← concepts · the commons
chip-PDMS-soft-lithography
also known as fabrication-pdms-glass-soft-lithography · fabrication-soft-lithography · fabrication-pdms-soft-lithography · fabrication-multilayer-soft-lithography · fabrication-soft-lithography-pdms
232 moment(s) that assert this concept — showing 1–50 of 232
moderateTwo independent sources — corroborated, but not broadly
↣ how this spread over time →reuse terms across this evidence: 50 openly licensed
scholarly papers (3)
Anna, Bontoux, Stone (Harvard) · openie_prior_art · en
1Flow-focusing droplet generation in microfluidic devices (Anna, Bontoux, Stone (Harvard), 2003): Established flow-focusing droplet generation as a parallel architecture to the T-junction. Disclosed: a continuous-phase fluid focuses a dispersed-phase stream through a constriction, forming droplets at controllable rates and sizes. This geometry underlies most modern droplet platforms (10x Genomics-style microfluidic chips, Bio-Rad ddPCR generators, etc.).
“Appl. Phys. Lett. 2003, 82, 364–366”
written · p. 1 · 2003-01-01 · open
Studer group, ESPCI · openie_prior_art · en
2NOA-81 (Norland Optical Adhesive) microfluidic chip fabrication (Studer group, ESPCI, 2008): Disclosed NOA-81 (Norland Optical Adhesive 81) microfluidic chip fabrication: UV-curable thiol-ene polymer cast against PDMS master and bonded to glass without plasma activation. Architectural alternative to PDMS that addresses PDMS's well-known limitations: hydrophobicity recovery, small-molecule absorption, gas permeability. Anticipates: thiol-ene-as-microfluidic-substrate, and the
“Lab Chip 2008, 8, 274–279”
written · p. 1 · 2008-01-01 · open
Beebe group (UIUC / Wisconsin) · openie_prior_art · en
3Stop-flow lithography and Beebe geometry (Beebe group (UIUC / Wisconsin), 2000): Disclosed pH-responsive hydrogel structures photopatterned in situ inside microchannels to act as autonomous valves and chemostat-like sensors. Anticipates: in-channel photopolymerized hydrogel valves, stimulus-responsive autonomous flow regulation, and the entire 'smart hydrogel' microfluidics subfield. Among the most-cited microfluidics papers and a foundational primitive distinct from Quake-st
“Nature 2000, 404, 588–590”
written · p. 1 · 2000-01-01 · open
Quake group, Caltech · openie_prior_art · en
4Microfluidic flow cytometer architectures (academic) (Quake group, Caltech, 2002): The first microfabricated FACS — fluorescence-activated cell sorter on chip. Demonstrated cell sorting at modest throughput (~10 cells/s) with optical interrogation and pneumatic actuation in PDMS. Anticipates: chip-FACS architecture, microfluidic flow cytometry, and the entire chip-based flow cytometry subfield subsequently expanded by Sony SP6800, BD Cytopeia, On-chip Sort, and others.
