pump-capillary-passive

128 moment(s) that assert this concept — showing 1–50 of 128

moderateTwo independent sources — corroborated, but not broadly
↣ how this spread over time →

reuse terms across this evidence: 50 openly licensed

provenance — click a node to open its encoding unit
[1] Parlak[2] David[3] Lorand[4] Raphael[5] Henry[6] Whitesides[7] Javey[8] Roland[9] NASA[10] John[11] Richard[12] Carlo
showing 12 of 128 moments
scholarly papers (3)
Parlak O, Salleo A et al. (Stanford) · openie_prior_art · en
1AfaSci-style Wearable Cortisol Sensor (sweat cortisol aptamer wearable, multi-author) (Parlak O, Salleo A et al. (Stanford), 2018-06-25): Academic prior-art entry covering the wearable-cortisol-patch class. Discloses sweat-collecting wearable patch with molecularly imprinted polymer recognition layer and electrochemical readout for cortisol. Anticipates: wearable hormone sensing architectures combining a microfluidic sweat-collection layer with affinity-functionalized electro
“Parlak O et al. Sci Adv 2018 doi:10.1126/sciadv.aar2904”
written · p. 1 · 2018-01-01 · open
David J. Beebe group, University of Wisconsin-Madison · openie_prior_art · en
2Berthier and Beebe 2007 flow rate analysis of a surface-tension-driven passive micropump (David J. Beebe group, University of Wisconsin-Madison, 2007-10-08): Provides the quantitative theory of surface-tension-driven passive pumping: placing a small drop on the inlet and a larger drop on the outlet of a microchannel creates a Laplace-pressure difference (smaller drop has higher internal pressure) that pumps fluid from small to large drop, with the paper deriving the flow-rate
“Lab Chip 2007, 7, 1475-1478”
written · p. 1 · 2007-01-01 · open
Lorand Eoetvoes (1886); Wilfrid Noel Bond (1928 dimensionless form) · openie_prior_art · en
3Bond / Eoetvoes Number Bo = rho g L^2 / gamma (Lorand Eoetvoes (1886); Wilfrid Noel Bond (1928 dimensionless form), 1886): Bond number explains why microfluidics works at all: at L ~ 100 microns, Bo ~ 10^-3 for water, so gravity is irrelevant and surface tension dominates. This is THE physical foundation for the microfluidic regime; anchors every patent claim that recites 'gravity-independent operation', 'orientation-independent chip', or 'surface-tension-driven liquid handli
“Eoetvoes, R. Ann. Phys. 263, 448 (1886)”
written · p. 1 · 1886-01-01 · open
Raphael Consden, Archer Gordon, Archer Martin (Wool Industries Research Association / Lister Institu · openie_prior_art · en
4Paper partition chromatography (Raphael Consden, Archer Gordon, Archer Martin (Wool Industries Research Association / Lister Institute), 1944): The direct ancestor of paper microfluidics. Discloses capillary-wicking transport of sample through a cellulose paper matrix as the engine of an analytical separation, including two-dimensional development. Anticipates: passive capillary-driven flow in paper as a microfluidic transport mechanism, paper as a substrate for multi-step an
“Biochem. J. 1944, 38, 224-232”
written · p. 1 · 1944-01-01 · open
Henry Darcy · openie_prior_art · en
5Darcy 1856 - Les Fontaines Publiques de la Ville de Dijon (Darcy's law) (Henry Darcy, 1856): Discloses Darcy's law: flux through a porous medium is proportional to the pressure gradient divided by viscosity, with a material-dependent permeability constant. Load-bearing for all paper microfluidic modeling (Whitesides uPADs, lateral flow assays, blood-separation paper devices), sintered-frit and porous-membrane flow control on chip, packed-bed micro-reactors and on-chip chromat
“Darcy, Les Fontaines Publiques de la Ville de Dijon (1856)”
written · p. 1 · 1856-01-01 · open
Whitesides group, Harvard · openie_prior_art · en
6Wax-printed paper microfluidics for low-cost diagnostics (Whitesides group, Harvard, 2009): Disclosed wax printing as a sub-$0.10/device fabrication path for paper microfluidics: a commodity solid-ink printer deposits wax patterns that, after melting, reflow vertically through paper to create hydrophobic barriers defining channels. Anticipates: wax-as-hydrophobic-barrier as a paper microfluidic fabrication primitive, low-cost disposable diagnostic manufacturing without specia
“Anal. Chem. 2009, 81, 7091–7095”
written · p. 1 · 2009-01-01 · open
