm Corp. (now Standard BioTools)): Fluidigm C1 single-cell auto prep system [Subsystems: valve-quake-pneumatic-membrane, cell-trap-hydrodynamic, fabrication-pdms-soft-lithography, thermal-pcr-cycling, architecture-multiplex-cartridge; CPC: B01L 3/00, C12Q 1/6806]
“Fluidigm Corp. C1 Single-Cell Auto Prep System product launch 2012. Pollen, A. A. et al. Low-coverage single-cell mRNA sequencing reveals cellular heterogeneity and activated signaling pathways in developing cerebral cortex. Nat. Biotechnol”
written · p. 1 · 2026-05-01 · open
DVS Sciences (acquired by Fluidigm 2014, now Standard BioTools) · openie_prior_art · en
20DVS Sciences / Fluidigm CyTOF Mass Cytometry Patent Family (DVS Sciences (acquired by Fluidigm 2014, now Standard BioTools)): DVS Sciences / Fluidigm CyTOF Mass Cytometry Patent Family [Subsystems: dispenser-pipettor, detection-mass-spec-electrospray-coupled, cell-trap-hydrodynamic; CPC: G01N 33/532, H01J 49/04]
“US8525107; US8101368; US8278116; US8679858 originally assigned to DVS Sciences (Bandura, Tanner et al.), acquired by Fluidigm 2014-02-13 for $207.5M”
written · p. 1 · 2026-05-01 · open
Fluxion Biosciences Inc. · openie_prior_art · en
21Fluxion Biosciences BioFlux 1000z Cell Adhesion System (Fluxion Biosciences Inc.): Fluxion Biosciences BioFlux 1000z Cell Adhesion System [Subsystems: fabrication-thermoplastic-injection-molding, interface-pressure-manifold, cell-trap-hydrodynamic; CPC: B01L 3/5085, C12M 23/12]
“Conant CG et al., J Lab Autom 16:148-152 (2011); doi:10.1016/j.jala.2010.10.001; Fluxion Biosciences product literature; fluxionbio.com”
written · p. 1 · 2026-05-01 · open
Andrew Karnis; Stanley G. Mason · openie_prior_art · en
22Karnis & Mason 1963 - Particle migration in Poiseuille flow (Andrew Karnis; Stanley G. Mason): Karnis & Mason 1963 - Particle migration in Poiseuille flow [Subsystems: separation-inertial-focusing, cell-trap-hydrodynamic; CPC: B01L 3/502, B03B 5/30]
“Karnis, A., Mason, S. G. (1963). 'Particle motions in sheared suspensions: XXIII. Wall migration of fluid drops.' J. Colloid Sci. 18: 257-281.”
written · p. 1 · 1963-01-01 · open
Paul Langevin · openie_prior_art · en
23Langevin 1908 — Stochastic Equation for Brownian Motion (Paul Langevin): Langevin 1908 — Stochastic Equation for Brownian Motion [Subsystems: cell-trap-hydrodynamic, detection-label-free-imaging; CPC: G01N 15/02]
“Langevin, P. (1908). 'Sur la theorie du mouvement brownien.' Comptes Rendus de l'Academie des Sciences (Paris) 146: 530-533.”
