← concepts · the commons
pump-membrane-pneumatic
36 moment(s) that assert this concept — showing 1–36 of 36
moderateTwo independent sources — corroborated, but not broadly
↣ how this spread over time →reuse terms across this evidence: 36 openly licensed
scholarly papers (2)
Peter Gravesen; Jens Branebjerg; Ole Sondergaard Jensen · openie_prior_art · en
1Gravesen 1993 — Microfluidics Review (Peter Gravesen; Jens Branebjerg; Ole Sondergaard Jensen, 1993): Gravesen 1993 is one of the first explicit uses of 'microfluidics' as a field designator. Catalogs the state of the art in 1993: silicon piezoelectric pumps (van Lintel 1988, Esashi 1988-90), silicon membrane valves, silicon flow sensors, and silicon micromixers. Anticipates: (a) any post-1993 patent claim that recites a generic 'microfluidic system comprising pump, valve, mi
“J. Micromech. Microeng. 3, 168 (1993) doi:10.1088/0960-1317/3/4/002”
written · p. 1 · 1993-01-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
2Hansen 2002 robust scalable microfluidic metering for protein crystallization by free interface diffusion (Stephen R. Quake group, Caltech, 2002-12-24): Discloses the microfluidic metering method underlying chip-format protein crystallization: paired nanoliter chambers loaded by dead-end filling, isolated by monolithic membrane valves, then connected through an interface valve so the two reagents mix only by free-interface diffusion - reproducibly sampling a crystallization t
“Proc. Natl. Acad. Sci. U.S.A. 2002, 99, 16531-16536”
written · p. 1 · 2002-01-01 · open
Chih-Ming Ho; Yu-Chong Tai · openie_prior_art · en
3Ho & Tai 1998 - Micro-electro-mechanical-systems (MEMS) and fluid flows (Chih-Ming Ho; Yu-Chong Tai, 1998): Ho-Tai 1998 is the canonical Annual Review of Fluid Mechanics survey of MEMS-based microfluidics as of the late 1990s. Catalogs pre-2000 micro-pumps, micro-valves, micro-channels, micro-mixers, and micro-flow sensors - establishing all these subsystems as prior art before 2000. Particularly load-bearing for invalidating broad post-2000 micro-pump/micro-valve patents.
“Annu. Rev. Fluid Mech. 30, 579 (1998)”
written · p. 1 · 1998-01-01 · open
Hoiman et al. (Helsinki MEMS group) · openie_prior_art · en
4Hoiman 1986 - Silicon micropump (Helsinki) (Hoiman et al. (Helsinki MEMS group), 1986): Pre-1990 silicon-micromachined membrane micropump from the Helsinki MEMS effort. Discloses bulk-silicon micropump topology - membrane-driven displacement chamber with bonded check-valves. Combined with Esashi 1989 (already in corpus) and the slightly later Smits 1990 piezoelectric pump literature, Hoiman 1986 establishes the silicon-MEMS micropump as established prior art well before 1990.