Javey group, UC Berkeley · openie_prior_art · en
7Wearable sweat sensors with multiplexed biosensing (Javey group, UC Berkeley, 2016): Foundational disclosure of fully integrated wearable sweat sensor: flexible PCB with multiple ion-selective electrodes, wireless transmission, and integrated microfluidic-equivalent sweat-collection layer. Anticipates: skin-conformal microfluidic sensor architecture, real-time multiplexed sweat metabolite monitoring, and the entire wearable-microfluidic-biosensor commercial category subsequen
“Nature 2016, 529, 509–514”
written · p. 1 · 2016-01-01 · open
Roland Zengerle group, IMTEK, University of Freiburg / HSG-IMIT · openie_prior_art · en
8Haeberle and Zengerle 2007 microfluidic platforms for lab-on-a-chip applications (Roland Zengerle group, IMTEK, University of Freiburg / HSG-IMIT, 2007-08-08): The Lab on a Chip review that organized the field into microfluidic platforms by liquid-propulsion principle - capillary, pressure-driven, centrifugal (lab-on-a-disc), electrokinetic, droplet/segmented-flow, and electrowetting digital microfluidics - and compared them by the unit operations each supports and their stat
“Lab Chip 2007, 7, 1094-1110”
written · p. 1 · 2007-01-01 · open
NASA Marshall Space Flight Center / Charles River Laboratories (Endosafe-PTS) / University of Surrey · openie_prior_art · en
9ISS Lab-on-Chip Application Development Portable Test System (LOCAD-PTS) (NASA Marshall Space Flight Center / Charles River Laboratories (Endosafe-PTS) / University of Surrey, 2007): LOCAD-PTS is the spaceflight derivative of the Charles River Endosafe PTS handheld endotoxin tester. Microfluidic prior art disclosed: (a) the 4-channel parallel capillary-driven cartridge with lyophilized LAL/glucan-detection reagents and integrated optical absorbance window is itself prior art
“Maule J et al., Astrobiology 9:759 (2009)”
written · p. 1 · 2007-01-01 · open
John Rogers group (Northwestern / Illinois) · openie_prior_art · en
10Soft, skin-mounted epidermal microfluidic device for sweat collection and analysis (John Rogers group (Northwestern / Illinois), 2016): Disclosed soft skin-mounted epidermal microfluidic patch with networks of capillary-driven channels, color-changing reagent zones, and smartphone-based readout. Anticipates: PDMS-based skin-conformal microfluidic chip architecture, capillary-driven sweat collection and reservoir storage on body, colorimetric multiplexed analysis with smartpho
“Sci. Transl. Med. 2016, 8, 366ra165”
written · p. 1 · 2016-01-01 · open
Richard Lucas · openie_prior_art · en
11Lucas 1918 — Capillary Rise Dynamics (Richard Lucas, 1918): Discloses that the rise height of a wetting liquid in a capillary scales as the square root of time (h proportional to sqrt(gamma r cos(theta) t / mu)). This Lucas equation is the immediate prior art for: (a) all paper microfluidic / lateral-flow assay timing claims that recite a sqrt(t) wicking law; (b) self-priming microfluidic channels with predictable fill time; (c) wicking-pad reagent-storage cartridges. Togethe
“Kolloid-Z. 23, 15 (1918) doi:10.1007/BF01461107”
written · p. 1 · 1918-01-01 · open
Carlo Marangoni (1865); Scriven & Sternling (1960) · openie_prior_art · en
12Marangoni convection (thermocapillary and solutocapillary forms) (Carlo Marangoni (1865); Scriven & Sternling (1960), 1865): Companion entry to marangoni-1865-surface-tension-flow (already in corpus), focused on convective form: Marangoni convection. Anticipates thermocapillary-pump microfluidic patents, solutocapillary mixing claims in droplet-on-chip devices, evaporation-driven coffee-ring patterning on chip, Marangoni-driven droplet motion on hydrophilic gradient surfaces,
“Marangoni Pavia thesis (1865)”
written · p. 1 · 1865-01-01 · open
Whitesides group, Harvard · openie_prior_art · en
13Paper-based microfluidic devices for distributed point-of-care diagnostics (Whitesides group, Harvard, 2007): The paper that established paper-based microfluidic analytical devices (µPADs) as a category. Anticipates: hydrophobic patterning of cellulose paper to define fluid channels, capillary-driven flow without external pumps, multiplex colorimetric assays on a single paper substrate. The entire low-resource diagnostic paper-fluidics field descends from this disclosure.