“Nat. Biotechnol. 1999, 17, 1109–1111”
written · p. 1 · 2002-01-01 · open
Sangeeta N. Bhatia (MIT) and Donald E. Ingber (Wyss Institute, Harvard) · openie_prior_art · en
5Bhatia and Ingber 2014 microfluidic organs-on-chips (Sangeeta N. Bhatia (MIT) and Donald E. Ingber (Wyss Institute, Harvard), 2014-08-05): The seminal organ-on-chip review: it codifies the two-channel porous-membrane microdevice architecture with cyclic mechanical actuation that reconstitutes organ-level structure and function (lung, gut, liver, kidney, heart, blood-brain barrier, bone marrow), the perfusion schemes that mimic vascular and interstitial flow, and the linked-or
“Nat. Biotechnol. 2014, 32, 760-772”
written · p. 1 · 2014-01-01 · open
Yarmush, Taylor labs (MGH / Pittsburgh) · openie_prior_art · en
6Liver hepatocyte sandwich-culture on chip (Yarmush, Taylor labs (MGH / Pittsburgh), 2013): Disclosed 3D liver-on-chip: hepatocyte sandwich-culture in microfluidic perfusion device for hepatotoxicity drug screening. Architecturally an organ-chip variant emphasizing 3D tissue rather than dual-channel architecture. Anticipates: 3D-cultured-hepatocyte microfluidic platform, and the drug-induced-liver-injury (DILI) screening application that drove much of the early commercial orga
“Stem Cell Res. Ther. 2013, 4, S16”
written · p. 1 · 2013-01-01 · open
Broad Institute / Harvard / Steve McCarroll laboratory · openie_prior_art · en
7Broad Institute Drop-seq Patent Family (Macosko / McCarroll lineage) (Broad Institute / Harvard / Steve McCarroll laboratory, 2013-04-26): Broad Institute / Harvard / McCarroll lab patent family for Drop-seq. Anchors claims around: (a) microfluidic flow-focusing co-encapsulation of a single cell with a single barcoded bead and lysis buffer in an aqueous-in-oil droplet; (b) bead-bound primer architecture (PCR handle + cell barcode + UMI + poly-T capture); (c) cell lysis in dro
“US10221442B2 USPTO grant text”
written · p. 1 · 2013-01-01 · open
van der Wijngaart, Carlborg, Haraldsson (KTH Stockholm) · openie_prior_art · en
8OSTE (off-stoichiometry thiol-ene) microfluidic substrates (van der Wijngaart, Carlborg, Haraldsson (KTH Stockholm), 2011): Disclosed OSTE (off-stoichiometry thiol-ene) substrate for microfluidics: a tunable photopolymer with controllable surface chemistry, mechanical properties, and bonding behavior. The OSTE+ variant adds reactive surface chemistry that allows direct chemical bonding to other substrates. Architectural alternative to PDMS for chips needing tuned surface chem
“Lab Chip 2011, 11, 3136–3147”
written · p. 1 · 2011-01-01 · open
Beebe group, UIUC / Wisconsin · openie_prior_art · en
9PEGDA hydrogel photopatterning in microfluidic channels (Beebe group, UIUC / Wisconsin, 2003): Beebe-group establishment of in-channel PEGDA hydrogel photopatterning as a route to autonomous valve and trap structures. Subsequent papers (post Beebe 2000 Nature) demonstrated systematic PEGDA structure formation, sub-100 µm feature definition, and biocompatible cell encapsulation in situ. Anticipates: PEGDA as the canonical photopatternable hydrogel for chips, distinct from the
“Annu. Rev. Biomed. Eng. 2002, 4, 261–286”
written · p. 1 · 2003-01-01 · open
Daniel T. Chiu group, University of Washington · openie_prior_art · en
10Chiu and Lorenz 2009 chemistry and biology in femtoliter and picoliter volume droplets (Daniel T. Chiu group, University of Washington, 2009-04-21): An authoritative account of using femtoliter-to-picoliter droplets as reaction vessels for single-molecule and single-cell chemistry and biology: methods to generate, transport, trap (optical tweezers), fuse, and split ultrasmall aqueous droplets in immiscible carrier fluids, and the concentration-enhancement and stochastic-confi
“Acc. Chem. Res. 2009, 42, 649-658”
written · p. 1 · 2009-01-01 · open
various — Lee, Weitz, Doyle (early 2000s contributions) · openie_prior_art · en