“Helsinki MEMS proceedings (1986)”
written · p. 1 · 1986-01-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
5Marcus 2006 microfluidic single-cell mRNA isolation and analysis (Stephen R. Quake group, Caltech, 2006-05-01): An early end-to-end single-cell mRNA sample-preparation chip: a multilayer PDMS device that captures one cell in an isolated nanoliter chamber, lyses it, captures the released mRNA on an oligo-dT affinity bead column, washes, and reverse-transcribes / elutes cDNA for downstream qPCR - all with monolithic membrane valves and dead-volume-controlled metering. Anticipat
“Anal. Chem. 2006, 78, 3084-3089”
written · p. 1 · 2006-01-01 · open
California Institute of Technology (Stephen Quake et al.) · openie_prior_art · en
6Quake Lab MLSI Monolithic Membrane Valve Patent Family (California Institute of Technology (Stephen Quake et al.), 2000-04-07): Caltech/Quake monolithic-membrane valve patent family. Anchors claims around: (a) two-layer PDMS device in which a flow channel is occluded by deflection of a thin elastomeric membrane via pressurization of an orthogonal control channel; (b) push-down geometry where the control channel sits above the flow channel; (c) push-up geometry where the contr
“US6408878B2 grant text USPTO”
written · p. 1 · 2000-01-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
7Studer 2004 scaling properties of a low-actuation-pressure microfluidic valve (Stephen R. Quake group, Caltech, 2004-01-01): Establishes the quantitative design rules for monolithic-membrane (Quake/MLSI) microvalves and introduces the push-up valve geometry that achieves valve closure at sub-1-psi actuation pressures. Discloses: the mechanical model (membrane bending, contact mechanics) relating closure pressure to membrane thickness and channel width; the push-up vs push-dow
“J. Appl. Phys. 2004, 95, 393-398”
written · p. 1 · 2004-01-01 · open
Stephen Quake group, Caltech · openie_prior_art · en
8Quake monolithic pneumatic membrane valve and pump (Stephen Quake group, Caltech, 2000): Foundational disclosure of pneumatically actuated elastomeric membrane valves built monolithically into a multilayer PDMS chip. By cyclically actuating three valves in series, a peristaltic pump is realized. This is the architectural ancestor of essentially every subsequent on-chip pneumatic valve and pump. Anticipates: pneumatic membrane valve (control channel + thin membrane + flow chan
“Science 2000, 288, 113–116”
written · p. 1 · 2000-01-01 · open
Roland Zengerle and coworkers, University of the German Armed Forces / IMM Mainz · openie_prior_art · en
9A bidirectional silicon micropump (Zengerle, Richter, Sandmaier, 1992) (Roland Zengerle and coworkers, University of the German Armed Forces / IMM Mainz, 1992): An electrostatically actuated silicon membrane micropump whose direction of net flow can be reversed by changing the actuation frequency, exploiting the frequency-dependent dynamics of its two passive flap check valves (above the resonance of one valve the pump runs forward, in a band between the two valve resonances
“Zengerle, R.; Richter, A.; Sandmaier, H. MEMS 1992, pp. 19-24”
written · p. 1 · 1992-01-01 · open
3M Drug Delivery Systems (now Solventum) · openie_prior_art · en
103M / Solventum Hollow Microstructured Transdermal System (hMTS) (3M Drug Delivery Systems (now Solventum)): 3M / Solventum Hollow Microstructured Transdermal System (hMTS) [Subsystems: pump-membrane-pneumatic, fabrication-thermoplastic-injection-molding, interface-luer-lock-port, interface-blister-pack-reagent-storage; CPC: A61M 37/0015, A61M 5/142]
“Burton SA et al. Pharm Res 28(1):31-40 2011 doi:10.1007/s11095-010-0177-8; 3M Drug Delivery Systems patent family”
written · p. 1 · 2026-05-01 · open
Berlin Heart GmbH · openie_prior_art · en
11Berlin Heart EXCOR Pediatric Pulsatile VAD (Berlin Heart GmbH): Berlin Heart EXCOR Pediatric Pulsatile VAD [Subsystems: pump-membrane-pneumatic, valve-check; CPC: A61M 60/13, A61M 60/422]
“Hetzer R, Loebe M, Potapov EV, Weng Y, Stiller B, Hennig E, Alexi-Meskishvili V, Lange PE. Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children. Ann Thorac Surg 1998; Berlin Heart EXCOR Pediatri”
written · p. 1 · 2026-05-01 · open
Ronald D. Moore · openie_prior_art · en
12Battlestar Galactica Cylon Centurion organic-fluid circulation system (Ronald D. Moore): Battlestar Galactica Cylon Centurion organic-fluid circulation system [Subsystems: pump-membrane-pneumatic, interface-luer-lock-port; CPC: ]
“Battlestar Galactica miniseries (Sci Fi 2003); Caprica (2010) shows Centurion construction.”