“Angew. Chem. Int. Ed. 2007, 46, 1318–1320”
written · p. 1 · 2007-01-01 · open
Jang-Ung Park group (UNIST, S. Korea) · openie_prior_art · en
14Park 2018 Stretchable Glucose-Sensing Smart Contact Lens (Jang-Ung Park group (UNIST, S. Korea), 2018-01-24): Discloses a fully wireless, battery-free smart contact lens combining stretchable graphene tear-glucose electrodes with an embedded LED for direct optical user feedback. Anticipates: graphene-electrode contact-lens biosensors for tear analytes; on-lens visual feedback (vs. external readout) for ocular wearables; stretchable transparent electrode patterning on soft con
“Park J et al. Sci Adv 2018 doi:10.1126/sciadv.aap9841”
written · p. 1 · 2018-01-01 · open
Yetisen, Lowe (Cambridge) · openie_prior_art · en
15Color-changing diagnostic paper microfluidics (multiple groups) (Yetisen, Lowe (Cambridge), 2010): Comprehensive review of paper-based microfluidic POC diagnostics: wax printing, hydrophobic patterning, multi-zone reagent staging, smartphone-camera readout. Cited as the standard reference for the entire paper-microfluidic POC subfield post-2010. Methodological complement to Whitesides foundational work and the Carrilho 2009 wax-printing recipe.
“Lab Chip 2013, 13, 2210–2251”
written · p. 1 · 2010-01-01 · open
Georg Hermann Quincke · openie_prior_art · en
16Quincke 1859 - Capillary-rise observations on solid-liquid interfaces (Georg Hermann Quincke, 1859): Discloses a systematic experimental program measuring capillary rise heights and meniscus shapes against a range of solid surfaces and liquids, predating Lucas 1918 and Washburn 1921 by six decades. Anticipates paper microfluidic disclosures that recite 'wicking driven by surface tension into porous substrate', 'differential capillary rise rates by surface chemistry', or 'char
“Quincke, Ann. Phys. Chem. 105, 1-48 (1859)”
written · p. 1 · 1859-01-01 · open
Multiple academic groups (Donnelly lab Queen's Belfast; Prausnitz lab Georgia Tech) · openie_prior_art · en
17Microneedle Ocular Patch for Posterior-Segment Drug Delivery (Multiple academic groups (Donnelly lab Queen's Belfast; Prausnitz lab Georgia Tech), 2020): Discloses ocular microneedle patches as an alternative to intravitreal injection for delivering anti-VEGF, corticosteroid, and small-molecule therapeutics to the posterior eye. Hollow variants integrate microfluidic channels for active perfusion. Anticipates: ocular microneedle patches with integrated microfluidic perfusion;
“Thakur Singh RR et al. Acta Biomater 2020 doi:10.1016/j.actbio.2020.03.039”
written · p. 1 · 2020-01-01 · open
Edward W. Washburn · openie_prior_art · en
18Washburn 1921 — The Dynamics of Capillary Flow (Edward W. Washburn, 1921-03): Discloses the canonical Washburn equation governing capillary-driven liquid penetration into porous media and small-bore tubes. This is THE prior-art anchor for paper-based microfluidics: every commercial lateral-flow assay (pregnancy tests, COVID antigen tests, etc.) operates in the Washburn regime and any patent that claims 'control of assay timing by paper geometry and surface tension' or 'reagen
“Phys. Rev. 17, 273 (1921) doi:10.1103/PhysRev.17.273”
written · p. 1 · 1921-01-01 · open
Whitesides group, Harvard · openie_prior_art · en
19µPADs II / III: Systematic Whitesides disclosures (Whitesides group, Harvard, 2010): Systematic Whitesides-group disclosures extending µPAD architecture from the 2007 foundational disclosure: 3D µPADs (multi-layer paper assembly), electrochemical µPADs (printed electrodes on paper), µPADs with fluorescence detection. Cumulative Whitesides-group µPAD patent filings cover much of the broader paper-microfluidic patent landscape.