11Microfluidic alginate microbead generation (various — Lee, Weitz, Doyle (early 2000s contributions), 2007): Foundational disclosure of microfluidic alginate microbead generation: aqueous alginate flow-focused into oil with downstream calcium-mediated gelation produces monodisperse alginate microbeads suitable for cell encapsulation. Anticipates: alginate-as-microbead-substrate-in-droplet-microfluidics, which became the backbone of single-cell sequencing platforms (Drop-seq, i
“Biomed. Microdevices 2007, 9, 855–862”
written · p. 1 · 2007-01-01 · open
Whitesides group, Harvard · openie_prior_art · en
12Generation of gradients having complex shapes using microfluidic networks (Whitesides group, Harvard, 2001): Disclosed the iconic 'Christmas tree' splitting-and-recombining microfluidic network for arbitrary-shape concentration gradient generation. Anticipates: branched diffusion-mixer cascade for gradient generation, parallel-channel concentration gradient as a primitive in chemotaxis assays, and the gradient-generator microfluidic motif appearing in hundreds of subsequent c
“Anal. Chem. 2001, 73, 1240–1246”
written · p. 1 · 2001-01-01 · open
L. P. Lee, Di Carlo (UC Berkeley) · openie_prior_art · en
13Microfluidic cell-trap array for single-cell analysis (L. P. Lee, Di Carlo (UC Berkeley), 2006): Disclosed high-density hydrodynamic cell trap array: PDMS chip with serial-arranged U-shaped cup traps, each capturing exactly one cell from flowing suspension by streamline-following. Anticipates: U-cup hydrodynamic single-cell trap as a primitive, addressable single-cell observation arrays, and the architectural pattern subsequently elaborated by Tay-group and others for time-re
“Anal. Chem. 2006, 78, 4925–4930”
written · p. 1 · 2006-01-01 · open
Di Carlo, Toner et al. (Harvard / Mass General) · openie_prior_art · en
14Continuous inertial focusing, ordering, and separation of particles in microchannels (Di Carlo, Toner et al. (Harvard / Mass General), 2007): Established inertial microfluidics as a continuous-flow particle-separation regime exploiting Dean drag and shear-gradient lift in curving and straight channels at intermediate Reynolds numbers (Re~10–100). Anticipates: spiral and serpentine inertial focusing geometries, label-free CTC enrichment by inertial migration, sheath-free parti
“Proc. Natl. Acad. Sci. USA 2007, 104, 18892–18897”
written · p. 1 · 2007-01-01 · open
T. J. Huang group, Penn State / Duke · openie_prior_art · en
15Standing surface acoustic wave (SSAW) acoustic tweezers (T. J. Huang group, Penn State / Duke, 2012): Disclosed SSAW (standing surface acoustic wave) micromanipulation of cells and microparticles in a PDMS channel atop a lithium niobate substrate with paired IDTs. Anticipates: IDT-on-LiNbO3 SSAW architecture for sub-mm patterning of pressure nodes in solution, individually addressable cell trapping by SAW phase shifting, and the SAW microfluidics paradigm that competes with L
“Proc. Natl. Acad. Sci. USA 2012, 109, 11105–11109”
written · p. 1 · 2012-01-01 · open
Whitesides group, Harvard · openie_prior_art · en
16Rapid prototyping of microfluidic systems in PDMS (Whitesides group, Harvard, 1998): The paper that turned PDMS soft lithography into the default microfluidics fabrication method for the next 25+ years. Anticipates: SU-8 master mold + PDMS replica casting, oxygen-plasma bonding of PDMS to glass or PDMS, hydrophilic surface treatment by plasma oxidation, and rapid-prototyping iteration of channel designs. Any patent claiming novelty over 'PDMS replica molding from a photoresis
“Anal. Chem. 1998, 70, 4974–4984”
written · p. 1 · 1998-01-01 · open
Allbritton group, UC Irvine · openie_prior_art · en
17PEG grafting on PDMS for surface passivation (Allbritton group, UC Irvine, 2003): Established UV-initiated PEG grafting on PDMS as a route to non-fouling, non-protein-adsorbing PDMS microfluidic surfaces. Anticipates: PEG-grafted PDMS as a standard surface treatment for cell-culture and protein-handling chips, addressing PDMS's well-known protein-adsorption problem. Sub-strate-side counterpart to Quake-LSI's plumbing-side innovations.