written · p. 1 · 2026-05-01 · open
Carmat SA (Alain Carpentier / Matra / Matra Defense) · openie_prior_art · en
13Carmat Aeson Bioprosthetic Total Artificial Heart (Carmat SA (Alain Carpentier / Matra / Matra Defense)): Carmat Aeson Bioprosthetic Total Artificial Heart [Subsystems: pump-membrane-pneumatic, valve-check; CPC: A61M 60/13, A61M 60/178, A61M 60/187]
“Carpentier A, Latremouille C, Cholley B, Smadja DM, Roussel JC, Boissier E, Trochu JN, Gueffet JP, Treillot M, Bizouarn P, Mejean S, Naghavi M, Carpentier S, Jansen P. First clinical use of a bioprosthetic total artificial heart: report of ”
written · p. 1 · 2026-05-01 · open
DnaNudge Ltd. (Imperial College London spin-out) · openie_prior_art · en
14DnaNudge / NudgeBox Rapid Cartridge PCR System (DnaNudge Ltd. (Imperial College London spin-out)): DnaNudge / NudgeBox Rapid Cartridge PCR System [Subsystems: pump-membrane-pneumatic, thermal-pcr-cycling, detection-fluorescence-on-chip, fabrication-thermoplastic-injection-molding, interface-blister-pack-reagent-storage, architecture-stat-test-cartridge; CPC: B01L 3/5027, C12Q 1/686]
“Gibani MM et al. Lancet Microbe 1(7):e300-e307 2020 doi:10.1016/S2666-5247(20)30121-X (CovidNudge clinical evaluation); UK MHRA authorization”
written · p. 1 · 2026-05-01 · open
Frank Herbert · openie_prior_art · en
15Dune stillsuit body-fluid reclamation (Frank Herbert original 1965) (Frank Herbert): Dune stillsuit body-fluid reclamation (Frank Herbert original 1965) [Subsystems: pump-membrane-pneumatic, pump-capillary-passive, separation-membrane-filtration-on-chip, interface-luer-lock-port; CPC: ]
“Frank Herbert, Dune (Chilton 1965) ISBN 0-441-17266-0; pages 110-112 'Manual of Muad'dib' detailing stillsuit construction.”
written · p. 1 · 1965-01-01 · open
Posthuman Studios · openie_prior_art · en
16Eclipse Phase synthmorph internal fluid-skeleton and lubricant systems (Posthuman Studios): Eclipse Phase synthmorph internal fluid-skeleton and lubricant systems [Subsystems: thermal-microchannel-cooling-electronics, pump-membrane-pneumatic; CPC: ]
“Eclipse Phase core rulebook (Posthuman Studios 2009); Transhuman sourcebook.”
written · p. 1 · 2026-05-01 · open
Formulatrix · openie_prior_art · en
17Formulatrix Mantis and Tempest nanoliter dispensers (Formulatrix): Formulatrix Mantis and Tempest nanoliter dispensers [Subsystems: valve-quake-pneumatic-membrane, pump-membrane-pneumatic, fabrication-thermoplastic-injection-molding; CPC: B01L 3/00, B01L 3/02]
“Formulatrix Mantis liquid handler product literature. https://formulatrix.com/liquid-handling-systems/mantis-liquid-handler/. Tempest launch ~2017.”
written · p. 1 · 2026-05-01 · open
Peter Gravesen; Jens Branebjerg; Ole Sondergaard Jensen · openie_prior_art · en
18Gravesen 1993 — Microfluidics Review (Peter Gravesen; Jens Branebjerg; Ole Sondergaard Jensen): Gravesen 1993 — Microfluidics Review [Subsystems: pump-piezoelectric-disc, pump-membrane-pneumatic, valve-doormat-style, fabrication-silicon-koh-etching; CPC: B81C 1/00, B01L 3/502]
“Gravesen, P., Branebjerg, J., Jensen, O. S. (1993). 'Microfluidics — a review.' Journal of Micromechanics and Microengineering 3(4): 168-182. doi:10.1088/0960-1317/3/4/002”
written · p. 1 · 1993-01-01 · open
Bungie / 343 Industries / Microsoft / Eric Nylund · openie_prior_art · en
19Halo MJOLNIR armor biofoam emergency wound-sealant injector (Bungie / 343 Industries / Microsoft / Eric Nylund): Halo MJOLNIR armor biofoam emergency wound-sealant injector [Subsystems: pump-membrane-pneumatic, valve-burst-frangible, interface-blister-pack-reagent-storage, architecture-stat-test-cartridge; CPC: ]
“Halo: Combat Evolved (Bungie/Microsoft, 2001); detailed in Halo: The Fall of Reach (Eric Nylund, Del Rey ISBN 978-0-345-45132-3, 2001) and Halo: First Strike (Eric Nylund, 2003).”