“Various Whitesides group µPAD II / III papers”
written · p. 1 · 2010-01-01 · open
President and Fellows of Harvard College (Martinez, Phillips, Carrilho, Whitesides et al.) · openie_prior_art · en
20Whitesides Paper Microfluidics Patent Family (President and Fellows of Harvard College (Martinez, Phillips, Carrilho, Whitesides et al.), 2007-10-12): Harvard/Whitesides paper-microfluidics (microPAD) patent family. Anchors claims around: (a) cellulose paper substrate patterned with hydrophobic barriers (initially photoresist, then wax) defining hydrophilic channels for capillary fluid flow; (b) multi-zone paper devices with sample, reaction, and detection regions; (c) colori
“US7882415B2 USPTO grant text”
written · p. 1 · 2007-01-01 · open
Paul Yager group, University of Washington (with PATH / Micronics) · openie_prior_art · en
21Yager 2006 microfluidic diagnostic technologies for global public health (Paul Yager group, University of Washington (with PATH / Micronics), 2006-07-27): The seminal review of microfluidic diagnostics for the developing world: it lays out the design constraints for instrument-free, low-power, low-cost point-of-care testing (the ASSURED criteria), surveys laminate, paper, and capillary-driven cartridge architectures, and presents diffusion-based assay primitives (H-filter, T-
“Nature 2006, 442, 412-418”
written · p. 1 · 2006-01-01 · open
Thomas Young; Pierre-Simon Laplace · openie_prior_art · en
22Young-Laplace Equation (combined 1805-1806) (Thomas Young; Pierre-Simon Laplace, 1806): Combined Young-Laplace equation is the single most invoked classical result in microfluidic device design: every droplet generator, every capillary-driven assay, every paper-microfluidic device, and every surface-energy patterned channel inherits its quantitative behavior from this equation. As a unified prior-art anchor, the combined equation invalidates broad patents claiming 'surface-te
“Phil. Trans. R. Soc. 95, 65-87 (1805)”
written · p. 1 · 1806-01-01 · open
3M Food Safety (acquired by Neogen 2022) · openie_prior_art · en
233M (now Neogen) Petrifilm food microbiology plates (3M Food Safety (acquired by Neogen 2022)): 3M (now Neogen) Petrifilm food microbiology plates [Subsystems: fabrication-paper-microfluidics, pump-capillary-passive; CPC: C12Q 1/04, G01N 33/02]
“3M Petrifilm (acquired by Neogen 2022). Various FDA / AOAC approvals.”
written · p. 1 · 2026-05-01 · open
Binax Inc. → Inverness → Alere → Abbott · openie_prior_art · en
24Abbott BinaxNOW rapid antigen test cassette (Binax Inc. → Inverness → Alere → Abbott): Abbott BinaxNOW rapid antigen test cassette [Subsystems: fabrication-paper-microfluidics, pump-capillary-passive; CPC: G01N 33/543]
“Abbott BinaxNOW product family (originally Binax Inc., acquired by Inverness/Alere then Abbott). FDA EUA December 2020 for COVID-19 antigen.”