“Anal. Chem. 2002, 74, 4117–4123”
written · p. 1 · 2003-01-01 · open
Klavs F. Jensen and Peter K. Sorger groups, MIT · openie_prior_art · en
18El-Ali 2006 cells on chips (Klavs F. Jensen and Peter K. Sorger groups, MIT, 2006-07-27): The canonical Nature-insight review of cell biology on microfluidic chips: single-cell hydrodynamic and other trapping, perfusion culture with controlled microenvironments, microfluidic concentration-gradient generators, dynamic-stimulus delivery, on-chip lysis, and integration with downstream nucleic-acid/protein assays for systems-biology-grade single-cell measurements. As a unified pr
“Nature 2006, 442, 403-411”
written · p. 1 · 2006-01-01 · open
Dongeun (Dan) Huh group, University of Pennsylvania (with A. Bahinski) · openie_prior_art · en
19Esch 2015 organs-on-chips at the frontiers of drug discovery (Dongeun (Dan) Huh group, University of Pennsylvania (with A. Bahinski), 2015-03-13): The Nature Reviews Drug Discovery survey of organ-on-chip / microphysiological systems specifically as drug-discovery tools: where in the pipeline (target validation, lead optimization, ADME-Tox, surrogate clinical trials) chip models add predictive value over animals and static culture, how multi-organ chips model systemic pharmac
“Nat. Rev. Drug Discov. 2015, 14, 248-260”
written · p. 1 · 2015-01-01 · open
James R. Heath group, Caltech (with Leroy Hood, ISB) · openie_prior_art · en
20Fan 2008 integrated barcode chips for rapid multiplexed analysis of proteins in microliter quantities of blood (James R. Heath group, Caltech (with Leroy Hood, ISB), 2008-11-16): Discloses the integrated antibody-barcode chip: a glass surface flow-patterned with stripes of distinct DNA-encoded antibodies (DEAL chemistry), bonded to a PDMS microfluidic layer that on-chip separates plasma from a microliter whole-blood drop (no centrifuge) and routes it across the barcode for a
“Nat. Biotechnol. 2008, 26, 1373-1378”
written · p. 1 · 2008-01-01 · open
Jun group, UCSD · openie_prior_art · en
21Mother machine: high-throughput single-bacterium tracking (Jun group, UCSD, 2010): The 'mother machine': arrays of dead-end channels each holding a single bacterium with daughter cells flushed downstream. Enables thousands of independent single-cell lineage observations in parallel. Anticipates: dead-end-channel single-bacterium trap array architecture, time-resolved bacterial physiology measurements at scale, and the broader category of microfluidic devices for systematic ba
“Curr. Biol. 2010, 20, 1099–1103”
written · p. 1 · 2010-01-01 · open
Whitesides / Stone groups, Harvard · openie_prior_art · en
22Garstecki 2006 formation of droplets and bubbles in a microfluidic T-junction (Whitesides / Stone groups, Harvard, 2006-02-08): The anchor reference for T-junction droplet generation: it identifies the squeezing regime in which the dispersed phase obstructs the main channel and break-up is driven by the upstream pressure rise rather than by viscous shear, and derives the linear scaling droplet-length = 1 + alpha*(flow-rate ratio) that has become the standard T-junction design
“Lab Chip 2006, 6, 437-446”
written · p. 1 · 2006-01-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
23Hansen 2002 robust scalable microfluidic metering for protein crystallization by free interface diffusion (Stephen R. Quake group, Caltech, 2002-12-24): Discloses the microfluidic metering method underlying chip-format protein crystallization: paired nanoliter chambers loaded by dead-end filling, isolated by monolithic membrane valves, then connected through an interface valve so the two reagents mix only by free-interface diffusion - reproducibly sampling a crystallization t