written · p. 1 · 2026-05-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
20Hansen 2002 robust scalable microfluidic metering for protein crystallization by free interface diffusion (Stephen R. Quake group, Caltech): Hansen 2002 robust scalable microfluidic metering for protein crystallization by free interface diffusion [Subsystems: fabrication-pdms-soft-lithography, valve-quake-pneumatic-membrane, pump-membrane-pneumatic, architecture-multiplex-cartridge; CPC: B01L 3/00, C30B 7/00, C30B 29/58, B01L 7/00]
“Hansen, C. L.; Skordalakes, E.; Berger, J. M.; Quake, S. R. A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion. Proc. Natl. Acad. Sci. U.S.A. 2002, 99, 16531-16536. DOI: 10.1073”
written · p. 1 · 2002-01-01 · open
Chih-Ming Ho; Yu-Chong Tai · openie_prior_art · en
21Ho & Tai 1998 - Micro-electro-mechanical-systems (MEMS) and fluid flows (Chih-Ming Ho; Yu-Chong Tai): Ho & Tai 1998 - Micro-electro-mechanical-systems (MEMS) and fluid flows [Subsystems: pump-membrane-pneumatic, pump-piezoelectric-disc, valve-check, fabrication-silicon-drie, fabrication-silicon-koh-etching; CPC: B01L 3/502, F04B 19/00]
“Ho, C.-M., Tai, Y.-C. (1998). 'Micro-electro-mechanical-systems (MEMS) and fluid flows.' Annu. Rev. Fluid Mech. 30: 579-612. doi:10.1146/annurev.fluid.30.1.579”
written · p. 1 · 1998-01-01 · open
Hoiman et al. (Helsinki MEMS group) · openie_prior_art · en
22Hoiman 1986 - Silicon micropump (Helsinki) (Hoiman et al. (Helsinki MEMS group)): Hoiman 1986 - Silicon micropump (Helsinki) [Subsystems: pump-membrane-pneumatic, pump-piezoelectric-disc, fabrication-silicon-koh-etching, valve-check; CPC: F04B 19/00, B01L 3/502]
“Hoiman et al. (1986). 'A silicon-based micropump.' Sensors and Actuators (proceedings of Helsinki MEMS work, 1986).”
written · p. 1 · 1986-01-01 · open
Matt Fraction / Salvador Larroca / Marvel · openie_prior_art · en
23Iron Man Bleeding Edge armor (subdermal nanofluidic suit storage) (Matt Fraction / Salvador Larroca / Marvel): Iron Man Bleeding Edge armor (subdermal nanofluidic suit storage) [Subsystems: pump-membrane-pneumatic, interface-blister-pack-reagent-storage; CPC: ]
“Invincible Iron Man #25 (Marvel December 2010), Matt Fraction & Salvador Larroca; Endo-Sym armor variant in Superior Iron Man (2014).”
written · p. 1 · 2026-05-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
24Marcus 2006 microfluidic single-cell mRNA isolation and analysis (Stephen R. Quake group, Caltech): Marcus 2006 microfluidic single-cell mRNA isolation and analysis [Subsystems: fabrication-pdms-soft-lithography, valve-quake-pneumatic-membrane, pump-membrane-pneumatic, cell-trap-hydrodynamic, cell-poration-mechanical-shear, separation-affinity-capture; CPC: B01L 3/00, C12N 15/10, C12Q 1/6806, B01L 7/00]
“Marcus, J. S.; Anderson, W. F.; Quake, S. R. Microfluidic single-cell mRNA isolation and analysis. Anal. Chem. 2006, 78, 3084-3089. DOI: 10.1021/ac0519460”
written · p. 1 · 2006-01-01 · open
PowerVision Inc. (acquired by Alcon) · openie_prior_art · en
25FluidVision Accommodating Intraocular Lens (PowerVision / Alcon) (PowerVision Inc. (acquired by Alcon)): FluidVision Accommodating Intraocular Lens (PowerVision / Alcon) [Subsystems: pump-membrane-pneumatic, interface-o-ring-seal; CPC: A61F 2/1635, A61F 2/1648]
“PowerVision Inc. patent family; FluidVision presented at ASCRS; PowerVision acquired by Alcon 2019.”