written · p. 1 · 2026-05-01 · open
Abbott Diagnostics · openie_prior_art · en
25Abbott BinaxNOW COVID-19 Antigen Self Test (OTC) (Abbott Diagnostics): Abbott BinaxNOW COVID-19 Antigen Self Test (OTC) [Subsystems: pump-capillary-passive, fabrication-paper-microfluidics, material-paper-cellulose; CPC: G01N 33/558, B01L 3/502]
“Abbott BinaxNOW Antigen Self Test FDA EUA 2021-03-31; product user manual”
written · p. 1 · 2026-05-01 · open
Abbott Diabetes Care · openie_prior_art · en
26Abbott FreeStyle Libre continuous glucose monitor (Abbott Diabetes Care): Abbott FreeStyle Libre continuous glucose monitor [Subsystems: detection-electrochemical-on-chip, pump-capillary-passive; CPC: A61B 5/145, G01N 27/26]
“Abbott FreeStyle Libre system; FDA approval 2017 (US); product literature. https://www.freestyle.abbott”
written · p. 1 · 2026-05-01 · open
Abbott Diabetes Care · openie_prior_art · en
27Abbott FreeStyle Navigator Continuous Glucose Monitor (Abbott Diabetes Care): Abbott FreeStyle Navigator Continuous Glucose Monitor [Subsystems: pump-capillary-passive, detection-electrochemical-on-chip, surface-functionalization-thiol-gold; CPC: A61B 5/14532, C12Q 1/006]
“FDA PMA P050020 March 12 2008; Abbott press release 2008”
written · p. 1 · 2026-05-01 · open
Abionic SA (EPFL spinout) · openie_prior_art · en
28Abionic abioSCOPE Nanofluidic Capillary Immunoassay Cartridge (Abionic SA (EPFL spinout)): Abionic abioSCOPE Nanofluidic Capillary Immunoassay Cartridge [Subsystems: pump-capillary-passive, detection-fluorescence-on-chip; CPC: B01L 3/502761, G01N 33/543]
“Andre M et al. Nanofluidic in vitro diagnostic test for sepsis using PSP measurement on abioSCOPE; Abionic SA founded 2010 from EPFL Patrick Aebischer / Nicolas Durand spinout; FDA 510(k) and CE-IVD filings; Hubacher P et al. J Lab Med 2022”
written · p. 1 · 2026-05-01 · open
Accion Systems, Inc. (technology from the MIT Space Propulsion Laboratory, Lozano group) · openie_prior_art · en
29Accion Systems TILE ionic-liquid electrospray thruster (Accion Systems, Inc. (technology from the MIT Space Propulsion Laboratory, Lozano group)): Accion Systems TILE ionic-liquid electrospray thruster [Subsystems: pump-capillary-passive, detection-mass-spec-electrospray-coupled, interface-electrode-integration, fabrication-silicon-drie, architecture-process-analytical-technology; CPC: F03H 1/0075, B05B 5/025, H01J 27/26, B64G 1/405]
“US8324593B2 Iodine-compatible hall effect... (no) - use US8324593 placeholder removed; primary: Lozano & Martinez-Sanchez, Ionic liquid ion sources, J. Colloid Interface Sci. 282, 415 (2005) and US9194379B1 Field emission/ionic liquid elect”
written · p. 1 · 2026-05-01 · open
Achira Labs · openie_prior_art · en
30Achira Labs paper microfluidics patent family (Achira Labs): Achira Labs paper microfluidics patent family [Subsystems: fabrication-paper-microfluidics, pump-capillary-passive; CPC: ]
“Achira Labs Pvt Ltd (Bangalore) IP estate; IN/US/PCT filings 2012-present”
written · p. 1 · 2026-05-01 · open
Parlak O, Salleo A et al. (Stanford) · openie_prior_art · en
31AfaSci-style Wearable Cortisol Sensor (sweat cortisol aptamer wearable, multi-author) (Parlak O, Salleo A et al. (Stanford)): AfaSci-style Wearable Cortisol Sensor (sweat cortisol aptamer wearable, multi-author) [Subsystems: pump-capillary-passive, detection-electrochemical-on-chip, surface-functionalization-thiol-gold; CPC: A61B 5/145]
“Parlak O et al. Sci Adv 4(7):eaar2904 2018 doi:10.1126/sciadv.aar2904 (molecularly selective electrochemical sweat cortisol patch)”
written · p. 1 · 2026-05-01 · open