“Proc. Natl. Acad. Sci. U.S.A. 2002, 99, 16531-16536”
written · p. 1 · 2002-01-01 · open
Henry Selby Hele-Shaw · openie_prior_art · en
24Hele-Shaw 1898 — The Flow of Water (Hele-Shaw Cell) (Henry Selby Hele-Shaw, 1898-05-12): Discloses the canonical thin-slit geometry now ubiquitous in microfluidic chip design. Every PDMS or glass slit-channel device that is wider than it is tall operates in the Hele-Shaw regime, and Hele-Shaw 1898 is the explicit prior art for: (a) all 'flat-channel microfluidic chip' geometries that claim depth-averaged flow behavior; (b) viscous fingering experiments (Saffman-Taylor 1958);
“Nature 58, 34 (1898) doi:10.1038/058034a0”
written · p. 1 · 1898-01-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
25Hong and Quake 2003 integrated nanoliter systems (Stephen R. Quake group, Caltech, 2003-10-01): The canonical mid-period statement of microfluidic large-scale integration: assembling thousands of monolithic-membrane valves into multiplexers, peristaltic pumps, rotary mixers, on-chip columns and addressable chamber arrays for nanoliter-scale biochemistry and genomics. Discloses (in a unified review form) the multiplexer scheme that addresses N independent fluidic lines with or
“Nat. Biotechnol. 2003, 21, 1179-1183”
written · p. 1 · 2003-01-01 · open
Jong Wook Hong, Vincent Studer, Stephen R. Quake, Caltech · openie_prior_art · en
26A nanoliter-scale nucleic acid processor with parallel architecture (Hong, Studer, Hang, Anderson, Quake, 2004) (Jong Wook Hong, Vincent Studer, Stephen R. Quake, Caltech, 2004-03-21): An integrated PDMS lab-on-a-chip that performs the full nucleic-acid-preparation workflow - cell isolation, lysis, mRNA/DNA capture on functionalized beads, washing, and recovery of purified product - in parallel nanolitre reactors, built entirely from multilayer-soft-lithography pneumatic memb
“Hong, J. W.; Studer, V.; Hang, G.; Anderson, W. F.; Quake, S. R. Nat. Biotechnol. 2004, 22, 435-439; DOI 10.1038/nbt951”
written · p. 1 · 2004-01-01 · open
T. J. Huang group, Penn State · openie_prior_art · en
27Acoustic-streaming sharp-edge cell trap (T. J. Huang group, Penn State, 2013): Disclosed acoustic-streaming sharp-edge mixer architecture: a piezoelectric chip excites oscillation of patterned sharp PDMS edges, generating localized streaming vortices that mix at low Re. Anticipates: sharp-edge-as-streaming-source as a primitive for acoustic mixing on chip, and an alternative to bubble-driven streaming. Used in subsequent T. J. Huang acoustofluidic papers.
“Lab Chip 2013, 13, 3847–3852”
written · p. 1 · 2013-01-01 · open
Hilgenfeldt group / A. Lee group (UCI) · openie_prior_art · en
28Acoustic-streaming microvortex cell trap (Hilgenfeldt group / A. Lee group (UCI), 2009): Established oscillating air-liquid interface as a microstreaming-vortex cell trap: a piezoactuated chip drives oscillation of trapped bubbles, which generate steady-streaming microvortices that capture cells. Direct architectural ancestor of the AESOP work (Zhang 2026) which uses the same trap mechanism for sequential transfection. Anticipates: bubble-driven steady-streaming microvortex c
“Appl. Phys. Lett. 2011, 99, 034101”
written · p. 1 · 2009-01-01 · open
Takayama group, Michigan · openie_prior_art · en
29Acoustically detectable cellular-level lung injury model (Takayama group, Michigan, 2007): Direct precursor to the Huh-Ingber 2010 lung-on-chip paper; demonstrated airway-stress modeling in PDMS chips. Establishes the Takayama-group lineage that connects to Ingber's Wyss Institute lung-on-chip and ultimately Emulate's commercial platform. Important for tracing the academic-to-commercial pathway of organ-on-chip work.