written · p. 1 · 2026-05-01 · open
California Institute of Technology (Stephen Quake et al.) · openie_prior_art · en
26Quake Lab MLSI Monolithic Membrane Valve Patent Family (California Institute of Technology (Stephen Quake et al.)): Quake Lab MLSI Monolithic Membrane Valve Patent Family [Subsystems: valve-quake-pneumatic-membrane, pump-membrane-pneumatic, fabrication-pdms-soft-lithography, fabrication-pdms-replica-molding, material-pdms-base; CPC: F16K 99/0019, B01L 3/502738]
“US6408878 priority 2000-04-07; US6929030; US7144616; US7704698; US7837946 (Caltech)”
written · p. 1 · 2026-05-01 · open
Replenish Inc. (USC Doheny / Meng spin-out) · openie_prior_art · en
27Replenish Inc. Ophthalmic MEMS Drug Delivery Micropump (Replenish Inc. (USC Doheny / Meng spin-out)): Replenish Inc. Ophthalmic MEMS Drug Delivery Micropump [Subsystems: pump-membrane-pneumatic, valve-check, interface-blister-pack-reagent-storage, material-pdms-base; CPC: A61M 5/14276, A61F 9/0017]
“Lo R, Li PY, Saati S, Agrawal RN, Humayun MS, Meng E Biomed Microdevices 11(5):959-970 2009 doi:10.1007/s10544-009-9313-9”
written · p. 1 · 2026-05-01 · open
Repligen Corporation (formerly Spectrum Laboratories) · openie_prior_art · en
28Repligen KrosFlo tangential flow filtration system (Repligen Corporation (formerly Spectrum Laboratories)): Repligen KrosFlo tangential flow filtration system [Subsystems: separation-membrane-filtration-on-chip, pump-membrane-pneumatic; CPC: B01D 61/14, B01D 61/22]
“Spectrum Laboratories (acquired by Repligen 2017) KrosFlo line. https://www.repligen.com/products/krosflo. Patent family: US8231788B2 (Spectrum Laboratories; priority 2007).”
written · p. 1 · 2026-05-01 · open
Repligen Corporation (formerly Refine Technology) · openie_prior_art · en
29Repligen XCell ATF alternating tangential flow cell-retention device (Repligen Corporation (formerly Refine Technology)): Repligen XCell ATF alternating tangential flow cell-retention device [Subsystems: separation-membrane-filtration-on-chip, pump-membrane-pneumatic, cell-organoid-perfusion; CPC: B01D 61/22, C12M 1/12, C12M 29/04]
“Refine Technology (acquired by Repligen 2014) ATF system commercialized 2002. Original patent: US6544424B1 (Shevitz, J.; Refine Technology; priority 1999).”
written · p. 1 · 2026-05-01 · open
Roche Diagnostics · openie_prior_art · en
30Roche cobas Liat Strep A cartridge (Roche Diagnostics): Roche cobas Liat Strep A cartridge [Subsystems: thermal-pcr-cycling, detection-fluorescence-on-chip, pump-membrane-pneumatic; CPC: B01L 7/52, C12Q 1/689]
“Roche cobas Liat Strep A 510(k) clearance 2018.”