Aspara Pte Ltd. · openie_prior_art · en
32Aspara CRISPR-based Detection Cartridge (Aspara Pte Ltd.): Aspara CRISPR-based Detection Cartridge [Subsystems: pump-capillary-passive, thermal-isothermal-amplification, fabrication-thermoplastic-injection-molding, architecture-stat-test-cartridge; CPC: C12Q 1/6883]
“Aspara Pte Ltd. product literature 2022; SG patent application”
written · p. 1 · 2026-05-01 · open
Autobio Diagnostics · openie_prior_art · en
33Autobio Diagnostics rapid test cartridge family (Autobio Diagnostics): Autobio Diagnostics rapid test cartridge family [Subsystems: fabrication-paper-microfluidics, pump-capillary-passive; CPC: G01N 33/543]
“Autobio Diagnostics Co. https://www.autobio.com.cn”
written · p. 1 · 2026-05-01 · open
Becton, Dickinson and Company · openie_prior_art · en
34BD Veritor System cartridge (Becton, Dickinson and Company): BD Veritor System cartridge [Subsystems: fabrication-paper-microfluidics, pump-capillary-passive; CPC: G01N 33/543]
“BD Veritor System product family. https://www.bd.com”
written · p. 1 · 2026-05-01 · open
Becton, Dickinson and Company · openie_prior_art · en
35BD Veritor Plus 2024 - Connected respiratory cartridge (Becton, Dickinson and Company): BD Veritor Plus 2024 - Connected respiratory cartridge [Subsystems: pump-capillary-passive, detection-fluorescence-on-chip, separation-affinity-capture; CPC: G01N 33/558, C12Q 1/6886]
“Becton Dickinson BD Veritor Plus Flu+COVID-19+RSV multiplex cartridge launch 2024.”
written · p. 1 · 2024-01-01 · open
Becton Dickinson · openie_prior_art · en
36BD Veritor rapid test platform (Becton Dickinson): BD Veritor rapid test platform [Subsystems: fabrication-paper-microfluidics, pump-capillary-passive; CPC: G01N 33/543]
“Becton Dickinson BD Veritor System. https://www.bd.com”
written · p. 1 · 2026-05-01 · open
David J. Beebe group, University of Wisconsin-Madison · openie_prior_art · en
37Berthier and Beebe 2007 flow rate analysis of a surface-tension-driven passive micropump (David J. Beebe group, University of Wisconsin-Madison): Berthier and Beebe 2007 flow rate analysis of a surface-tension-driven passive micropump [Subsystems: fabrication-thermoplastic-injection-molding, pump-capillary-passive, pump-pressure-controlled-air-over-liquid; CPC: F04B 19/00, B01L 3/00, B01L 3/502]
“Berthier, E.; Beebe, D. J. Flow rate analysis of a surface tension driven passive micropump. Lab Chip 2007, 7, 1475-1478. DOI: 10.1039/b707637a”
written · p. 1 · 2007-01-01 · open
Biolinq Inc. (formerly Electrozyme) · openie_prior_art · en
38Biolinq Intradermal Microneedle CGM Patch (Biolinq Inc. (formerly Electrozyme)): Biolinq Intradermal Microneedle CGM Patch [Subsystems: pump-capillary-passive, detection-electrochemical-on-chip, fabrication-silicon-drie, surface-functionalization-thiol-gold, architecture-multiplex-cartridge; CPC: A61B 5/14532, A61M 37/0015]
“Biolinq Inc. corporate disclosures; clinical trial NCT04790344 2021; Krishnan SR et al. for Biolinq founder publications”
written · p. 1 · 2026-05-01 · open
Lorand Eoetvoes (1886); Wilfrid Noel Bond (1928 dimensionless form) · openie_prior_art · en
39Bond / Eoetvoes Number Bo = rho g L^2 / gamma (Lorand Eoetvoes (1886); Wilfrid Noel Bond (1928 dimensionless form)): Bond / Eoetvoes Number Bo = rho g L^2 / gamma [Subsystems: pump-capillary-passive, valve-capillary-stop; CPC: B01L 3/502]
“Eoetvoes, R. (1886). 'Ueber den Zusammenhang der Oberflaechenspannung der Fluessigkeiten mit ihrem Molekularvolumen.' Annalen der Physik 263(3): 448-459. doi:10.1002/andp.18862630309. Bond, W. N. (1928). Proc. Phys. Soc. 41, 1.”