“Proc. Natl. Acad. Sci. USA 2007, 104, 18886–18891”
written · p. 1 · 2007-01-01 · open
Donald Ingber group, Wyss Institute · openie_prior_art · en
30Lung-on-a-chip (Donald Ingber group, Wyss Institute, 2010): The foundational organ-on-chip disclosure: lung alveolar-capillary interface reconstituted on a microfluidic chip with cyclic mechanical stretch. Anticipates: dual-channel architecture with intervening porous membrane, mechanical actuation of cell-bearing membranes via pneumatic chambers, perfused human cell co-culture with epithelial-endothelial interfaces. Spawned the Emulate Inc. commercial platform and the entire
“Science 2010, 328, 1662–1668”
written · p. 1 · 2010-01-01 · open
Donald E. Ingber group, Wyss Institute, Harvard · openie_prior_art · en
31Huh 2013 microfabrication of human organs-on-chips (Nature Protocols) (Donald E. Ingber group, Wyss Institute, Harvard, 2013-10-10): The published fabrication protocol for the Wyss Institute organ-on-chip: how to mold the two parallel microchannels, cast and handle the thin porous PDMS membrane, plasma-bond the layers in alignment, etch the flanking side chambers, and apply cyclic vacuum to mechanically strain the cell-bearing membrane - the canonical recipe behind the lung/g
“Nat. Protoc. 2013, 8, 2135-2157”
written · p. 1 · 2013-01-01 · open
Ingber group, Wyss Institute / Harvard · openie_prior_art · en
32Ingber lab organ-chip platform (Wyss Institute) (Ingber group, Wyss Institute / Harvard, 2010): Wyss-Institute consolidating publication establishing the 'organ-on-chip' research program — direct architectural and IP ancestor of the Emulate Inc. commercial platform. Ingber group's organ-chip lineage covers lung-on-chip (Huh 2010), gut-on-chip, kidney-on-chip, blood-brain-barrier-on-chip and others, all sharing the dual-channel PDMS architecture with vacuum-driven mechanical s
“Trends Cell Biol. 2011, 21, 745–754”
written · p. 1 · 2010-01-01 · open
Instituto Nacional de Tecnologia Industrial (INTI), Buenos Aires · openie_prior_art · en
33INTI microfluidics and bioanalytical metrology programs (Instituto Nacional de Tecnologia Industrial (INTI), Buenos Aires, 2010): Institute-estate entry. INTI prototypes microfluidic devices and develops the metrology underpinning Argentine diagnostics manufacturing. Background prior art for soft-lithography and laser-cut thermoplastic microfluidic prototyping in a national-metrology-institute context. Estate anchor for the Argentine microfluidics ecosystem.
“INTI annual reports and program descriptions”
written · p. 1 · 2010-01-01 · open
Suh / Ingber labs (Wyss Institute) · openie_prior_art · en
34Kidney proximal tubule-on-chip (Suh / Ingber labs (Wyss Institute), 2013): Disclosed kidney proximal tubule-on-chip: dual-channel PDMS with porous membrane and unidirectional shear flow mimicking tubular fluid mechanics, used for nephrotoxicity drug screening. Anticipates: tubule-shear-stress organ-chip architecture, and the FDA-relevant nephrotoxicity drug-screening application that became part of the NIH MPS / FDA Modernization Act 2.0 framework.
“Integr. Biol. 2013, 5, 1119–1129”
written · p. 1 · 2013-01-01 · open
Ingber group, Wyss Institute / Harvard · openie_prior_art · en
35Gut-on-chip with peristalsis-mimicking mechanical strain (Ingber group, Wyss Institute / Harvard, 2012): Disclosed gut-on-chip: dual-channel PDMS architecture similar to lung-on-chip but with peristalsis-mimicking mechanical strain via vacuum-driven side channels, supporting Caco-2 villi formation and microbial co-culture. Anticipates: peristaltic-strain organ-chip architecture, microbial-mammalian co-culture on chip, and the gut-microbiome organ-chip subfield.