written · p. 1 · 2026-05-01 · open
Stephen R. Quake group, Caltech · openie_prior_art · en
31Studer 2004 scaling properties of a low-actuation-pressure microfluidic valve (Stephen R. Quake group, Caltech): Studer 2004 scaling properties of a low-actuation-pressure microfluidic valve [Subsystems: fabrication-pdms-soft-lithography, valve-quake-pneumatic-membrane, pump-membrane-pneumatic, interface-pressure-manifold; CPC: F16K 99/00, B01L 3/00, F15C 5/00]
“Studer, V.; Hang, G.; Pandolfi, A.; Ortiz, M.; Anderson, W. F.; Quake, S. R. Scaling properties of a low-actuation-pressure microfluidic valve. J. Appl. Phys. 2004, 95, 393-398. DOI: 10.1063/1.1629781”
written · p. 1 · 2004-01-01 · open
SynCardia Systems LLC (Jarvik-7 lineage from Utah / Robert Jarvik / Willem Kolff) · openie_prior_art · en
32SynCardia temporary Total Artificial Heart (Jarvik-7 lineage) (SynCardia Systems LLC (Jarvik-7 lineage from Utah / Robert Jarvik / Willem Kolff)): SynCardia temporary Total Artificial Heart (Jarvik-7 lineage) [Subsystems: pump-membrane-pneumatic, valve-check, valve-doormat-style; CPC: A61M 60/13, A61M 60/187]
“DeVries WC, Anderson JL, Joyce LD, Anderson FL, Hammond EH, Jarvik RK, Kolff WJ. Clinical use of the total artificial heart. NEJM 1984; SynCardia TAH FDA PMA P030011 (2004); Freedom Driver portable pneumatic controller.”
written · p. 1 · 2026-05-01 · open
TissUse GmbH (TU Berlin / Uwe Marx) · openie_prior_art · en
33TissUse HUMIMIC Multi-Organ Chip Platform (TissUse GmbH (TU Berlin / Uwe Marx)): TissUse HUMIMIC Multi-Organ Chip Platform [Subsystems: architecture-body-on-chip-coupled-organs, pump-peristaltic-on-chip, pump-membrane-pneumatic, cell-organoid-perfusion; CPC: C12M 23/16, C12M 29/10]
“Wagner I, Materne EM, Brincker S, Sussbier U, Fradrich C, Busek M, Sonntag F, Sakharov DA, Trushkin EV, Tonevitsky AG, Lauster R, Marx U. A dynamic multi-organ-chip for long-term cultivation and substance testing proven by 3D human liver an”
written · p. 1 · 2026-05-01 · open
Stephen Quake group, Caltech · openie_prior_art · en
34Quake monolithic pneumatic membrane valve and pump (Stephen Quake group, Caltech): Quake monolithic pneumatic membrane valve and pump [Subsystems: valve-quake-pneumatic-membrane, pump-membrane-pneumatic, pump-peristaltic-on-chip, fabrication-pdms-soft-lithography, fabrication-multilayer-lamination; CPC: F16K 99/00, B01L 3/00]
“Unger, M. A.; Chou, H.-P.; Thorsen, T.; Scherer, A.; Quake, S. R. Monolithic microfabricated valves and pumps by multilayer soft lithography. Science 2000, 288, 113–116. DOI: 10.1126/science.288.5463.113”
written · p. 1 · 2026-05-01 · open
Visby Medical, Inc. · openie_prior_art · en
35Visby Medical STI 2024 cartridge extend (Visby Medical, Inc.): Visby Medical STI 2024 cartridge extend [Subsystems: thermal-pcr-cycling, detection-fluorescence-on-chip, pump-membrane-pneumatic; CPC: B01L 7/52, C12Q 1/6886]
“Visby Medical 4-plex STI cartridge FDA clearance announcement Q1 2024.”
written · p. 1 · 2024-01-01 · open
Roland Zengerle and coworkers, University of the German Armed Forces / IMM Mainz · openie_prior_art · en
36A bidirectional silicon micropump (Zengerle, Richter, Sandmaier, 1992) (Roland Zengerle and coworkers, University of the German Armed Forces / IMM Mainz): A bidirectional silicon micropump (Zengerle, Richter, Sandmaier, 1992) [Subsystems: fabrication-silicon-koh-etching, pump-membrane-pneumatic, valve-check, pump-solenoid-displacement; CPC: F04B 43/04, B01L 3/00, A61M 5/142]
“Zengerle, R.; Richter, A.; Sandmaier, H. A micro membrane pump with electrostatic actuation. Proc. IEEE Micro Electro Mechanical Systems (MEMS 1992), Travemunde, 1992, pp. 19-24. Zengerle, R.; Ulrich, J.; Kluge, S.; Richter, M.; Richter, A.”
written · p. 1 · 1992-01-01 · open