written · p. 1 · 2026-05-01 · open
Busek Co. Inc. · openie_prior_art · en
40Busek BET ionic-liquid electrospray micro-thruster (BET-MAX / BET-100) (Busek Co. Inc.): Busek BET ionic-liquid electrospray micro-thruster (BET-MAX / BET-100) [Subsystems: pump-capillary-passive, pump-piezoelectric-stack, valve-check, detection-mass-spec-electrospray-coupled, interface-electrode-integration; CPC: F03H 1/0075, B05B 5/025, B64G 1/405, H01J 27/26]
“Ziemer et al., Colloid micro-newton thrust development for the LISA Pathfinder mission, AIAA 2006 / Joint Propulsion Conference; see also US7872848B2 Method of operating a colloid thruster (Busek Co. Inc.).”
written · p. 1 · 2026-05-01 · open
Capitainer AB (KTH Royal Institute of Technology spinout, Niclas Roxhed group) · openie_prior_art · en
41Capitainer qDBS Quantitative Dried Blood Spot Microfluidic Card (Capitainer AB (KTH Royal Institute of Technology spinout, Niclas Roxhed group)): Capitainer qDBS Quantitative Dried Blood Spot Microfluidic Card [Subsystems: pump-capillary-passive, valve-capillary-stop, architecture-stat-test-cartridge; CPC: A61B 5/15]
“Lenk G, Sandkvist S, Pohanka A, Stemme G, Beck O, Roxhed N. A disposable sampling device to collect volume-measured DBS directly from a fingerprick onto DBS paper. Bioanalysis 2015; Capitainer AB founded 2014 (KTH spinout).”
written · p. 1 · 2026-05-01 · open
ChemBio Diagnostic Systems · openie_prior_art · en
42ChemBio Diagnostics DPP (Dual Path Platform) lateral-flow (ChemBio Diagnostic Systems): ChemBio Diagnostics DPP (Dual Path Platform) lateral-flow [Subsystems: fabrication-paper-microfluidics, pump-capillary-passive; CPC: G01N 33/543]
“ChemBio Diagnostic Systems DPP product family. https://chembio.com”
written · p. 1 · 2026-05-01 · open
SPD Swiss Precision Diagnostics GmbH (Procter & Gamble / Abbott JV) · openie_prior_art · en
43Clearblue Connected Digital Pregnancy Test (Bluetooth) (SPD Swiss Precision Diagnostics GmbH (Procter & Gamble / Abbott JV)): Clearblue Connected Digital Pregnancy Test (Bluetooth) [Subsystems: pump-capillary-passive, detection-fluorescence-on-chip, fabrication-paper-microfluidics, material-paper-cellulose; CPC: G01N 33/76, G01N 33/558]
“SPD Swiss Precision Diagnostics product launch 2021; Clearblue Connected technical brochure”
written · p. 1 · 2026-05-01 · open
Raphael Consden, Archer Gordon, Archer Martin (Wool Industries Research Association / Lister Institute) · openie_prior_art · en
44Paper partition chromatography (Raphael Consden, Archer Gordon, Archer Martin (Wool Industries Research Association / Lister Institute)): Paper partition chromatography [Subsystems: fabrication-paper-microfluidics, pump-capillary-passive, separation-partition-chromatography; CPC: B01L 3/5023, G01N 30/90, B01D 15/10]
“Consden, R.; Gordon, A. H.; Martin, A. J. P. Qualitative analysis of proteins: a partition chromatographic method using paper. Biochem. J. 1944, 38, 224-232. DOI: 10.1042/bj0380224”
written · p. 1 · 2026-05-01 · open
Henry Darcy · openie_prior_art · en
45Darcy 1856 - Les Fontaines Publiques de la Ville de Dijon (Darcy's law) (Henry Darcy): Darcy 1856 - Les Fontaines Publiques de la Ville de Dijon (Darcy's law) [Subsystems: pump-capillary-passive, fabrication-paper-microfluidics, material-paper-cellulose, separation-membrane-filtration-on-chip; CPC: B01L 3/502, G01N 33/52, B01D 39/00]
“Darcy, H. (1856). 'Les Fontaines Publiques de la Ville de Dijon.' Victor Dalmont, Paris. Appendix D: filtration experiments.”