“Lab Chip 2012, 12, 2165–2174”
written · p. 1 · 2012-01-01 · open
Klein, Weitz, Kirschner labs (Harvard) · openie_prior_art · en
36inDrops: droplet-based barcoding for single-cell transcriptomics (Klein, Weitz, Kirschner labs (Harvard), 2015): Published one week after Drop-seq; together they establish single-cell droplet RNA-seq as a category. inDrops uses hydrogel-encapsulated barcodes (rather than Drop-seq's polystyrene beads), an architectural choice subsequently inherited by 1Cell-Bio's commercial inDrops platform. Both papers anticipate: massively parallel single-cell RNA-seq via droplet co-encapsul
“Cell 2015, 161, 1187–1201”
written · p. 1 · 2015-01-01 · open
John Rogers group (Northwestern / Illinois) · openie_prior_art · en
37Soft, skin-mounted epidermal microfluidic device for sweat collection and analysis (John Rogers group (Northwestern / Illinois), 2016): Disclosed soft skin-mounted epidermal microfluidic patch with networks of capillary-driven channels, color-changing reagent zones, and smartphone-based readout. Anticipates: PDMS-based skin-conformal microfluidic chip architecture, capillary-driven sweat collection and reservoir storage on body, colorimetric multiplexed analysis with smartpho
“Sci. Transl. Med. 2016, 8, 366ra165”
written · p. 1 · 2016-01-01 · open
Whitesides group, Harvard · openie_prior_art · en
38Features of gold by µCP using PDMS stamps (Whitesides group, Harvard, 1993): The foundational disclosure of microcontact printing: a PDMS stamp inked with alkanethiol creates a self-assembled monolayer pattern on gold, which serves as etch mask for sub-micron metal features. Anticipates: PDMS-stamp pattern transfer as a category, µCP for biological-pattern definition (proteins, cells), and the entire elastomeric-stamp lineage that enabled Duffy 1998's PDMS microchannel work f
“Appl. Phys. Lett. 1993, 63, 2002–2004”
written · p. 1 · 1993-01-01 · open
Densmore lab, Boston University · openie_prior_art · en
39Machine-learning-driven droplet generator design (Lashkaripour 2021/2024) (Densmore lab, Boston University, 2021): Disclosed DAFD (Design Automation of Fluid Dynamics): ML model trained on microfluidic experimental data predicts flow-focusing droplet generator geometry from desired droplet size and rate. Anticipates: ML-as-design-automation for microfluidic chip geometry, and the broader trend of replacing CFD simulation with trained models for microfluidic design.
“Nat. Commun. 2021, 12, 25”
written · p. 1 · 2021-01-01 · open
Landers group, Virginia · openie_prior_art · en
40Magnetic-bead microvalve and pump (Landers group, Virginia, 2009): Disclosed elastomeric features whose pressure-deformation response selectively passes flow at specific frequencies — frequency-specific microfluidic logic gates without active elements. Provides a pure-passive alternative to Quake valves for many on-chip control tasks. Anticipates: frequency-domain microfluidic logic, passive frequency filters as flow control, and architectural designs that eliminate external
“Nat. Phys. 2009, 5, 231–235”
written · p. 1 · 2009-01-01 · open
Weitz / Stone groups, Harvard · openie_prior_art · en
41Link 2004 geometrically mediated breakup of drops in microfluidic devices (Weitz / Stone groups, Harvard, 2004-08-04): Provides the physics of geometrically mediated drop break-up: a drop entering a T-bifurcation either splits or passes intact depending on its initial extension and the capillary number, captured in a quantitative phase diagram, and cascaded bifurcations multiply one mother drop into 2^n monodisperse daughters; obstacles can likewise be used to trigger control
“Phys. Rev. Lett. 2004, 92, 054503”
written · p. 1 · 2004-01-01 · open
R. Fan group, Yale · openie_prior_art · en
42DBiT-seq spatial multi-omics on chip (R. Fan group, Yale, 2020): Disclosed DBiT-seq: deterministic-barcoding-in-tissue using two orthogonal sets of barcoded reagent flows through PDMS microfluidic channels pressed onto tissue, defining a 50 × 50 grid of 50 µm × 50 µm spatial barcodes. Anticipates: PDMS-microchannel-defined spatial barcoding architecture as alternative to spotted-array (Visium) and random-bead (Slide-seq) approaches.
“Cell 2020, 183, 1665–1681.e18”
written · p. 1 · 2020-01-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
43Liu 2002 nanoliter rotary device for polymerase chain reaction (Stephen R. Quake group, Caltech, 2002-06-01): Discloses the rotary PCR architecture: a closed-loop nanoliter channel in PDMS with three integrated peristaltic Quake (MLSI) micropumps that convect the reaction mixture around a circuit passing three fixed-temperature zones - thermal cycling in the spatial domain at constant heater temperatures, avoiding the thermal mass and ramp limits of cycling the whole chip. An
“Electrophoresis 2002, 23, 1531-1536”
written · p. 1 · 2002-01-01 · open
Macosko, McCarroll lab, Broad Institute · openie_prior_art · en
44Drop-seq single-cell RNA sequencing (Macosko, McCarroll lab, Broad Institute, 2015): Anticipates: co-encapsulation of single cells with barcoded beads in droplets via flow-focusing, lysis-on-bead chemistry, downstream pooled sequencing with barcode demultiplexing. Together with InDrops (Klein et al. 2015), this is the technical foundation of the modern single-cell genomics ecosystem, including the commercial 10x Genomics Chromium platform.