written · p. 1 · 1908-01-01 · open
Mehmet Toner group, Massachusetts General Hospital / Harvard (with Haber, Maheswaran) · openie_prior_art · en
24Nagrath 2007 isolation of rare circulating tumour cells in cancer patients by microchip technology (CTC-chip) (Mehmet Toner group, Massachusetts General Hospital / Harvard (with Haber, Maheswaran)): Nagrath 2007 isolation of rare circulating tumour cells in cancer patients by microchip technology (CTC-chip) [Subsystems: fabrication-silicon-drie, separation-affinity-capture, cell-trap-hydrodynamic, detection-label-free-imaging, surface-functionalization-silane; CPC: B01L 3/502
“Nagrath, S.; Sequist, L. V.; Maheswaran, S.; Bell, D. W.; Irimia, D.; Ulkus, L.; Smith, M. R.; Kwak, E. L.; Digumarthy, S.; Muzikansky, A.; Ryan, P.; Balis, U. J.; Tompkins, R. G.; Haber, D. A.; Toner, M. Isolation of rare circulating tumou”
written · p. 1 · 2007-01-01 · open
Heinemann, Lee labs (ETH / Berkeley) · openie_prior_art · en
25Microfluidic bioreactor for individual yeast cells (Heinemann, Lee labs (ETH / Berkeley)): Microfluidic bioreactor for individual yeast cells [Subsystems: cell-trap-hydrodynamic, fabrication-pdms-soft-lithography; CPC: B01L 3/00, C12M 1/00]
“Lee, S. S.; Avalos Vizcarra, I.; Huberts, D. H. E. W.; Lee, L. P.; Heinemann, M. Whole lifespan microscopic observation of budding yeast aging through a microfluidic dissection platform. Proc. Natl. Acad. Sci. USA 2012, 109, 4916–4920. DOI:”
written · p. 1 · 2026-05-01 · open
Sight Diagnostics · openie_prior_art · en
26Sight Diagnostics OLO patent family (Sight Diagnostics): Sight Diagnostics OLO patent family [Subsystems: detection-label-free-imaging, cell-trap-hydrodynamic; CPC: ]
“Sight Diagnostics Ltd (Tel Aviv) IP estate; IL/US/PCT filings 2014-present”
written · p. 1 · 2026-05-01 · open
Voldman, Jaenisch labs (MIT / Whitehead) · openie_prior_art · en
27Microfluidic cell-pairing trap arrays for cell fusion (Voldman, Jaenisch labs (MIT / Whitehead)): Microfluidic cell-pairing trap arrays for cell fusion [Subsystems: cell-trap-hydrodynamic, fabrication-pdms-soft-lithography; CPC: B01L 3/00, C12M 1/00]
“Skelley, A. M.; Kirak, O.; Suh, H.; Jaenisch, R.; Voldman, J. Microfluidic control of cell pairing and fusion. Nat. Methods 2009, 6, 147–152. DOI: 10.1038/nmeth.1290”
written · p. 1 · 2026-05-01 · open
Advanced Instruments / Solentim Ltd · openie_prior_art · en
28Advanced Instruments / Solentim VIPS PRO single-cell deposition system (Advanced Instruments / Solentim Ltd): Advanced Instruments / Solentim VIPS PRO single-cell deposition system [Subsystems: droplet-on-demand, detection-label-free-imaging, cell-trap-hydrodynamic; CPC: B01L 3/00, C12M 1/26, G01N 21/00]
“Solentim Ltd (acquired by Advanced Instruments 2021). VIPS launch 2017; VIPS PRO launch 2020. https://www.advancedinstruments.com/products/vips-pro.html. Patent family: US11149236B2 (Solentim; priority 2016).”
written · p. 1 · 2026-05-01 · open
Fluidigm (now Standard BioTools) · openie_prior_art · en
29Standard BioTools (formerly Fluidigm) C1 single-cell genomics IFC (Fluidigm (now Standard BioTools)): Standard BioTools (formerly Fluidigm) C1 single-cell genomics IFC [Subsystems: valve-quake-pneumatic-membrane, cell-trap-hydrodynamic, fabrication-pdms-soft-lithography, thermal-pcr-cycling; CPC: B01L 3/00, C12Q 1/6841]
“Fluidigm Corp. C1 system (now Standard BioTools). Pollen et al. 2014 Nat. Biotechnol. 32, 1053–1058. DOI: 10.1038/nbt.2967”
written · p. 1 · 2026-05-01 · open
OpenIE Microfluidics Commons · openie_microfluidics_cad · en
30Mother machine bacterial trap array (Wang/Jun 2010 reference): Main flow channel 100 µm × 25 µm with arrays of perpendicular dead-end trenches 1.2 µm wide × 25 µm long × 1.0 µm tall — sized to hold a single bacterial cell (typ. E. coli 1 µm × 2 µm) at the closed end while excluding subsequent daughter cells via flow
“Main flow channel 100 µm × 25 µm with arrays of perpendicular dead-end trenches 1.2 µm wide × 25 µm long × 1.0 µm tall — sized to hold a single bacterial cell (typ. E. coli 1 µm × 2 µm) at the closed end while excluding subsequent daughter ”
written · p. 1 · 2026-05-09 · open