← concepts · the commons
separation-deterministic-lateral-displacement
6 moment(s) that assert this concept — showing 1–6 of 6
moderateTwo independent sources — corroborated, but not broadly
↣ how this spread over time →reuse terms across this evidence: 6 openly licensed
scholarly papers (3)
Huang, Sturm, Austin, Cox (Princeton) · openie_prior_art · en
1Deterministic lateral displacement particle separation (Huang, Sturm, Austin, Cox (Princeton), 2004): Disclosed deterministic lateral displacement: a periodic pillar array shifts particles above a critical size laterally with each row, while smaller particles pass through. Anticipates the entire DLD field including blood cell separation, CTC capture, and exosome isolation. Subsequent commercial implementations (e.g., GPB Scientific) build directly on this geometry.
“Science 2004, 304, 987–990”
written · p. 1 · 2004-01-01 · open
Various — Kersaudy-Kerhoas (Heriot-Watt), Toner group, Lim group (Singapore) · openie_prior_art · en
2Microfluidic extracellular vesicle / exosome isolation (Various — Kersaudy-Kerhoas (Heriot-Watt), Toner group, Lim group (Singapore), 2014): Composite reference for the microfluidic exosome / EV isolation subfield. Combines size-based (DLD adapted for sub-200-nm cutoff), affinity-based (immunomagnetic), and electrokinetic (DEP) strategies. Anticipates: clinical-grade microfluidic exosome isolation for liquid biopsy applications. Underlies commercial efforts by Exosome Diagnos
“Lab Chip 2015, 15, 2388–2394”
written · p. 1 · 2014-01-01 · open
Huang, Sturm, Austin, Cox (Princeton) · openie_prior_art · en
3Deterministic lateral displacement particle separation (Huang, Sturm, Austin, Cox (Princeton)): Deterministic lateral displacement particle separation [Subsystems: separation-deterministic-lateral-displacement, fabrication-silicon-drie; CPC: B03B 5/00, B01L 3/00]
“Huang, L. R.; Cox, E. C.; Austin, R. H.; Sturm, J. C. Continuous particle separation through deterministic lateral displacement. Science 2004, 304, 987–990. DOI: 10.1126/science.1094567”
written · p. 1 · 2026-05-01 · open
Various — Kersaudy-Kerhoas (Heriot-Watt), Toner group, Lim group (Singapore) · openie_prior_art · en
4Microfluidic extracellular vesicle / exosome isolation (Various — Kersaudy-Kerhoas (Heriot-Watt), Toner group, Lim group (Singapore)): Microfluidic extracellular vesicle / exosome isolation [Subsystems: separation-deterministic-lateral-displacement, separation-magnetophoresis, separation-dielectrophoresis, fabrication-pdms-soft-lithography; CPC: B01L 3/00, G01N 33/49]
“Liga, A.; Vliegenthart, A. D. B.; Oosthuyzen, W.; Dear, J. W.; Kersaudy-Kerhoas, M. Exosome isolation: a microfluidic road-map. Lab Chip 2015, 15, 2388–2394. DOI: 10.1039/C5LC00240K”
written · p. 1 · 2026-05-01 · open
OpenIE Microfluidics Commons · openie_microfluidics_cad · en
5DLD (deterministic lateral displacement) reference array, 5 µm cutoff: Hexagonal post array with 10 µm post diameter, 6 µm gap, 1/10 row shift fraction over 50 mm length; cutoff diameter ~5 µm; 8-row design giving 4× lateral displacement of large particles
“Hexagonal post array with 10 µm post diameter, 6 µm gap, 1/10 row shift fraction over 50 mm length; cutoff diameter ~5 µm; 8-row design giving 4× lateral displacement of large particles”
written · p. 1 · 2026-05-09 · open
OpenIE Microfluidics Commons · openie_microfluidics_cad · en
6Exosome separation DLD chip (sub-200 nm cutoff): Hexagonal post array with 500 nm post diameter, 100 nm gap, 1/20 row shift fraction over 20 mm length. Cutoff diameter ~80 nm (within exosome size range, 30–150 nm). Sample inlet, buffer-sheath inlet, and four size-fractionated outlets for size-based exosome enrichment from biological fluids.
“Hexagonal post array with 500 nm post diameter, 100 nm gap, 1/20 row shift fraction over 20 mm length. Cutoff diameter ~80 nm (within exosome size range, 30–150 nm). Sample inlet, buffer-sheath inlet, and four size-fractionated outlets for ”
written · p. 1 · 2026-05-09 · open