“Cell 2015, 161, 1202–1214”
written · p. 1 · 2015-01-01 · open
Marc J. Madou · openie_prior_art · en
45Madou 2011 — Fundamentals of Microfabrication and Nanotechnology (3rd ed, 3-volume) (textbook) (Marc J. Madou, 2011-08-01): Three-volume engineering reference covering MEMS and microfluidic fabrication: photolithography, soft-lithography, hot embossing, injection molding, LIGA, deep RIE, glass etching, bonding (anodic, fusion, thermocompression, plasma), and integration. Volume III specifically covers manufacturing techniques for microfluidics. Anticipates: any patent on a 'm
“ISBN 978-0849331800”
written · p. 1 · 2011-01-01 · open
Stephen R. Quake group, Stanford / Caltech · openie_prior_art · en
46Maerkl and Quake 2007 systems approach to measuring transcription-factor binding energy landscapes (MITOMI) (Stephen R. Quake group, Stanford / Caltech, 2007-01-12): Discloses the MITOMI architecture: a dense array of PDMS unit cells where a circular button membrane valve is lowered onto a functionalized surface to mechanically trap surface-bound molecular complexes at the instant of measurement, defeating dissociation during washing and enabling thousands of true equilibrium
“Science 2007, 315, 233-237”
written · p. 1 · 2007-01-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
47Marcus 2006 microfluidic single-cell mRNA isolation and analysis (Stephen R. Quake group, Caltech, 2006-05-01): An early end-to-end single-cell mRNA sample-preparation chip: a multilayer PDMS device that captures one cell in an isolated nanoliter chamber, lyses it, captures the released mRNA on an oligo-dT affinity bead column, washes, and reverse-transcribes / elutes cDNA for downstream qPCR - all with monolithic membrane valves and dead-volume-controlled metering. Anticipat
“Anal. Chem. 2006, 78, 3084-3089”
written · p. 1 · 2006-01-01 · open
McDonald, Whitesides (Harvard) · openie_prior_art · en
48Poly(dimethylsiloxane) as a material for fabricating microfluidic devices (McDonald & Whitesides 2002) (McDonald, Whitesides (Harvard), 2002): The canonical methodology paper for PDMS as a microfluidic substrate: physical properties, surface chemistry, plasma activation, design constraints. Cited as the standard methodological reference for any PDMS-based microfluidic device. Companion to Duffy 1998 (the originating disclosure) and Xia/Whitesides 1998 (the broader soft-lithog
“Acc. Chem. Res. 2002, 35, 491–499”
written · p. 1 · 2002-01-01 · open
Stephen R. Quake group, Stanford · openie_prior_art · en
49Melin and Quake 2007 microfluidic large-scale integration: evolution of design rules for biological automation (Stephen R. Quake group, Stanford, 2007-06-01): The review that explicitly frames microfluidic large-scale integration as having design rules analogous to VLSI: minimum valve dimensions, multiplexer fan-out limits, channel-rounding requirements, push-up vs push-down valve choices, manifold pressure budgets, and the composition rules for assembling valves into pumps,
“Annu. Rev. Biophys. Biomol. Struct. 2007, 36, 213-231”
written · p. 1 · 2007-01-01 · open
Cullis, Hansen labs (UBC) · openie_prior_art · en
50Microfluidic mRNA-LNP vaccine formulation (Cullis, Hansen labs (UBC), 2012): Foundational disclosure of microfluidic LNP (lipid nanoparticle) formulation for nucleic acid delivery: rapid mixing of lipid-in-ethanol with nucleic-acid-in-aqueous in microfluidic herringbone mixer drives spontaneous LNP self-assembly with sub-100 nm size distribution. Architecturally critical: the Pfizer-BioNTech and Moderna COVID-19 vaccines depend on Precision Nanosystems' microfluidic LNP manuf
“Mol. Ther. Nucleic Acids 2012, 1, e37”
written · p. 1 · 2012-01-01 · open