written · p. 1 · 1856-01-01 · open
Detect Inc. · openie_prior_art · en
46Detect Inc. COVID-19 RT-LAMP Cartridge (Detect Inc.): Detect Inc. COVID-19 RT-LAMP Cartridge [Subsystems: pump-capillary-passive, valve-burst-frangible, thermal-isothermal-amplification, thermal-on-chip-resistive-heater, interface-blister-pack-reagent-storage, detection-fluorescence-on-chip; CPC: C12Q 1/6883, B01L 3/502]
“Detect Inc. FDA EUA 2021-10-29 (originally Homodyne Health); product user manual rev 2”
written · p. 1 · 2026-05-01 · open
Detect, Inc. · openie_prior_art · en
47Detect Inc. Flu + COVID 2024 extend (Detect, Inc.): Detect Inc. Flu + COVID 2024 extend [Subsystems: thermal-isothermal-amplification, detection-fluorescence-on-chip, pump-capillary-passive; CPC: B01L 7/52, C12Q 1/6886]
“Detect Inc. Flu+COVID-19 RT-LAMP cartridge product update 2024.”
written · p. 1 · 2024-01-01 · open
Dexcom Inc. · openie_prior_art · en
48Dexcom G5 Mobile Continuous Glucose Monitor (Dexcom Inc.): Dexcom G5 Mobile Continuous Glucose Monitor [Subsystems: pump-capillary-passive, detection-electrochemical-on-chip, surface-protein-passivation; CPC: A61B 5/14532]
“FDA PMA P120005/S041 supplement August 2015; Dexcom press release 2015-08-24”
written · p. 1 · 2026-05-01 · open
Dexcom Inc. · openie_prior_art · en
49Dexcom G6 Continuous Glucose Monitor (Dexcom Inc.): Dexcom G6 Continuous Glucose Monitor [Subsystems: pump-capillary-passive, detection-electrochemical-on-chip, interface-blister-pack-reagent-storage, surface-protein-passivation, architecture-stat-test-cartridge; CPC: A61B 5/14532, A61B 5/1486]
“FDA 510(k) clearance DEN170088 (Dexcom G6, March 27 2018); Dexcom press release March 27 2018; US patent 9,724,025 (in vivo glucose sensor)”
written · p. 1 · 2026-05-01 · open
Dexcom Inc. · openie_prior_art · en
50Dexcom Stelo Glucose Biosensor System (Dexcom Inc.): Dexcom Stelo Glucose Biosensor System [Subsystems: pump-capillary-passive, detection-electrochemical-on-chip, architecture-stat-test-cartridge; CPC: A61B 5/14532]
“FDA De Novo DEN230071 March 5 2024 (first OTC CGM clearance); Dexcom press release 2024-03-05”
written · p. 1 · 2026-05-01 · open

showing 1–50 of 128next →